AerAtron AE+2 Series Bedienungsanleitung

INSTRUCTION MANUAL
AE+2 & AE+3

ATTENTION ELECTRICIANS
Available in: 43”/1092mm 50”/1270mm 60”/1524mm
LED Light Kit & Ceiling Extension Kit are oponal for all Aeratron™ models
AE+2 & AE+3 CEILING FAN
An isolaon switch per fan is highly recommended.
WARNING: If unusual oscillang movement is observed, immediately
stop using the ceiling fan and contact the naonal distributer/retailer.
USER MANUAL & INSTALLATION GUIDE
For Metal Hanger Bracket with Safety Cord
Check Fan Suspension system regularly, at least once every two years.

Important information - Please read before attempting installation
1
!
This fan must be installed by a licensed and qualified
electrician according to local authority regulaons.
1. Please read these instrucons carefully, be mindful of all warnings and safety informaon shown
throughout this manual. Should you have any quesons please call your local agent.
2. Please review the accompanying assembly diagrams before aempng installaon.
3. This fan MUST be installed by a licensed & qualified electrician according to local authority
regulaons and in accordance with current wiring rules of the country/state.
4. A copy of the purchasing receipt and proof of installaon by a licensed and qualified electrician
according to local authority regulaons is required for all warranty claims.
5. Where special access equipment is required to service the fan in accordance with local authority
regulaons all associated costs are the responsibility of the owner.
6. Should a warranty claim be required, we reserve the right to charge a service fee for all call outs
where the fan is found not to be defecve and / or where access is not provided.
7. To enable future programming, maintenance, cleaning and troubleshoong an isolaon switch per
fan is highly recommended. Without an isolaon switch per fan, an electrician maybe required to
assist with programming, maintenance, cleaning and troubleshoong. All associated costs are the
responsibility of the owner.
8. A Maximum of 8 fans on each RCD / circuit is recommended. The fans are a Class 5 Device with
leakage to Earth.
9. Your warranty will be void if a solid state dimmer or any other brand of wall controller is used.
10. The means for mains power disconnecon must be incorporated in the fixed wiring in accordance
with naonal wiring rules.
11. To avoid possible electric shock during installaon, be sure electricity is turned off at the main power
box before commencing work. Disconnect power by removing fuse or turning off circuit breaker
before installing the fan. Ensure all spliced connecons are adequately insulated.
12. Warning! Do not allow the rotang fan blades to come into contact with any object, this can cause
serious injury or death.
13. Damage caused by incorrect installaon, Force-majeure, lightning, electrical surges & spikes,
exposure to water, pests or moisture is not covered under warranty.
14. This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilies, or lack of experience and knowledge, unless they have been given supervision
or instrucon concerning use of the appliance by a person responsible for their safety.
15. Suspension System
· the replacement of parts of the safety suspension system device shall be performed by the
manufacturer, its service agent, or suitably qualified persons.
· fixing means for aachment to the ceiling such as hooks, or other devices shall be fixed with a
sufficient strength to withstand 4 mes the weight of the ceiling fan.
· the mounng of the suspension system shall be performed by the manufacturer, its service agent,
or suitably qualified persons
· the model or type reference of a luminaire that may be installed in a fan must be constructed for
this purpose
Australia, New Zealand: In accordance with AS/NZS60355-1 & ASNZS60355-2-80: “This appliance is
not intended for use by persons (including children) with reduced physical, sensory or mental
capabilies, or lack of experience and knowledge, unless they have been given supervision or
instrucon concerning use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.”

Contents
2
IMPORTANT
assistance before leaving the site.
Important Informaon ................................................................................................................ 1
Contents ...................................................................................................................................... 2
Unpacking your fan ..................................................................................................................... 3
Installing your Fan ....................................................................................................................... 4
STEP1 Mounng the Hanger Bracket to Ceiling....................................................................... 4
STEP 2 Connecng Mains Power to Terminal Block.................................................................4
STEP 3 Inserng Fan Motor into Hanger Bracket..................................................................... 5
STEP 4 Installing Receiver into Hanger Bracket ....................................................................... 5
STEP 5 Connecng Receiver..................................................................................................... 6
STEP 6 Pairing the Remote Control .........................................................................................7
STEP 7 Aaching the Fan Motor Housing ................................................................................ 8
STEP 8 Assembling the Fan Blades........................................................................................ 8,9
STEP 9 Aaching the Fan Blades ............................................................................................. 9
Opon A - LED Light Kit .............................................................................................................10
Opon B - Ceiling Extension Kit................................................................................................. 10
Opon C - Raked Ceiling Kit....................................................................................................... 11
Technical Specificaon .............................................................................................................. 12
Care and Cleaning ..................................................................................................................... 13
Troubleshoong ........................................................................................................................ 13
If the fan is noisy .................................................................................................................... 13
If the fan rotates but does not create much airflow.............................................................. 13
General Informaon.................................................................................................................. 14
Normal Wear and Tear .......................................................................................................... 14
Warranty details........................................................................................................................ 15

