Device Description
OZ-G2000 is a very powerful oxidant with high reaction potential. This makes it an effective agent for
decomposing destructive substances in the surrounding air. The free radicals bound in the OZ-G2000
molecule are separated from the molecular compound (B) and react with all substances in the
surrounding air, even if these substances are only present in a small concentration. The oxidative
decomposition of pollutants in the air and immovable pollutants (for example, on the floor, wall or
ceiling) will eliminate and eliminate odors by killing viruses, bacteria, molds, and carcinogenic/allergenic
microorganisms.
The OZ-G2000 sucks in the surrounding air and performs a discharge procedure. After that, energy
breaks the diatomic oxygen molecule into two single oxygen atoms in the form of free radicals.
The OZ-G2000 of the Abestorm series uses oxygen in the surrounding air as a molecular compound.
Atomic oxygen recombines with oxygen molecules (A) to form ozone.
Due to their metastable bonds, unoxidized OZ-G2000 molecules will also decompose into oxygen after
a period of time without leaving harmful residues. In indoor spaces and under normal conditions, the
half-life of OZ-G2000 is approximately. 30 to 60 minutes. This means that the OZ-G2000 concentration
in indoor air is naturally reduced by at least half every hour.
After the reactant oxidizes the oxygen atoms, the OZ-G2000 molecules will be converted into oxygen
molecules.
Structure
3
2
5
12
11
9
10
1
4
8
7
6
1.Upper shell 2.LED display 3.Circuit board back cover 4.Wind panel
5.Bottom shell 7.Foot pad 8.Ozone generator
9.Fan 10.Air Inlet 12.Handle

Operation
Note: When "PERIOD" is not set, PERIOD does not light, at this time it is a single scheduled shutdown.
When the button "PERIOD" is set, it switches between 0, 12, and 24. 0 is invalid.12 hours means
that the cycle will run again according to the time set by CLOCK after 12 hours of shutdown, which
is equivalent to the cycle function.
Gears
The default gear for starting is 1 gear, and the fan and OZ-G2000 are 5 gears.
The fan has no thyristor speed regulation, the delay after detecting the zero crossing determines the
size of the gear.
Make sure that the equipment and connecting cables are not damaged.
Connect the power cable and connect the device to the power source. Observe the technical
parameters.
Place the Abestorm OZ-G2000 machine in the center of the room.
Set the timer to the required run time.
Then turn on the device. The display panel will light up. The cleaning cycle will begin immediately.
Once the preset time has passed, the Abestorm OZ-G2000 machine will automatically shut down.
1.
2.
3.
4.
5.
1.
2.
3.
1.
1.
2.
Generally, OZ-G2000 will automatically decompose into oxygen in about an hour. If a person stays
indoors for a long time, it is generally subject to not being able to smell the strong OZ-G2000 smell.
Overall Workflow
When performing odor neutralization and cleaning cycles, follow the steps below.
State Description of Switch
After pressing the "POWER" key to turn on the machine, the default state is the HOLD working
state. That is, it keeps running according to the set gear.
When setting the timing "CLOCK," a file of 30 minutes, cycle between 00:00 and 02:00, that is, set
the running time as the corresponding working time. When CLOCK is valid, HOLD is off, and
CLOCK is on.
The default power-on is the shutdown state. At this time, only the 4 borders shown in the figure
below are lit (the LCD backlight is turned off after the 30s of inactivity).
2

3
Warning
The risk of OZ-G2000 causing harm to the human body!
During use, if you smell OZ-G2000 outside the working area, the machine must stop
working immediately. Ventilate the room thoroughly.
!
The following values are used as a general reference for determining the processing time:
Type of Smell
The treatment time is in min
3
Room size< 30 m
15
20
20
40
40
40-240
360
360
3 3
30 m < Room size< 60 m
30
40
40
60
60
60 - 480
720
720
Disinfectant
Car Interior
From Animals, Cooking and Waste
Burning / Chemical
The Musty Smell After Water Damage
Secondary Effects of a Burning
Smell and Organic Matter
Amine / Amide (urea), Open-chain
Hydrocarbon Compound (e.g.
Butyric Acid)
Amino Acids / Proteins Containing
Nitrogen and Sulfur (vomit)

4
Mistakes and Shortcomings
The equipment has been checked for normal function several times during the production process.
If the fault still occurs, please check the equipment according to the following list.
Warning
Electric shock is life-threatening!
Before performing any operation on the device, please unplug the power plug from
the socket. Do not bypass any electrical safety devices!
In order to ensure the normal operation and trouble-free operation of the equipment, it
must be cleaned and maintained regularly.
!
Problem Cause
Device does not work.
The fuse is blown
The power plug
is damaged.
Solution
Replace the damaged fuse and/or
reopen the fuse. Be careful! The fuse
does not need to be repaired, but it
must be replaced at any time. In most
cases, the fuse is triggered by a serious
technical failure. Please authorized
service personnel to replace each fuse!
Let certified personnel inspect the
equipment.
Loud noise.
Disconnect the power supply of the
device and check whether the power
plug and connecting cable are damaged.
Plug the plug into the socket.
The connection
parameters do not match
the technical
specifications.
Check the connection to the main line.
Connection parameters:
110 V / 60Hz, 1.2A.
Even if the cleaning
process has been
completed, the odor
pollution still persists with
the same intensity.
Send the equipment to a certified
professional workshop for repair.
This device is placed in
an uneven place.
Reactor damage.
Power is not turned on.
Damage to the fan and/or
its bearings.
Place the device on a flat, solid, dry
surface.

