Portable low-pressure controller, model CPC2000
Portabler Niederdruckcontroller, Typ CPC2000
Contrôleur basse pression portable, type CPC2000
Controlador portátil de bajas presiones, modelo CPC2000
Portable low-pressure controller model CPC2000

2
11155094.02 07/2012 GB/D/F/E
WIKA operating instructions, model CPC2000
GB
D
F
E
© 2012 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA® is a registered trademark in various countries.
WIKA® ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
Operating instructions model CPC2000 Page 3 - 34
Betriebsanleitung Typ CPC2000 Seite 35 - 66
Mode d'emploi type CPC2000 Page 67 - 98
Manual de instrucciones modelo CPC2000 Página 99 - 130

3WIKA operating instructions, model CPC2000
11155094.02 07/2012 GB/D/F/E
GB
Contents
1. General information 4
2. Safety 5
2.1 Intended use 6
2.2 Personnel qualication 6
2.3 Special hazards 7
2.4 Labelling/Safety marks 8
3. Specications 9
4. Design and function 12
4.1 Short description 12
4.2 Scope of delivery 12
4.3 Electrical connections on the rear 12
4.4 Voltage supply 13
4.5 Front display of the CPC2000 13
4.6 Pressure connections 15
4.7 Overpressure protection 15
5. Transport, packaging and storage 16
6. Commissioning, operation 17
6.1 Operating mode 'Control' (CTRL) 17
6.2 Operating mode 'Measure' (MEAS) 18
6.3 Operating mode 'AUTO' 20
6.4 Leakage (LEAK) 22
6.5 SETUP settings (SETUP) 23
7. Interface 25
7.1 USB interface 25
7.2 RS-232 Interface 25
7.3 Interface conguration 25
7.4 Commands for serial interface 26
7.5 Driver 28
8. Maintenance, cleaning and service (recalibration) 29
9. Faults 30
10. Dismounting, return and disposal 30
11. Accessories 32
Appendix 1: EC Declaration of Conformity for model CPC2000 33
Declarations of conformity can be found online at www.wika.com.
Contents

4 WIKA operating instructions, model CPC2000
11155094.02 07/2012 GB/D/F/E
GB
1. General information
1. General information
■
The low-pressure controller described in the operating instructions has been designed
and manufactured using state-of-the-art technology.
All components are subject to stringent quality and environmental criteria during
production. Our management systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the instrument.
Working safely requires that all safety instructions and work instructions are observed.
■
Observe the relevant local accident prevention regulations and general safety regula-
tions for the instrument’s range of use.
■
The operating instructions are part of the product and must be kept in the immediate
vicinity of the instrument and readily accessible to skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the operating instructions
prior to beginning any work.
■
The manufacturer’s liability is void in the case of any damage caused by using the
product contrary to its intended use, non-compliance with these operating instructions,
assignment of insuciently qualied skilled personnel or unauthorised modications to
the instrument.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modications.
■
Factory calibrations / DKD/DAkkS calibrations are carried out in accordance with
international standards.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: CT 27.51
- Application consultant: Tel.: (+49) 9372/132-9986
Fax: (+49) 9372/132-8767
E-mail: [email protected]

5WIKA operating instructions, model CPC2000
11155094.02 07/2012 GB/D/F/E
GB
1. General information / 2. Safety
Explanation of symbols
DANGER!
... indicates a directly dangerous situation resulting in serious injury or
death, if not avoided.
WARNING!
... indicates a potentially dangerous situation that can result in serious
injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries
or damage to equipment or the environment, if not avoided.
Information
... points out useful tips, recommendations and information for ecient and
trouble-free operation.
DANGER!
...identies hazards caused by electric power. Should the safety instruc-
tions not be observed, there is a risk of serious or fatal injury.
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropri-
ate portable low-pressure controller has been selected in terms of measur-
ing range, design and specic measuring conditions.
Non-observance can result in serious injury and/or damage to the equip-
ment.
Further important safety instructions can be found in the individual
chapters of these operating instructions.

6 WIKA operating instructions, model CPC2000
11155094.02 07/2012 GB/D/F/E
GB
2. Safety
2.1 Intended use
The model CPC2000 low-pressure controller is used for testing and calibrating pressure
sensors.
The instrument has been designed and built solely for the intended use described here,
and may only be used accordingly.
The technical specications contained in these operating instructions must be observed.
Improper handling or operation of the instrument outside of its technical specications
requires the instrument to be taken out of service immediately and inspected by an
authorised WIKA service engineer.
Handle electronic precision measuring instruments with the required care (protect from
humidity, impacts, strong magnetic elds, static electricity and extreme temperatures,
do not insert any objects into the instrument or its openings). Plugs and sockets must be
protected from contamination.
If the instrument is transported from a cold into a warm environment, the formation of
condensation may result in instrument malfunction. Before putting it back into operation,
wait for the instrument temperature and the room temperature to equalise.
The manufacturer shall not be liable for claims of any type based on operation contrary to
the intended use.
2.2 Personnel qualication
WARNING!
Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and damage to
equipment.
■
The activities described in these operating instructions may only
be carried out by skilled personnel who have the qualications
described below.
■
Keep unqualied personnel away from hazardous areas.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training,
knowledge of measurement and control technology and on their experience and knowl-
edge of country-specic regulations, current standards and directives, are capable of
carrying out the work described and independently recognising potential hazards.

