ACT LASERPACK Bedienungsanleitung

IOM-101.1 v2
LASERPACK
Installation and Operation Manual

2
ACT Dust Collectors
CAUTION!
Accidents happen, be careful and always follow all local and federal regulations!
Fires and explosions do occur in dust collectors. Many items in a dust form can become very flammable and/or
explosive. It is very important that when installing a dust collector to check with and abide by all local and federal
regulations. Precautions such as spark traps, detectors, and extinguishers are always recommended when sparks or
explosive danger is present. Never throw any burning objects into the duct work or dust collector. There is no way to
guarantee 100% prevention of fires. However, the methods mentioned above will greatly reduce your risk. ACT
Dust Collectors will not be responsible in any way for any loss or damage associated with fires or explosions in your
dust collector.
If your dust collector came with explosion vents or if explosive dusts are present, it is the owner’s/operator’s
responsibility for full compliance with all authorities having jurisdiction. It is recommended that the NFPA codes be
studied and applied, including, but not limited to 68, 69 and 654. Included in the NFPA standards is the issue of
isolating your dust collector. Please contact us or an expert in the area regarding isolation of your dust collector in
the event of an explosion. Unless a Kst test was performed, and we were provided with the results, the size of the
explosion vents may be inaccurate and you may not be in compliance. It is the owner/operators responsibility to
verify the Kst and Pmax values. We recommend that your process be evaluated regularly to make sure that you
remain in compliance and the vent area is sufficient. ACT Dust Collectors will not be responsible for ANY loss
whatsoever resulting from an explosion associated with an ACT dust collector.
Dust collectors are tall and top heavy. Always be careful when handling them. Make sure your equipment is capable
of making the lifts and moves you are trying to make. Be sure the foundation for the dust collector is proper and
secure.
All plumbing and electrical should be performed by certified professionals and meet all codes and regulations.
Never open any doors or access panels while the machine is in operation.
Always shut down the unit prior to service and lock out all disconnects.
Always wear proper safety equipment when working on or around your dust collector and follow all local and federal
codes.
Dust Collector
Model: _____________________________________ Serial Number: _________________________________
Filters: _____________________________________ Ship Date:_____________________________________
Option/Accessories: __________________________________________________________________________
Fan Blower
Manufacturer/Model: __________________________ Serial Number _________________________________
Product Datasheet

3
ACT Cartridge Dust Collector
Table of Contents
Introduction................................................................................................................................................................. 4
Operation Principle..................................................................................................................................................... 5
Shipping and Receiving ............................................................................................................................................. 6
Handling ..................................................................................................................................................................... 6
Assembly
Dust Collector Anchoring .............................................................................................................................. 7
Compressed Air ............................................................................................................................................ 7
Electrical..................................................................................................................................................................... 8
Timer Board Programming......................................................................................................................................... 9
Maintenance
Filter Replacement ...................................................................................................................................... 12
Spark Trap Cleaning ................................................................................................................................... 13
Bag-in Bag-out Collars ................................................................................................................................ 14
Troubleshooting ....................................................................................................................................................... 15
Warranty................................................................................................................................................................... 17

4
ACT Dust Collectors
Introduction
Thank you for your purchase of an ACT dust collector. Our goal is to provide you with a product of best quality,
service, and pricing in the industry.
This manual is to provide general instructions in assisting you with your installation, operation, and maintenance of
your equipment. It is the user’s responsibility to ensure that the equipment is correctly installed and operated. It is
also the user’s responsibility to ensure and provide qualified personnel for the installation, operation, and
maintenance of the equipment and to adhere to all applicable federal and local building and safety codes and
regulations.
Any special instructions and certified drawings accompanying this equipment shall supersede this manual.
Keep this manual along with any special instructions and drawings necessary for assembly, operation, and
maintenance with the equipment.

5
ACT Cartridge Dust Collector
Operation Principle
The ACT cartridge dust collector is a pulse-jet air cleaning device that removes the particulates from dust-laden air
and allows clean air to be exhausted. As dust enters through the dirty air inlet it passes through the cyclonic spark
trap, the heavy particulate is then directed towards the drawers while the remaining fine dust is collected on the
cartridge filter surface, allowing clean air to be exhausted back into the atmosphere.
To remove excess dust buildup on the filters, a timer board is used to sequentially open the diaphragm valves and
release a pulse of compressed air. This venturi-assisted pressure pulse releases the accumulated dusts from the
filters, allowing the particulate to drop down into the drawers.
Dirty Air Inlet
(not shown)
Filtered Dust
Drawers
Dust Filtration Process
&
Pulse-Jet Cleaning Process
ACT Nano-Elite
Premium Cartridges
Clean Air Outlet
(Ambient)
Downward Airflow
Internal
Spark Trap
Integrated
& Silenced Fan
Reverse Pulse-Jet Filter
Cleaning System

