WG Pro-Guard Bedienungsanleitung

58Khz
Pro-GuardTM & Uni-GuardTM
Instruction Manual
[24vac Low Voltage with 110.220vac Transformer]
Version 2004 April
Manual Part Number: WG-PRG-IM
(042004A)
WG SECURITY PRODUCTS INC.
3031 Tisch Way, Suite 602, San Jose, CA 95128 (USA)
http://www.wgspi.com

TECHNICAL SUPPORT CONTACT INFORMATION
North America
South America
Tel: 818-763-9186
Fax: 818-255-0514
Rest of World
Tel: 408-241-8000
Fax: 408-241-8082
Email: support@wgspi.com
WARRANTY DISCLAIMER
WG Security Product Inc. makes no representation o
r
warranty with respect to the contents hereof and
specifically disclaims any implied warranties o
f
merchantability or fitness for any particular purpose.
Further, WG Security Product Inc. reserves the right to
revise this publication and make changes from time to
time in the content hereof without obligation of WG
Security Product Inc. to notify any person of such
revision or changes.
Important Notice!
Due to regulations of FCC 15.21, any changes o
r
modifications not expressly approved by the party
responsible for compliance will void the user's
authority to operate the equipment.

TABLE OF CONTENTS
CHAPTER ONE ........................................................................................... 1
System Overview .............................................................................................. 1
Features & Benefits .......................................................................................... 2
Pro-Guard System Parts List ............................................................................ 3
Uni-Guard System Parts List ............................................................................ 4
CHAPTER TWO........................................................................................... 5
Installation Procedures ..................................................................................... 5
Step-Down Transformer Box......................................................................... 5
Transformer Cable Connection..................................................................... 6
Step-Down Transformer Capacity................................................................. 6
System Connections (Pro-Guard & Uni-Guard)............................................ 7
Optional Power Connection for Pro-Guard ................................................... 8
Optional Split System Connection for Pro-Guard (two Tx’s & one Rx) ........ 9
Optional IR Counting System Configuration (Pro-Guard & Uni-Guard) ..... 10
Power Cord Notices ........................................................................................ 11
North American Power Supply Cords ......................................................... 11
International Power Supply Cord ................................................................ 11
Fuse Replacement Information....................................................................... 16
IR Control Keyboard Function Description & Default Parameters Table ....... 19
Tuning Procedures & Tips .............................................................................. 21
Remote Control Programming ........................................................................ 22


Pro-Guard & Uni-Guard Installation Manual
1
CHAPTER ONE
System Overview
Pro-Guard and Uni-Guard Electronic Article Surveillance systems operate with any 58Khz
acousto-magnetic tag. Both systems are plug-and-play, eliminating the need for expensive
technicians. Pro-Guard is a dual pedestal system whereas Uni-Guard is a single pedestal
transceiver system.
The fully digital Pro-Guard and Uni-Guard systems are today’s most technically advanced
58Khz pedestal systems on the market. Both systems are fully digital, software driven, and
have the latest DSP technology that constantly checks the environment, eliminating false
alarms that are common with competing systems.
Technical Data Europe USA
Height 1470mm 58”
Width 710mm 28”
Thickness 120mm 7.1”
Weight 10Kg 22lbs
Power 220-240vac 100-120vac
Operating Frequency 58Khz 58Khz
Micro Pencil Tag Detection 2.6 meters 9 feet
Operating Temperature 0º C to 30º C 32º F to 86º F
9 Feet (2.6m)

Pro-Guard & Uni-Guard Installation Manual
2
Technical Data Europe USA
Height 1470mm 58”
Width 710mm 28”
Thickness 120mm 7.1”
Weight 10Kg 22lbs
Power 220-240vac 100-120vac
Operating Frequency 58Khz 58Khz
Micro Pencil Tag Detection 1.2 meters on
either side.
4 feet on either
side.
Operating Temperature 0º C to 49º C 32º F to 120º F
Features & Benefits
• Self tuning electronics
• Software driven
• Network Access for remote tuning
• Built-in alarm
• Port for driving an external alarm
• Constructed of strong, light ABS fire retardant molding
• Compatible with all 58Khz acousto-magnetic labels and hard tags.
• Greater detection in all tag orientations
4 Feet (1.2m) 4 Feet (1.2m)

