ACT ACTENTRY A5 Bedienungsanleitung

Operating & Installation Instructions for
ACTentry A5
18-00064

ACTentry A5 Operating and Installation Manual Rev 1.1
Contents
Installation Notes..........................................................................................................................................................2
Product Specification...................................................................................................................................................2
Ordering Information....................................................................................................................................................2
20 Second Programming……………………………………………………………………………………………………….3
ACTentry A5 Operation................................................................................................................................................4
ACTentry A5 Entry Panel .............................................................................................................................................5
ACTentry A5 Intercom..................................................................................................................................................5
Power Supply................................................................................................................................................................6
Cable..............................................................................................................................................................................6
ACTentry A5 Entry Panel Installation.........................................................................................................................7
ACTentry A5 Intercom Installation.............................................................................................................................. 8
Installation steps ..........................................................................................................................................................9
ACTentry A5 Programming........................................................................................................................................11
PIN Code Management..........................................................................................................................................................11
Changing User PIN Codes:...................................................................................................................................................11
Changing Programming Code:..............................................................................................................................................11
Relay Timers..........................................................................................................................................................................12
Relay Configuration...............................................................................................................................................................12
Backlight Settings ..................................................................................................................................................................13
Incorrect Code Lockout:........................................................................................................................................................13
Restoring Factory Defaults....................................................................................................................................................13
Troubleshooting..........................................................................................................................................................14
ACTentry A5 and Intercom Configuration with DC PSU.........................................................................................15
ACTentry A5 entry panel with intercom and Phone Configuration.......................................................................15
ACTentry A5 and Switch Unit Configuration...........................................................................................................16
ACTentry A5 and Intercom Configuration with AC PSU.........................................................................................17
ACTentry A5 Dimensioned Diagram.........................................................................................................................17
User List.......................................................................................................................................................................18
1

ACTentry A5 Operating and Installation Manual Rev 1.1
Installation Notes
•Remember to Factory Default the ACTentryA5 before programming
•Remember to place the supplied varistor across the terminals of the door strike coil to protect
the relay contacts
•Never use the on-board relays to switch AC mains voltage. An external relay, electrically
isolated from the ACTentryA5 should be used for this purpose
•Remember to change the programming code.
Product Specification
Number of Users 10
Entry Panel Supply Voltage 15 - 24V DC or AC
Intercom Supply Voltage 15 - 24V DC only
A5 Entry Panel Current Consumption 300mA (maximum)
Intercom Current Consumption 150mA (maximum)
Switch Unit Current Consumption 80mA (maximum)
Operating Temperature -10 to +60 degrees C
Door Open Time 2 - 255 seconds
Max distance from Intercom and Entry Panel 200m maximum (Belden, CAT5 or
external rated CAT 5 for external use)
Relay Contact Rating 5A / 250Vac
Water Resistance High IP56 (Entry Panel),
IP54 (Intercom)
Construction Rugged Polycarbonate housing
Ordering Information
Product Code Description
ACTENTRYA5E-PAN entry panel (external)
ACTENTRYA5ICOM intercom (internal)
ACTENTRYA5SWITCH switch unit for multiple entry panels
ACTENTRYA5ICOM-K intercom kit (entry panel, intercom & PSU)
ACTENTRYA5PSU DC power supply unit
2

ACTentry A5 Operating and Installation Manual Rev 1.1
20 Second Programming Guide
1.Factory Default:
Step Keypad Entry Operation
1 9999 Enter Programming Mode
2 Change Programming code
3 Exit programming
The ACTentry A5 may be returned to its
factory default settings at any time by
entering the programming mode and
pressing the tick ( ) key three times.
Note: The default Programming code is 9999 and the default code for User 1 is 1234. ACT
recommends these codes are changed immediately after defaulting.
Step Keypad Entry Operation
1 9999 Enter Programming Mode
2 0 Change PIN codes
3 Change Programming code
4 5214 Enter new 4-digit Programming code
5 Exit programming
2.Change Programming Code:
Example: Make 5214 the new
programming code
9999 0 5214
Step Keypad Entry Operation
1 5214 Enter Programming Mode
2 0 Change PIN codes
3 1 Enter User Number 0-9
4 7529 4-digit code
5 Exit programming
3.Change User Code:
Example: Assign code 7529 to User 1
5214 0 1 7529
4.Lost or forgotten programming code (Hardware factory Default)
If the Programming Code has been forgotten the unit maybe hardware factory defaulted. This will
set the programming code to 9999 and the code for user 1 to 1234.
1. Remove the power from the ACTentry A5 Entry Panel.
2. Remove link LK1.
3. Apply power to unit (with LK1 removed).
4. Replace link LK1.
5. Programming Code is now set to 9999. Note: the unit has been factory defaulted.
Note: The ACTentry A5 will not operate correctly without LK1 in place. CALL led flashes amber rapidly.
3

