33740-11-0816Page 4
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
,QVWDOOHUPXVWKDYHRZQHU¿OORXWDQGPDLOZDUUDQW\FDUGVXSSOLHG
ZLWKWKH¿UHSODFH
3. Installer should show owner how to start and operate the
¿UHSODFH
7KLV GLUHFW YHQW JDV ¿UHSODFH LV GHVLJQHG WR RSHUDWH ZLWK DOO
combustion air being siphoned from the outside of the building
and all exhaust gases expelled to the outside of the building. The
information contained in this manual pertains to all models and gas
control systems unless otherwise noted.
$SSOLDQFH&HUWL¿FDWLRQ
WARNING
This unit is not for use with solid fuels.
7KLV¿UHSODFHLVGHVLJQFHUWL¿HGLQDFFRUGDQFHZLWK$PHULFDQ
1DWLRQDO6WDQGDUG$16,=DQGE\8QGHUZULWHUV/DERUDWRULHV
as a Direct Vent Gas Fireplace and shall be installed according to
these instructions.
Consultyourlocalbuildingcodeagency,priortoinstallation,toensure
compliance with local codes-including permits and inspections.
7KH ¿UHSODFH ZKHQ LQVWDOOHG PXVW EH HOHFWULFDOO\ JURXQGHG LQ
accordance with local codes or, in absence of local codes, with
the National Electric Code ANSI/NFPA 70, if an external electrical
source is utilized.
These models may be installed in a bedroom or bed-sitting room
in the U.S.A..
4XDOL¿HG,QVWDOOLQJ$JHQF\
Installationandreplacementofgaspiping,gasutilizationequipment
or accessories and repair and servicing of equipment shall be
SHUIRUPHGRQO\E\DTXDOL¿HGDJHQF\7KHWHUP³TXDOL¿HGDJHQF\´
PHDQVDQ\LQGLYLGXDO¿UPFRUSRUDWLRQRUFRPSDQ\ZKLFKHLWKHULQ
personorthrougharepresentativeisengagedinandisresponsiblefor
(a)theinstallationorreplacementofgaspipingor(b)theconnection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made
E\DOLFHQVHGSOXPEHURUJDV¿WWHULQWKH&RPPRQZHDOWKRI
Massachusetts.
WARNING
ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS
CAN BE DANGEROUS.
,PSURSHULQVWDOODWLRQRUXVHRIWKH¿UHSODFHFDQFDXVHVHULRXV
LQMXU\RUGHDWKIURP¿UHEXUQVH[SORVLRQVRUFDUERQPRQR[LGH
poisoning.
The installation must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA
54* Natural Gas and Propane Installation Code *Available from the
American National Standards Institute, Inc. 11 West 42nd St., New
York, N.Y. 10036.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
High Altitude
:KHQLQVWDOOLQJWKLVXQLW DW DQ HOHYDWLRQ DERYH IHHW LQ WKH
United States) it may be necessary to decrease the input rating by
FKDQJLQJWKH H[LVWLQJ EXUQHU RUL¿FHWRDVPDOOHU VL]H *HQHUDOO\
LQSXWVKRXOGEHUHGXFHGSHUFHQWIRUHDFKIHHWDERYHVHD
level. However, if the heating value of the gas has been reduced,
thisgeneralrulemaynotapply.CheckwithEmpireComfortSystems
IRUSURSHURUL¿FHVL]HLGHQWL¿FDWLRQ
Preparation
7KLVGLUHFWYHQWJDV¿UHSODFHDQGLWVFRPSRQHQWVDUHWHVWHGDQG
safe when installed in accordance with this Installation Manual.
5HSRUWWR\RXUGHDOHUDQ\SDUWVGDPDJHGLQVKLSPHQWVSHFL¿FDOO\
checkglasscondition.Donotinstallunitwithdamaged,incomplete,
or substitute parts. Read all instructions before starting installation
and follow these instructions carefully during installation to insure
PD[LPXPEHQH¿WDQGVDIHW\)DLOXUHWRIROORZWKHPZLOOYRLG\RXU
ZDUUDQW\DQGPD\SUHVHQWD¿UHKD]DUG
The warranty will be voided by, and the warranter disclaims any
responsibility for the following actions:
,QVWDOODWLRQRIDQ\GDPDJHG¿UHSODFHRUYHQWV\VWHPFRPSRQHQW
0RGL¿FDWLRQRIWKH¿UHSODFHRUGLUHFWYHQWV\VWHP
,QVWDOODWLRQRWKHUWKDQDVLQVWUXFWHGE\(PSLUH&RPIRUW6\VWHPV
Inc.
,PSURSHUSRVLWLRQLQJRIORJVRUHPEHUV
,QVWDOODWLRQDQGRUXVHRIDQ\FRPSRQHQWSDUWQRWPDQXIDFWXUHG
or approved by manufacturer.
INTRODUCTION