5
Maintenance
Electric shock is life-threatening!
Before performing any operation on the device, please unplug the power plug from the
socket. Do not bypass any electrical safety devices!
Inhalation of OZ-G2000 can cause injury!
During use, dust and moisture will accumulate inside or inside the component, which
may affect its function and efficiency.
In a dusty room or after repairing a fire (high humidity level), inspection and
maintenance should be carried out immediately.
After the equipment stops running, please wait for a while to ensure that the OZ-
G2000 concentration is lower than the specified value, and then perform maintenance
and cleaning.
The type and frequency of maintenance tasks basically depend on the operating
environment and the time and type of use.
Please perform regular maintenance and maintenance to ensure the normal operation
and trouble-free operation of the equipment.
!
The basic principles for determining equipment operation and maintenance intervals:
Per hour
1-2 times a week
In a humid room
Often
In an overly dirty environment
Regardless of the operating conditions described, you should perform maintenance if one or
more of the following signs appear:
Severely polluted soft magnetic stickers.
The substances produced during the OZ-G2000 production process gradually disappear.
The noise level increases when the fan is running.
Dirty electrodes (identifiable by hissing sound).
House Cleaning
Clean the case with a soft, damp, lint-free cloth. Make sure that no moisture enters the enclosure.
Prevent electrical components from getting wet. Do not use any harsh cleaning agents, such as cleaning
sprays, solvents, alcohol-based cleaning agents, or abrasives to soak the cloth.
Cleaning
Within the framework of regular maintenance work, it is not only necessary to check the normal
condition of the equipment and its accessories, but also to thoroughly clean the equipment and its
components.
Proceed As Follows:
Remove the screws on the dust cover.
Remove the shell.
Disassemble and clean the fan. Always check whether the fan is working properly. If it is only slightly
contaminated, you can use a vacuum cleaner or a tap to clean it. If the contamination is serious,
clean the reaction OZ-G2000 with a soap solution. After cleaning, insert the fan only after it is
completely dry!
Clean the fan
1.
2.
3.

6
Transportation and Storage
If you store or transport the device incorrectly, the device may be damaged.
Pay attention to information about transportation and storage.
Transportation
Before transporting the equipment, please observe the following regulations:
If the device was in use before, please wait until the timing period is over before transferring the
device.
Turn off the device.
Hold the power plug while unplugging the power cord from the power outlet.
Do not drag the device with the power cord during transportation to prevent the device from moving
and vibrating to avoid damage to the electrode.
After transporting the equipment, please observe the following regulations:
Install the equipment in an upright position after transportation.
Storage
When the device is not in use, please observe the following storage conditions:
Store the Abestorm OZ-G2000 in a dry place to avoid the influence of bad weather, and cover it to
protect it from invasive dust.
When the equipment is not in use, always disconnect the power supply.
Clean Electrode
Ensure that the equipment is protected from splash water.
Make sure that there are no obstructions at the air inlet and outlet.
Make sure to place the device on a dry and vibration-free surface.
If possible, place the device in the center of the room to ensure optimal air circulation.
Do not use the device before the electrodes are completely dry.
Do not install this machine near flammable substances or gases.
Only use the Abestorm OZ-G2000 according to the parameters provided in the "Technical Data" chapter.
The following requirements must be met when installing the Abestorm OZ-G2000:
Use a dry (lint-free) or damp cloth to clean the components. After cleaning, make sure that no fibers
(fluff) remain on the electrode.
The electrode can be cleaned in the built-in state. Before cleaning the electrode, check for cracks. Do
not use damaged parts!

7
Technical Annex
Parameter
Power
Environmental Humidity Requirements
OZ-G2000 Output
Operating Temperature
Sound Pressure Level
Service Life
Size For
Dimensions (L×W×H)
Minimum Distance From Walls and
Other Objects:
Top ( a )
Rear ( b )
Sides ( c )
Front ( d )
Value
110V / 60HZ, 1.2A
< 55%
130 CFM / 220 CMH
15,000 mg/h
< 65 db
25,000 h
1,600 sq. ft
10.2 x 6.9 x 8.7 in
20 in
20 in
20 in
20 in
Airflow

8
Electrical Wiring Diagram
Ozone
Generator
NT
GRN
PCB
Blue
RED
TRANSFORMER Display
PERIOD
FAN
CLOCK
POWER
OZONE
RUN
CAP
Inhaltsverzeichnis
Andere Abestorm Tragbarer Generator Handbücher