Approaches Tabs
ere is one sub-tab for each approach under the main Approaches tab. Each
enabled variable for the specied approach will qualify an interval if the de-
tected value exceeds the set threshold.
˽Over Speed – qualies if average speed is above set threshold
˽Under Speed – qualies if average speed is below set threshold
˽Over Occupancy – qualies if occupancy is above set threshold
˽Under Occupancy – qualies if occupancy is below set threshold
˽Over Volume – qualies if total volume is above set threshold
˽Under Volume – qualies if total volume is below set threshold
8Run mode
9Reset
To reset the Click 513, follow the steps below:
1 Hold the push-button down, then release when the red LED starts ashing.
2 Press the push-button to select. e rst yellow LED will turn on to let you use that submenu.
3 Hold down the push button again to cycle between the following options:
˽Yellow 1 – Resets all settings except Serial Number and XML variable map
˽Yellow 2 – Resets all settings except Serial Number
4 Release when you reach the one you want. Press the push-button to select.
Aer the device is reset, it will return to the last mode that it was in.
Once the device has been congured, set it to Run mode to start retrieving trac data.
1 Hold the push-button down, then release when the blue LED turns on.
2 Press the push-button to select. e red and blue lights will turn on, and the yellow light will ash as
data is received.
In run mode the Click 513 polls data from the SmartSensor HD on the RS-485 T-bus port and compares the
detected values to the thresholds set in Click Supervisor. You can use a serial terminal program to view text
status information on your computer.
Note. e Click 513 communicates at 9600 bps.
Output Tab
˽Time Zone – Allows you to select the appropri-
ate time zone.
˽Morning/Afternoon Start/Stop Time – Begin-
ning and end times that the alerts will operate to
turn on/o during the morning/aernoon hours.
Lanes Tab
ere is one sub-tab for each lane under the main
Lanes tab. Each enabled variable for the specied
approach will qualify an interval if the detected value
exceeds the set threshold. e settings are the same as
the Approaches tab.