7WIKA operating instructions, model CPC2000
11155094.02 07/2012 GB/D/F/E
GB
2. Safety
Special operating conditions require further appropriate knowledge, e.g. of aggressive
media.
2.3 Special hazards
WARNING!
Protection from electrostatic discharge (ESD) required.
The proper use of grounded work surfaces and personal wrist straps is
required when working with exposed circuitry (printed circuit boards),
in order to prevent static discharge from damaging sensitive electronic
components.
To ensure safe working on the instrument, the operating company must
ensure
■
that suitable rst-aid equipment is available and aid is provided
whenever required.
■
that the operating personnel are regularly instructed in all topics
regarding work safety, rst aid and environmental protection and
knows the operating instructions and, in particular, the safety instruc-
tions contained therein.
DANGER!
Danger of death caused by electric current
Upon contact with live parts, there is a direct danger of death.
Operation using a defective power supply unit (e.g. short circuit from the
mains voltage to the output voltage) can result in life-threatening voltag-
es at the instrument!
WARNING!
Residual media on the dismounted low-pressure controller can result
in a risk to persons, the environment and the equipment. Take sucient
precautionary measures.
Do not use this instrument in safety or Emergency Stop devices. Incor-
rect use of the instrument can result in injury.
Should a failure occur, aggressive media with extremely high tempera-
ture and under high pressure or vacuum may be present at the instru-
ment.
Pmax = 1 bar atmospheric pressure

8 WIKA operating instructions, model CPC2000
11155094.02 07/2012 GB/D/F/E
GB
2. Safety
2.4.2 Explanation of symbols
Before mounting and commissioning the instrument, ensure you read the
operating instructions!
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European
directives.
This marking on the instruments indicates that they must not be disposed
of in domestic waste. The disposal is carried out by return to the manufac-
turer or by the corresponding municipal authorities (see directive 2002/96/
EC).
2.4 Labelling/Safety marks
2.4.1 Product label
For an explanation of symbols,
see below
Power supply
Pressure medium
Operating temperature
Pressure range
Accuracy
Year of manufacture

9WIKA operating instructions, model CPC2000
11155094.02 07/2012 GB/D/F/E
GB
3. Specications
3. Specications
Reference pressure sensors
Pressure range mbar 1 10 50 100 500 1,000
Accuracy % FS 0.3 0.1 0.1 0.1 0.1 0.1
Type of pressure Positive or negative gauge pressure or dierential pressure
Pressure units Pa, kPa, hPa, bar, mbar, psi, inH2O, inHg, mmHg, Torr
Base instrument
Instrument
Instrument version desktop instrument with carry handle
Dimensions 102.6 x 257 x 271 mm without carry handle
Weight 4.6 kg
Ingress protection IP 20
Pressure generation internal, electric pump
Display
Screen backlit, multiline graphic display
Resolution 5 (4 digits for 50/500 mbar measuring range)
Keyboard Membrane keypad
Menu language German, English, Spanish and French
Connections
Pressure connections 6.6 x 11 (hose diameter, D = 6 mm)
Wetted parts Ni, Al, CuBe, PU
Voltage supply
Power supply DC 24 V, 1 A
Power consumption 24 VA
Battery type Li-Ion
Battery life approx. 8 h
Permissible ambient conditions
Media Ambient air
Operating temperature 10 ... 40 °C
Storage temperature -10 ... +70 °C
Relative humidity 30 ... 80 % r. h. (non-condensing)

10 WIKA operating instructions, model CPC2000
11155094.02 07/2012 GB/D/F/E
GB
3. Specications
Base instrument
Control parameter
Control steps 0 ... 50 % individually adjustable or 100 %
Control rate approx. 5 s (dependent upon test volume)
Communication
Interface RS-232 and USB
Response time 1 value/s
Zero point adjustment automatic (at denable time intervals)
manual (ZERO button)
Approvals and certicates
CE conformity
EMC directive 2004/108/EC, EN 61000-6-3, emissions for residential, commer-
cial and light-industrial environments and EN 61000-6-2, interfer-
ence immunity for industrial environments
Certicate
Calibration 1) incl. 3.1 calibration certicate per EN 10204
1) Calibration in a horizontal position.
For further specications see WIKA data sheet CT 27.51 and the order documentation.
Andere Handbücher für MENSOR CPC 2000
1
Inhaltsverzeichnis
Sprachen:
Andere WIKA Controller Handbücher

WIKA
WIKA SC Series Bedienungsanleitung

WIKA
WIKA CS 3 S Bedienungsanleitung

WIKA
WIKA A2G-100 Bedienungsanleitung

WIKA
WIKA CPC8000 Bedienungsanleitung

WIKA
WIKA CPC3000 Bedienungsanleitung

WIKA
WIKA CPC7000 Bedienungsanleitung

WIKA
WIKA CS4R Bedienungsanleitung

WIKA
WIKA CS4H Bedienungsanleitung

WIKA
WIKA MENSOR CPC 2000 Bedienungsanleitung

WIKA
WIKA CPC8000-H Bedienungsanleitung