Xantrex RC7 - REV 1 Einrichtungshandbuch

Installation and Operator’s Manual
RC7
RC7GS
Xantrex
RV Series
Remote Controls
System Status:
Float Charging

RC7 & RC7GS Remote Controls
Notice of Copyright
Xantrex RC7 and RC7GS Remote Controls Installation and
Operator’s Manual © October 2002 Xantrex International. All rights
reserved.
Xantrex is a registered trademark of Xantrex International.
Disclaimer
UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX
TECHNOLOGY INC. (“XANTREX”)
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFI-
CIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER
INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCU-
MENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS
OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL
OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF
SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION
WILL BE ENTIRELY AT THE USER’S RISK.
Date and Revision
October 2002, Revision 1
Part Number
975-0050-01-01
Contact Information
Web: www.xantrex.com
Email: [email protected]
Phone: 1 800 670 0707 (toll free) 1 604 422 2777 (direct)
Fax: 1 604 420 2145

RC7 & RC7GS Remote Controls
i
RC7 & RC7GS Remote Controls
Table of Contents
Section Description Page
1. Introduction ............................................................... 1
Features ............................................................. 1
ON/OFF Control
Meters
Controls
Status Monitoring
2. Installation ................................................................. 3
3. Operation ................................................................... 5
Front Panel ............................................................. 5
Indicators and Controls
Status LEDs
Inverter LED
Charge LED
Batt. Full LED
Error LED
LCD Display
Push-buttons
On/Off
Setup/Menu Item Push-button
Meter Mode Push-button
Settings Push-button
RC7 and RC7GS Setup Menu .............................. 9
Sense Search
Auto LBCO
Battery Capacity
Battery Type
Charge Rate
Set Shore Power
RC7 Setup
LCD Contrast
External Shunt
Fuelgauge Cutout

RC7 & RC7GS Remote Controls
ii
3. Operation (continued)
RC7GS Setup Menu .............................................. 14
Set Clock (RC7GS Only)
Select Genset
Generator Start
Generator Stop
Begin Gen Quiet and End Gen Quiet
Saving your Setup Choices ................................. 18
RC7 and RC7GS System Status Displays ..........19
AC Source Messages ................................... 19
Waiting for AC
Genset Status:
Pending, Cranking and Genstart
Starter Cooldown and Gen Start
Gen Set Error Messages .............................. 20
Gen Won’t Start
Gen Quiet Fault
Low AC Input V
Inverter Mode Messages ..................................20
Charger Mode Messages ................................. 23
Bulk Charging
Absorption Charging
Float Charging
Equalizing Charging
Inverter/Charger Error Messages .................... 25
Over Temperature
Overload
High Battery Voltage
Low Battery Voltage
DCLD Lockout Error
Charger Fault
Meters Display ....................................................... 28
Average Shunt Amps
Battery Voltage
Inverter/Charger Current
AC Output Voltage
AC Input Amps
Battery Temperature
Transformer Temperature
FET Temperature
Estimated Battery Capacity

RC7 & RC7GS Remote Controls
iii
3. Operation (continued)
System Status Messages ..................................... 31
Battery State of Charge
Time Left to Run
Time Left to Charge
Set Shore Power
Generator Start/Stop
Generator Connection .......................................... 33
Onan Quiet Diesel
Power Tech Wiring Diagrams (2 and 3-wire)
Power Tech 2-wire
Power Tech 3-wire
RC7 and RC7GS Setup Menu .............................. 36
RC7 and RC7GS User Menu ................................ 37
Storage Checklist .................................................. 38
Preparation for Storage
Interior Storage
Exterior Storage
4. Limited Warranty ....................................................... 39

RC7 & RC7GS Remote Controls
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions that should be followed
during the installation and maintenance of this product.
To reduce the risk of electrical shock, and to ensure the safe installation and
operation of this product, the following safety symbols have been placed
throughout this manual to indicate dangerous conditions and important safety
instructions.
WARNING - A dangerous voltage or condition exists in this area.
Use extreme caution when performing these tasks.
CAUTION - This procedure is critical to the safe installation or
operation of the unit. Follow these instructions closely.
NOTE - This statement is important. Follow instructions closely.
•All electrical work must be done in accordance with local, national,
and/or international electrical codes.
•Before installing or using this device, read all instructions and cautionary
markings located in (or on) the manual, the controller, the batteries,
and the PV array.
•Do not expose this unit to rain, snow or liquids of any type. This
product is designed only for indoor mounting.
•To reduce the chance of short-circuits when installing or working with
the inverter, the batteries, or the PV array, use insulated tools.
•Remove all jewelry such as rings, bracelets, necklaces, etc., while
installing this system. This will greatly reduce the chance of accidental
exposure to live circuits.
•The inverter contains more than one live circuit (batteries, PV
array, generator, etc.). Power may be present at more than one source.
•This product contains no user-serviceable parts. Do not attempt to
repair this unit.
SAVE THESE INSTRUCTIONS
iv