Pro-Guard & Uni-Guard Installation Manual
3
Pro-Guard System Parts List
Part Name Order Number
1 Transmitter Pedestal WG-PRG-PC-T
2 Receiver Pedestal WG-PRG-PC-R
3 Clear Alarm Cover WG-PRG-WD
4 Base WG-PRG-BS
5 Remote Control WG-MG-RC OLD
6 Interconnection Connector WG-MG-ICC
7 Pedestal Power Cable
Connector
WG-PRG-PLC
8 Installation Tool WG-MG-IT
9 Field Indicator Pen WG-MG-FP
10 Interconnection Line WG-MG-CC
11 Instruction Manual WG-PRG-M
12 24vac Transformer WG-PRG-TR
Base (2)
Pedestal Power Cable & Connector (2)
Transformer Primary Power Cable (1)
Installation Tool (1)
Clear Alarm Cover
24vac
Transformer (1)
Remote Control (1)
Bolts (8)
Transmitter & Receiver
Pedestals (2)
Interconnection Line
& Connector (2)

Pro-Guard & Uni-Guard Installation Manual
4
Uni-Guard System Parts List
Part Name Order Number
1 Transceiver Pedestal WG-UNG-PC
2 Clear Alarm Cover WG-PRG-WD
3 Base WG-PRG-BS
4 Remote Control WG-MG-RC OLD
5 Pedestal Power Cable
Connector
WG-PRG-PLC
6 Installation Tool WG-MG-IT
7 Field Indicator Pen WG-MG-FP
8 Instruction Manual WG-PRG-M
9 24vac Transformer WG-PRG-TR
10 IR Mirror Reflector WG-UNG-MIR
Base (1) Pedestal Power Cable & Connector (1)
Transformer Primary Power Cable (1)
Installation Tool (1)
Clear Alarm Cover
24vac
Transformer (1)
Remote Control (1)
Bolts (4)
IR Mirror
Reflector (1)
Pedestal
Transceiver (1)

Pro-Guard & Uni-Guard Installation Manual
5
CHAPTER TWO
Installation Procedures
Step-Down Transformer Box
Fuse replacement
Extend fuse (time-delay fuse)
5mmx20mm 3.15A
Equipment shall be electrically disconnected from
the branch-circuit supply when replacing the fuse.
WARNING - TO REDUCE THE RISK OF DAMAGE. REPLACE
ONLY WITH SAME TYPE AND RATING OF FUSE.
OFF
ON
VOLTAGE SWITCH
AC POWER
24VAC OUTPUT 2
0V GND 24V0V GND 24V
24VAC OUTPUT 1
Caution:
The Voltage Switch is used to set the
system for the appropriate AC input.
North America – Set the switch to 115.
Europe – Set the switch to 230.

Pro-Guard & Uni-Guard Installation Manual
6
Transformer Cable Connection
Connect the three pins of the power connector to the corresponding terminals of the
transformer connector. The ground pins from both must be connected, but the 0V and 24V
terminals from the step-down transformer can be swapped to change the polarity of the
system.
3-Pin Power Connector Layout 3-Terminal Transformer
Connector Layout
Pin Function Color Pin Function Color
1 “N or L“ *Blue/Brown 1 0V Blue/Brown
2 Ground Green w/Yellow Stripe 2 Ground Green w/Yellow Stripe
3 “L or N” *Brown/Blue 3 24V Brown/Blue
(180 degrees phase switch)
* Note: Pin 1 and Pin 3 of the power connector are equivalent to former N and L
terminals for 110/220vac systems. Switching them will switch the system’s phase 180
degrees; same as former 110/220vac systems.
Step-Down Transformer Capacity
• Pro-Guard: Maximum 1 Transformer per Transmitter/Receiver pair.
• Uni-Guard: Maximum 1 Transformer per Uni-Guard.
Red
Green
Blue
Pin 1
24VAC OUTPUT
0V GND 24V
Pin 1
Brown
3-Pin Power Connector Transformer 24V Output Terminal
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung