Woodbridge V8300 Bedienungsanleitung

Thank you for choosing our products.Please read the instructions carefully before installation and
keep it available for future maintenance or reference.
ELECTRONIC TOILET SEAT

Important Safeguards
Technical specification
List of materials
Technical drawings
Parts identification
Installation of ceramic toilet
Previous preparation
Daily maintenance
1.Main unit care and maintenace
2.Spray nozzle maintenance and care
Emergency troubleshooting
1.Electricity and water supply cut-off
2.Failure of remote control
3.When the product is left unused for long time
Function keys description
Troubleshooting Guide
Warranty Card
01
03
05
06
07
08
10
11
12
14
15
16
Maintenance Others
Installation
Content

01
IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USING
When using electrical products, especially when children are present, basic safety
precautions should always be followed, including the following:
1.The appliance is not to be used by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction.
2.Children being supervised not to play with the appliance.
3.This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved.
4.Children shall not play with the appliance.
5.Cleaning and user maintenance shall not be made by children without supervision.
DANGER–To reduce the risk of electrocution:
1. Do not use while bathing.
3. Do not place in or drop into water or other liquid.
4. Do not reach for a product that has fallen into water. Unplug immediately.
5. Do not wash the main unit or electrical plug with water or detergent.
6. Do not handle the electrical plug with wet hands.
7. Do not put a hand or other staff over the outlet of air dryer or block the outlet of air dryer.
8. Never disassemble,repair or modify this product.
9. During installation, disassembly, repaire and maintenance of the product,the power plug
must be switched off and water supply be shut off.
WARNING–To reduce the risk of burns, electrocution, fire, or injury to persons.
1. Close supervision is necessary when this product is used by, on, or near children or
invalids.
2. Use this product only for its intended use as described in this manual. Do not use
attachments not recommended by the manufacturer.
3. Never operate this product if it has a damaged cord or plug, if it is not working properly,
if it has been dropped or damaged, or dropped into water. Return the product to a
service center for examination and repair.
4. Keep the cord away from heated surfaces.
5. Never use while sleeping or drowsy.
6. Never drop or insert any object into any opening or hose.
7. Do not use outdoors or operate where aerosol (spray) products are being used or
where oxygen is being administered.
8. Connect this product to a properly grounded outlet only. See Grounding Instructions.
9. Do not throw cigarettes and other burning stuff into toilet, otherwise it might cause fire.
10.This product is electric appliance, so it must be placed far away from water. Please
don’t drench urine and other liquid to it.
11.Do not lay on side or upside the product during the electrical circuit.
12.It is prohibited to use other electric appliances in the same socket.
13.It is forbidden to use the power extension or unstable loose outlet.
14.The old aging water supply hose can not be used, otherwise it might cause leakage,
fire or electrical shock.Installation of the bidet seat should include specified components
and new water supply hose.
2. Do not place or store product where it can fall or be pulled into a tub or sink.

02
IMPORTANT SAFETY INSTRUCTIONS
1. Do not install or use the product in wet places as steam room etc.
2. It is recommended to use water-proof electrical outlet which should be lnstalled in the place
where is not easily got wet.
3. This product should be used with 110V-120V,50/60Hz electrical current only,load current
is at least 15A. Power plug must be equipped with ground fault circuit interrupter or ground
fault electrical leakage protector or similar high sensitive, rapid type leakage switch
(Rated sensitive current under 6mA).
4. When it thunders,it is strongly recommended to pull out the power plug.
5. Do not stand on ceramic toilet.
6. Ceramic toilet must install floor fixing bolt.
7. Do not stand on product unit,seat and cover.
8. Do not lean against the seat cover when using the product,to avoid damage.
9. This product is equipped with soft-closing seal cover.Heavy pressing or pushing may damage
the soft-closing damper.
10. Do not use lacquer thinner,petrol,liquid medicine,detergent,insecticide,toilet cleanser and
scrubbing brush to clean the product.
11.Exposure to direct sunlight is prohibited.
12.Only use tap water or potable water;otherwise it may cause chafing.
13.Do not connect water supply to heater outlet.Make sure inlet water temperature at
3~35℃
14.When the room temperature is under zero degree,please dry up the water tank,to avoid
freezing.
15.Raise rest room temperature to prevent the toilet from damage due to freezing.
16.When move the product from cold or wet environment into normal room temperature,wait for
2 hours until the condensation water is fully volatilized.Doing so can prevent the product from
electrical short-circuit.
17.When not using the product over three(3) days,drain the water out of the container and pull
the electrical plug from the wall outlet.
18.Stop using the product and shut off the power when product malfunctions,please contact the
service people for professional service.
CAUTION–Indicates that failure to follow the instruction may cause body injury or
property damage.
GROUNDING INSTRUCTIONS
This product should be grounded. In the event of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape wire for the electric current. This product is
equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged
into an outlet that is properly installed and grounded.
DANGER –Improper use of the grounding plug can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to
either flat blade terminal. The wire with insulation having an outer surface that is green with or
without yellow stripes is the grounding wire.
This product is factory equipped with a specific electric cord and plug to permit connection to a
proper electric circuit. Make sure that the product is connected to an outlet having the same
configuration as the plug. No adapter should be used with this product. Do not modify the plug
provided — if it will not fit the outlet, have the proper outlet installed by a qualified electrician. If
the product must be reconnected for use on a different type of electric circuit, the reconnection
should be made by qualified service personnel.
SAVE THESE INSTRUCTIONS
.
/37.4~95 F
。