RC7 & RC7GS Remote Controls
1
1.0 INTRODUCTION
Features
The RC7 and RC7GS (Generator Start) are control units that allow remote
operation of any RV Series Inverter/Chargers rated from 2000 to 3000 watts.
NOTE: The inverter and remote control must have software version 1.3x.
The RC7 and RC7GS feature:
•Simple menu driven programming for full control of all inverter/charger
functions
•A three-level menu to prevent accidental setting changes
•Meters to display voltage and current
•RJ11 phone jack connection to inverter
•Internal memory to retain inverter/charger menu settings even with a
loss of power
•An Intelligent battery fuel gauge displaying percent of battery charge
and the time left to run
•Error message and informative information displays used to optimize
system performance
•Remote ON/OFF inverter operation
Figure 1
RC7 Front Panel

RC7 & RC7GS Remote Controls
2
All operating controls and indicators for the RC7 and RC7GS are located on
the front panel of the remote control. The inverter, software Rev. 1.3x must be
installed in both the inverter and remote. Refer to the instructions in the RVU-2
Software Upgrade Kit manual if an upgrade is required.
NOTE: The RC7 and RC7GS are identical remote controls; however, the RC7GS
has additional features for controlling a generator. These features are noted in
this manual as available for the “RC7GS only.”
On/Off Control
The inverter portion of the inverter/charger can be switched OFF or ON
using the remote control. The standby charger in the inverter is automatic and
always ready and available for charging whenever AC power is applied.
Meters
The RC7 and RC7GS remotes feature several meters that monitor the
operating conditions of the power center. These meters include: Average Shunt
Amps, Battery Voltage, Inverter/Charger Current, AC Output Voltage, AC Input
Amps, Battery Temperature, Transformer Temperature, FET Temperature, and
Estimated Battery Capacity.
Controls
The RC7 and RC7GS allow the inverter to be switched ON or OFF with the
press of a push-button on the remote. Both devices can be used to configure the
inverter/charger to the specific system and preferences including Battery
Capacity, Battery Type, Charger Rate, Low Battery Cutout, Shorepower Amps,
External Shunt, Fuel gauge Cutout, and Display Contrast. In addition, the
RC7GS starts and stops of the genset automatically or manually, allows the
setting of generator make and model, sets a “quiet time” during which the genset
will not start automatically, and has manual overrides for auto gen start.
Status Monitoring
The RC7 and RC7GS remotes monitor operating conditions including: the
AC supply, inverter operation, charger operation, battery condition, generator
condition (RC7GS only), Time Left to Run, and Time Left to Charge.
1.0 INTRODUCTION

RC7 & RC7GS Remote Controls
3
2.0 INSTALLATION
Installation Procedure:
1. Select an appropriate location to install the remote control.
2. Refer to the drawing (Figure 2) for hole and cutout dimensions or install
the remote in a standard double-gang outlet box.
3. Run the cable between the RC7 remote and the inverter/charger. Do NOT
use standard telephone cable.
4. Place the ON/OFF switch on the inverter to the OFF position and
disconnect the AC power.
Figure 2
Installation Dimensions
CUT OUT THIS AREA
PHONE
JACK
4-1/8"
4"
5-3/16" c-c
4-1/4" c-c
FRONT VIEW
822- 4A- 011

RC7 & RC7GS Remote Controls
4
2.0 INSTALLATION
5. Connect the communications cable into the RJ11 port on the inverter/
charger marked “REMOTE CONTROL.” Connect the other end of the
cable into the jack on the remote (Figure 3).
6. Secure the remote to the wall or outlet box using the appropriate screws
(4 required).
7. Wait for the LCD display to show the message “Waiting for AC.”
8. Place the ON/OFF switch on the inverter to the ON position.
NOTE: The remote will not operate the inverter if the inverter’s ON/OFF switch is
in the OFF position.
9. Reconnect the inverter to the AC source. After a brief delay, the remote
will display a system status message similar to Figure 4.
Figure 3
Remote Control Connectors
“REMOTE CONTROL”
RJ11 Connector RJ11 Connector
Inverter/Charger RC7 RC7GS Remote Control (back view)
ON/OFF Switch
Figure 4
System Status Message (in LCD display)
System Status:
AC Available
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere Xantrex Fernbedienung Handbücher
Beliebte Fernbedienung Handbücher anderer Marken

Panasonic
Panasonic EUR7622KB0 Bedienungsanleitung

Bang & Olufsen
Bang & Olufsen Beo4 Bedienungsanleitung

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Bedienungsanleitung

Multiplex
Multiplex PROFI TX 9 Bedienungsanleitung

One Remote
One Remote RMB4 Bedienungsanleitung

FUTABA
FUTABA 9ZAP - PART2 Bedienungsanleitung