ACTentry A5 Operating and Installation Manual Rev 1.1
ACTentry A5 Operation
The ACTentry A5 Entry Panel is contained in rugged polycarbonate housing, with programmable
backlighting, dual relays and potted electronics, allowing for indoor and outdoor installation. The
unit will operate with the ACTentry Intercom and ACTentry Phone. Up to 4 intercoms or phones
may be connected to the Entry Panel at a maximum distance of 200m.
The ACTentry A5 Switch Unit is available if a second Entry Panel is required.
Unit C1, South City Business Centre,
Tallaght, Dublin 24, Ireland.
Tel: +353 (0)1 466 2570 UK Lo-call: 0845 300 5204
Web: www.accesscontrol.ie or www.act.eu E-mail: sales@ accesscontrol.ie
Copyright ©2009 Access Control Technology Ltd.
4

ACTentry A5 Operating and Installation Manual Rev 1.1
ACTentry A5 Entry Panel
The Entry Panel is securely mounted on the wall at the entrance
to the premises. It consists of a speaker grille (label 2), CALL
button for visitors (label 3) and a keypad (label 4). The keypad is
used for PIN code access or to configure the unit.
Visitors press the CALL button to speak to the householder.
Regular users enter their PIN code to gain access (up to 10 User
Codes).
The keypad and call button are backlit for use in low ambient
light. The backlight can be switched off if desired.
The Entry Panel is rated for IP56. A security screw is concealed
under the cap (label 1).
The volume of the speaker may be adjusted if the unit is in a noisy environment (see page 7).
6 wires minimum are required to connect to the ACTentry Intercom or the ACTentry Phone.
Additional wires are required to connect the onboard relays to the gates or doors.
ACTentry A5 Intercom
The Intercom is mounted indoors and has an integrated speaker (label
2), TALK button (label 3), release buttons for Relay 1 and Relay 2 and
a volume control button (label 4).
Adjust Ring Volume
The Intercom rings when a visitor presses the CALL Button on the
Entry Panel. The volume of the ringing may be adjusted by pressing
the - and + keys.
Adjust Speech Volume
To answer the call, the householder presses the TALK button and begins speaking. The speech
volume may be adjusted using the - and + keys.
To end the call, the householder should press either 1 or 2 to activate the relays, or press the
TALK button.
Activate Relay Indefinitely (Toggle)
Each relay may be switched on indefinitely by holding down the corresponding key on the
intercom for five seconds. This allows the door or gate to be opened indefinitely and the
corresponding button will flash while the relay is active. Press the button again to restore the
relays to the normal state.
5

ACTentry A5 Operating and Installation Manual Rev 1.1
Power Supply
The ACTentry A5 kit comes with a 15V 800mA DC power
supply. This is enough power to supply 1 Entry Panel, and 3
Intercoms/Phones.
The connections to the 240Vac mains supply must be carried
out by a qualified electrician and made in accordance with
accepted safety practices.
Cable
Cable Requirements:
For optimum speech clarity, it is strongly recommended that the ACTentry A5 system is installed
using CAT5 cable or equivalent. For external use it is recommended to use external rated CAT 5
or equivalent.
The maximum distance between the Entry Panel and Intercom is 200m.
One CAT5 core is suitable for all signal wires (CALL, R, T, DOOR 1 and DOOR2).
Power cables (+VIN and 0V) require doubling up on runs of 100m and 200m.
Please use the table below as a guide.
Connection 50m 100m 200m
+VIN 1 2 4
0V 1 2 4
CALL / I 1 1 1
R 1 1 1
T 1 1 1
DOOR1 / Z 1 1 1
Example: For 50m distance from Entry Panel to Intercom, 6 cores are required. For 100m
distance, 8 cores are required, 2 for +VIN, 2 for 0V. Signals require one core each.
6

