Zenith HydroTap G4 Bedienungsanleitung

801981NZ - CS User Guide - Aug 2015 v2.00 Page 1 of 24
HydroTap G4
User Guide
®
• Tap Operation..................(Pages 2-8)
• LCD Screen & Menu .......(Pages 9-19)
• Maintenance.................... (Pages 19-22)
Date of Installation............./........../...........
Affix Model Number Label
Here
801981NZ
CS Commercial

Page 2 of 24 801981NZ - CS User Guide - Aug 2015 - v2.00
Elite Tap:
The Elite tap uses touch
sensitive controls, to dispense
Chilled and Chilled Sparkling
water.
When operating the tap,
ensure the touch surface is dry
as moisture may interfere with
the sensor touch control.
3. Tap functions
HydroTap Classic:
The HydroTap Classic uses lever
controls, to dispense Chilled and
Chilled Sparkling water.
There are Blue indicator lights, built
into the levers, to show the status of
the chilled water.
There is a filter warning light to
indicate when a filter change is due
NOTE: The safety button on all
Chilled Sparkling models is inactive,
as this function is only necessary
for Boiling water models
Chilled
Lever
Sparkling
Lever
Filter light
Chilled Button
Sparkling button

801981NZ - CS User Guide - Aug 2015 v2.00 Page 3 of 24
3. Tap functions
All-In-One Tap:
The top of the All-In-One tap is operated the same as a Classic HydroTap.
The two levers are used for dispensing Chilled and Chilled Sparkling water.
The Mixer tap lever is operated as a classic ‘Flick Mixer’. The hot side is
marked with a red mark and the cold side with a blue mark, for dispensing
cold to warm water.
Lifting the handle up will decrease the flow rate and lowering the handle will
increase the flow rate. Lift the handle all the way up to turn the tap off.
When the handle is moved towards the blue mark, the temperature is
decreased and when moved towards the red mark, the temperature is
increased. The final temperature will be dependant on the temperature of the
incoming cold water.
For convenience, the spout may be swivelled, left or right through 120°.

801981NZ - CS User Guide - Aug 2015 v2.00 Page 4 of 24
On powerup, wait 30secs. for the unit to calibrate. Tapping the select button
will allow the selection of either the Chilled (BLUE) or Sparkling (White) water
mode.
The Arc/Cube control may be rotated in a forward or reverse direction to
dispense Sparkling or Chilled water.
The rotary control is spring loaded in the anticlockwise direction and when
released, will return to the OFF position. When rotated clockwise the tap
operates in a “Pot fill” mode. Water will flow from between 5 and 15 seconds
(This is user adjustable). To reset, return the handle to the “Off” position and
repeat the step. The lever has to be manually returned to the “Off” position.
When unattended, the control light will automatically default to the Chilled
(BLUE) mode after 30 seconds.
3. Tap functions
Rotary control
Select Button
Safety Lock
HydroTap Arc/Cube:

801981NZ - CS User Guide - Aug 2015 - v2.00 Page 5 of 24
Arc/Cube Tap
3. Tap operation
Elite Tap:
Touching the chilled button
allows the dispensing of
chilled water.
Elite Tap
Indicator
light
To dispense chilled water:
(Classic and AIO Taps)
HydroTap Arc/Cube:
If not showing BLUE, tap the select
button until the indicator light turns
BLUE.
Rotating the control, when the
indicator light is BLUE, allows the
dispensing of chilled water.
To dispense Chilled water:
Depressing the “Chilled” lever allows the
dispensing of Chilled water.
Pulling forward the lever allows the tap
to operate in a “no-touch” mode. Water
will flow from between 5 and 15 seconds
(This is user adjustable). To reset, return
the handle to the “Off” position and repeat
the step. The lever must be manually
returned to the “Off” position.
NOTE:
Chilled water will not be dispensed, if the
safety button is accidentally covered.
Press or Pull the Chilled lever
Chilled button
Select
button