03
Rating power
Technical Specification
Main Unit
Toilet
Rating pressure
Water pressure
range
Electrical wire
Flush volume
Flushing mode Siphonic jet
length is about 1.8m
Minimum water pressure 0.07MPa (20L/min. flow).
Maximum water pressure 0.8MPa (Hydrostatic pressure)
Hole distance
Outlet outside
diameter
Drainage method Down-drain
Heating power
Water
temperature 6 different level adjustment
Water volume 5 different level adjustment
5 different level adjustment
Cleansing mode Rear cleaning/Rear massage,Front cleansing for ladies
Pressure stabilizer,Automatic pressure discharging
Speedy water discharge device, Automatic cleansing
nozzle, Anti-syphon device, Anti-backflow device, Filter
device
Temperature sensor, fail safe device, Bimetallic
thermostat, Temperature fuse, Grounding protection,
Leakage protector
Over 4 M/S
6 different level adjustment
Temperature sensor, Bimetallic thermostat, temperature
fuse
Activated carbon or photocatalyst absorption
250W
1200W
88mm
305mm
1200W-1400W
110V-120V,50/60Hz
Spray cleansing
location
Water pressure
protector
Anti-fouling
device
Safety device
Warm wind speed
Warm wind
temperature
Heating power
Safety device
Deodorization
Method
Deodorization
Cleaning
device
Drying
device
1.6/1.1Gpf(6.0/4.1Lpf)

04
Heated seat
Caring
device
Surface
temperature
Heating power
Open and close
device
Heated burning
protection
Safety device
Night light
assembly
User ID setting
Automatic flushing
Auto lid open/
close(optional)
6 different level adjustment
50W
Quiet soft-closing device,Auto open and close
The seat temperature will automatically lower to level
1 in 10 minutes after using
Seat sensor, Temperature sensor, Bimetallic thermostat,
Temperature fuse
intelligent,often in the off state
To avoid disturbance from remote controls by multi-user
Toilet will automatically flush as user walks away from
bowl
Intelligent lid open/close or by remote controller

List of materials
Installation Manual
Remote controller componentsMain Unit
05
Sealing Flange
Bolts with Retainer
WATER
DRY SEAT
ENERGY
SAVER
PRESSURE POSITION
MASSAGE
FLUSH
NOZZLE
CLEANING
STOP
REAR FRONT DRY
Thank you for choosing our products.Please read the instructions carefully before installation and
keep it available for future maintenance or reference.
ELECTRONIC TOILET SEAT
AUTO AUTO AUTO

Unit: mm
06
Technical drawing
The product shape chart is for reference only, and we reserve the right to
modify the appearance of the product.
595
390
730
475
425

Spray nozzle
Ceramic toilet
Seat
Human body
sensing window
Bumper
Lid
Human body sensing window
Remote sensing window
Half flush button
Full flush button
Deodorization window
Remote sensing window
Main unit disassembly
button
07
Power indicator
Energy saving indicator
Power button
Flush button
Drying button
Front cleaning button
Nozzle baffle
Drying baffle
Rear
cleaning
Front cleaning
Water discharging
Right side
Left side
Parts identification
Rear cleaning button

08
Angle valve
Installation of ceramic toilet
1. Water supply angle valve and bolt
installation
Draw drain outlet centerline on the floor,
Take out the bolt set in the accessory
package and install the bolt on the
retainer.
Install angle valve at proper position on
wall according to dimension of toilet.
Line
Drain outlet
Warm prompt:
The toilet is heavy, and it needs to open the seat
cover to carry it by two people.
2.Installation of sealing flange and toilet
Apply weight evenly.
Do not move after placement.
Water tight seal may break.
Put the sealing flange into the toilet
drain.
Install the toilet on the holder and insert
the bolt into the fixing hole of the toilet.
Toilet drain outlet
Sealing flange
Andere Handbücher für V8300
1
Inhaltsverzeichnis
Andere Woodbridge Badezimmerarmatur Handbücher