ACTentry A5 Operating and Installation Manual Rev 1.1
ACTentry A5 Entry Panel Installation
The ACTentry Entry Panel is made from 2 separate parts: a front unit and a base unit. The front
unit contains the speaker and keypad. The base unit contains the electronics, microphone and
connector blocks. The two units are interconnected via 2 flying leads, one for speaker (label 4)
and one for the keypad (label 6). Handle these connections with care when connecting or
disconnecting!
1.Connector Blocks
2.Volume potentiometer
3.Volt-Free Tamper
4.Speaker connector
5.Microphone
6.Keypad connector
7.Default Link LK1
Connector Description
+VIN +DC Voltage of 15V to 24V or 24Vac
0V 0 Volts
NO Normally Open Relay Contact
C Common Relay Contact
NC Normally Closed Relay Contact
TAMP Normally Closed Dry Contact (Volt Free). Normally closed in tamper conditions.
CALL / I Normally low output, + 15V signal to Intercom to ring when CALL button pressed
R Audio signal intput from Intercom
O 0 Volts
T Audio signal output to Intercom
DOOR1 / Z Normally 5V input, 0V signal from Intercom and Phone to open Door 1
DOOR 2 Normally 5V input, 0V signal from Intercom to open Door 2
7

ACTentry A5 Operating and Installation Manual Rev 1.1
ACTentry A5 Intercom Installation
The ACTentry Intercom is made from 2 separate parts: a front unit and a base unit. The front unit
contains the speaker and keypad. The base unit contains the electronics, microphone and
connector blocks. The two units are interconnected via 2 flying leads, one for speaker (label 4)
and one for the keypad (label 6). Handle these connections with care when connecting or
disconnecting!
1.Connector Blocks
2.Speaker connector
3.Microphone
4.Keypad connector
Connector Description
+VIN +DC Voltage of 15V to 24V – Do not use AC.
0V 0 Volts
CALL / I Normally low input, + 15V signal to ring intercom
R Audio signal output to Entry Panel
O 0 Volts
T Audio signal input from Entry Panel
DOOR1 / Z Normally 5V output, 0V signal when Button 1 is pressed
DOOR 2 Normally 5V output, 0V signal when Button 2 pressed
8

ACTentry A5 Operating and Installation Manual Rev 1.1
Installation steps
1.Fix the base units of the Entry Panel and Intercom to the wall and connect as shown below.
2. Attach the keypad and speaker cables to their connectors on
the base unit. Handle these connections with care! Both
connectors are polarised and can only go in ONE way.
Forcing the connectors may permanently damage the unit.
3.Attach front unit to the bottom of the base unit
4.Close over from the top.
5.Repeat steps 2 to 4 for Intercom units.
6.Power up the system.
9
Andere Handbücher für ACTENTRY A5
1
Inhaltsverzeichnis
Andere ACT IP-Zugriffskontrollsysteme Handbücher

ACT
ACT ACTPRO 1000 Kurzanleitung

ACT
ACT ACTPRO 4000 Bedienungsanleitung

ACT
ACT ACTPRO 1010 Bedienungsanleitung

ACT
ACT ACTPRO 4000 Bedienungsanleitung

ACT
ACT ACTPRO 3000 ACCESS CONTROL UNITS Bedienungsanleitung

ACT
ACT ACTPRO 2000 Bedienungsanleitung

ACT
ACT ACTsmart2 Series Bedienungsanleitung

ACT
ACT ACTENTRY A5 Bedienungsanleitung

ACT
ACT 5e prox Produkthandbuch

ACT
ACT ACT1000 - ACCESS CONTROL UNIT - INSTALLERS Produkthandbuch