6
ACT Dust Collectors
Shipping and Receiving
All products from ACT Dust Collectors are carefully inspected for quality and order completion prior to shipment.
Prior to unloading, inspect all components for any shipping damage and missing parts. Report and file a claim
immediately with the carrier for any damage or missing items. Once filed, contact your ACT Dust Collectors
representative to notify them of your issue(s).
Any repairs to components with minor damage from transit must be approved in writing by the manufacturer.
Handling
Handling should be performed by trained, able, and qualified personnel and be consistent with safe handling
practices outlined by OSHA and local codes.
Review this manual and any additionally supplied certified drawing(s) to familiarize yourself with the lift points of
each of the components.
Verify the integrity and lift capacity of all handling equipment/components.
When handling the housing, it is recommended to utilize spreader bars to prevent any deformation during lifting.
All lifting points are to be used.
Table 1 - Recommended SAE Torque Table
Bolt Size SAE Grade 5 Torque (ft-lb), dry
1/4-20 8.4
5/16-18 17.4
3/8-16 31
7/16-14 49
1/2-13 75
5/8-11 150
3/4-10 267

7
ACT Cartridge Dust Collector
Assembly
Dust Collector Anchoring
Install 3/8 inch diameter anchor bolts with a minimum of 3
inches into the foundation. Ensure foundation complies with all
local regulations and codes
Use recommended SAE torque table for the anchor bolts.
Compressed Air
The supplied compressed air must be clean, dry, and oil-
free. Set the compressed air pressure levels to 80-90
psi. Do NOT exceed 100 psi as damage may occur to
the components.
Prior to installation, purge the compressed air lines of
any dirt or buildup.
1. Install the compressed air pipe line to the air
manifold to either the top or bottom 1” NPT coupling.
Use thread sealant tape or compound on all
connections.
2. A drip tee or ball valve installed on the bottom of the
manifold is recommended to allow for the draining of
any water buildup.
3. It is also recommended to install a shut-off valve,
pressure regulator, safety exhaust valve, and filter
close to the collector.
1” NPT Female Coupling
Plastic Tubing
Air Manifold (Header)
Diaphragm Valve
Solenoid Valves
1” NPT Female Coupling

8
ACT Cartridge Dust Collector
Clean Air Side
Low Pressure Side = –
Dirty Air Side
High Pressure Side = +
Electrical
All wiring but main power lines will be assembled by ACT. In the case of maintenance or repair, refer to below
instructions.
Refer to nameplate in control panel for proper supply voltage.
Refer to page 9 for recommended timer board settings.
———————————————————————————————————————————————————-
All wiring should be done by a certified electrician and in accordance with all local and federal codes.
Refer to the job specific electrical drawing(s) located in the panel and manual binder for detailed instructions.
Fan and timing board/solenoid wiring are to be in separate conduits.
See diagram on page 10 for 5 HP fan wiring
See diagram on page 11 for 10 HP fan wiring
1. Fan
Verify fan rotation by observing from the motor end. Another indication is poor fan performance or a
lack of air movement.
2. Control Panel
The timer board is located inside the control box, mounted on the dust collector.
Once the timer board has been installed, the pressure gauge must be connected to the dust collector
using customer supplied ¼” tubing (see figure below for low and high pressure ports). If the dust
collector is installed outside, the tubing should UV resistant.
IMPORTANT: Prior to operating the dust collector or adjusting the settings, ensure that the
down time clean feature has been properly wired. This feature will allow the dust collector to clean itself
during shut down, which will aid in prolonging the life of the filters.
Control Box

9
ACT Dust Collectors
Timer Board Programming
Familiarize yourself with the timer board manual before programming the timer board.
The table below summarizes the recommended settings. Consult with ACT Dust Collectors for specific applications.
Table – Recommended Timer Board Settings
Feature Settings
Process Current pressure drop
Last Output
The highest output terminal value that has a wire installed in it. Terminal
outputs have a range from 1-22 and are found near the bottom of the timer
board.
Time Off 10
Time On 100
High Limit 1.00” above initial pressure drop
(Contact Manufacturer for Questions)
Low Limit Starting value of 1” below high limit value
High Alarm 10 (Unless alarm is installed - Consult Manufacturing)
Low Alarm 0 (Unless alarm is installed - Consult Manufacturing)
Cycle Delay 0
Down Time Cycles 10
Auto Alarm Reset Unless notified, leave at factory setting of 5.

10
ACT Dust Collectors
WIRING DIAGRAM—5 HP
Inhaltsverzeichnis
Andere ACT Staubabscheider Handbücher
Beliebte Staubabscheider Handbücher anderer Marken

King Industrial
King Industrial KC-4043KWRC Bedienungsanleitung

Jet
Jet 500 Bedienungsanleitung

Oneida Air Systems
Oneida Air Systems Super Dust Gorilla Bedienungsanleitung

Shop fox
Shop fox SHOP FOX W1687 Bedienungsanleitung

Blastrac
Blastrac 655DC Bedienungsanleitung

Elektra Beckum
Elektra Beckum Multi 180A Bedienungsanleitung