Page 6 of 24 801981NZ - CS User Guide - Aug 2015 - v2.00
Tap operation
HydroTap
Arc/Cube:
If showing BLUE, tap the select
button until the indicator light
turns WHITE.
Rotating the control , when the
indicator light is WHITE, will
allow the dispensing of sparkling
water. When unattended, the
control light will automatically
default to the Chilled (BLUE)
mode after 30 seconds.
Arc/Cube Tap
Indicator
light
Elite Tap:
Touching the Sparkling
button allows the dispensing
of sparkling water.
To dispense Sparkling
water:
Depressing the ‘Sparkling’ lever
allows the dispensing of Sparkling
water. Pulling forward the lever
allows the tap to operate in a in a
“no-touch” mode. Water will flow
from between 5 and 15 seconds
(This is user adjustable). To reset,
return the handles to the “Off”
position and repeat the step. The
lever must be manually returned to
the “Off” position.
To dispense Sparkling water:
(Classic & AIO taps)
Press or Pull the Sparkling lever
Select
button
Elite Tap
Sparkling button

801981NZ - CS User Guide - Aug 2015 - v2.00 Page 7 of 24
Tap lights
Filter light:
(Classic, Elite & AIO taps)
Filter Change Light Off:
This indicates the filter is operating within its
normal specified lifespan.
Filter Change light flashing slowly:
The light will flash slowly when the filter is due
for replacement and the LCD will show “Filter
Change”. Refer to “Replacing the filter” in
section ‘C’ of this document.
Blue Chilled Water Light:
(Classic & AIO taps)
On all the time:
This indicates that the temperature of the
chilled water is within the set temperature
range.
Flashing slowly:
This indicates that the chilled water is not within
the set temperature range. When the chilled
water is at the set temperature, the light will
stop flashing. This could take several minutes.
During heavy usage, the temperature can rise
out of this range.
Filter light
Blue Lights
Filter light
Turn filter light OFF:
(All models)
Refer to “Filter Reset” in section ‘C’
of this document.

Page 8 of 24 801981NZ - CS User Guide - Aug 2015 - v2.00
Filter light:
HydroTap Arc/Cube:
Flashing filter lights:
All three tap lights (Safety; Select and
Indicator light) will flash every
10 seconds, indicating a Filter change
is required.
Safety Light
Indicator
light
Select light
Warning: (All)
Flashing warning light:
When the indicator light flashes fast and
continuous, a system fault has occurred.
Check for details on the faults screen. If
unable to rectify, call a qualified service
agent.
Tap lights

801981NZ - CS User Guide - Aug 2015 - v2.00 Page 9 of 24
Note: When selecting Menu options, the screen will revert to the main
menu, if the screen remains inactive for a period, in excess of 10 seconds.
Zenith HydroTap G4 introduces a ‘TOUCH’ screen for easy setup and
operation adjustment.
Other possible messages in status window:
Status** Information Notes
System Fault Product has one or more system
faults
Refer to section B
Change Filter External/Internal filter needs to be
replaced
Refer to section C
3LCD Screen
**Status window
Set chilled water temperature Filter usage
Date and Time
Sleep mode
icon

Page 10 of 24 801981NZ - CS User Guide - Aug 2015 - v2.00
3LCD Screen Menu
Main Menu Sub Menu Sub Menu Options Section
Language
•
English
A
•
Product Info
•
System
Faults
•
Event Log
•
Product serial
no.
•
Lists
B
Information
Installation
•
Filter Flush
•
Filter Reset
•
Purge CO2
•
Lux sensor
•
Reset options
•
Calibration
options
C
Service Password protected
D
Security
•
Enable
Password
•
Set Password
•
Change
Password
E
Communication
•
Remote
Monitor
•
Remote
Control
•
Wifi / Bluetooth
Options
•
Wifi / Bluetooth
Options
F
Settings
•
Date/Time
•
Temperature
•
Filter
•
Dispense
Times
•
12hr/24hr
Mode
•
Cold Setpoint
•
Filter Life
(Litres)
•
Filter Life
(Months)
•
Cold
Dispensing
G