3
Unpacking your fan
Unpack your fan and examine all parts, you should have the following:
CONTROL RECEIVER
MOTOR HOUSING
AE+3 HUB UPPER
AE+3 HUB LOWER
AE+2 HUB UPPER
AE+2 HUB LOWER
FAN BLADE: AE+2 x 2
AE+3 x 3
CEILING SPACER x 2
OR
OR
METAL HANGER BRACKET
MOTOR ASSEMBLY
SAFETY CORD
TIMBER SCREWS X 5
PIVOT LOCK X1
HUB SCREWS X 10
EXPANSION BOLT X 4
HOOK BOLT X 1
REMOTE CONTROL
AAA BATTERIES x2
NOTE: Wall control / automaon control & wifi module components are not included;
please contact your local fan supplier for more informaon.

STEP 1 Mounting Metal Hanger Bracket to Ceiling
supply at the main power box. Disconnect power
by removing fuse or turning off circuit breaker.
!
STEP 2 Connecting Mains Power to Terminal Block
4
Install hanger bracket to ceiling joist or concrete ceiling using a minimum of (4) bolts/ screws as provided. Ensure
ceiling joists are sound and of adequate size and strength to support a 32Kg (70lbs) load. If a mber frame is to be
added it must be securely nailed or screwed between two beams. Mount the hook bolt / mber screws for the
safety cable within the motor housing opening, approx Ø165mm from the centre of the hanger bracket.
WARNING: MOUNT ONLY TO AN OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT.
This fan is to be installed so that the blades are more than 2.3m above the floor
OPTION A:
Ceiling Joist
OPTION B:
Concrete Ceiling
Ø165mm
Hook bolt or
mber screw
Expansion bolt or
mber screw
4 mber screws 4 expansion bolts
N
L
CONNECT WITH RECEIVER
3PIN
NEUTRAL
LIVE
L
LIVE
LIVE
GROUND
GREEN
BROWN L
BLUE N
FROM HOUSE
(Mains Power)

Inserting an otor into Hanger Bracket and
=
STEP 4 Installing Receiver into Hanger Bracket
5
STEP 3
Wooden Ceiling (use Timber Screws)
Concrete Ceiling (use Expansion Bolts)
Secure Safety Cord Loop
with Timber Screw
Secure Safety Cord
Loop with Hook Bolt
Locate Suspension Ball in Hanger Bracket and secure the (loop) of the Safety cord to the
hook expansion bolt or secure the Safety cord loop to the Ceiling with the Timber Screw.
Ensure the safety cord is not stretched otherwise it will hinder the receiver sliding
through the hanger bracket.
Secure Safety Cord
Slide Remote Control Receiver
into Hanger Bracket from the
opposite side of the Terminal block
in the orientaon as shown below.
Oponal
Wifi module
Antenna

6
Connecting the Receiver
STEP 5
X0
Learn Switch
Switch to “O” to pair receiver
with the Remote control and
Switch to “X” to lock the pairing
code with the Remote control
2PIN LED driver connection
(optional for LED light)
3PIN
3PIN
Mains Power
Aerial
4PIN Comms
Connector
(Optional USE ONLY
IF INSTRUCTED)
1.
2.
Connect the 3PIN connector (Mains Power)
between Hanger Bracket and Reciever.
Connect the3PIN
& Earth cable connector
between DC Motor and Receiver.
3PIN
Receiver to
Hanger bracket
3PIN
Receiver
to Motor
Earth Cable

The remote control is pre-programmed
No pairing with the receiver required
STEP 6 Pairing the Remote Control
Controlling the Fan
1. Fan ON/OFF
2. Fan Speed UP/DOWN
2a. Fan Speed indicator 1-6
3. Forward / Reverse
3a. Use Forward mode (counterclockwise) for cooling
3b. Use Reverse mode (clockwise)
to circulate warm air
4. Light ON/OFF
4a. To DIM, press and HOLD light buon
to cycle from bright to dark.
(LIGHT SWITCH at DIMMING posion)
Pairing Mulple Fans per Remote Control
One remote control can control up to 8 fans (within a 7m (23”) radius).On ALL receivers verify that
the “Learn” switch is in the “O” posion. Switch on the mains power to acvate ALL receivers at the
same me, indicated by one ‘beep’. Within 60 seconds, press and hold the ON/OFF buon on the
remote control (min. 3 seconds) unl fan receiver issues three ‘beeps’.
!
1
4
3b
2
2a
3
3a
4a
LIGHT SWITCH
O LIGHT DIMMING
| LIGHT ON/OFF
Pairing a Single Fan per remote control: LEARN MODE
NOTE: Blades must be aached prior to tesng the fan
1. On Receiver: Verify that the “Learn” switch is in the “O” posion
2. Open baery cover & insert baeries.
3. Switch on the main power to acvate the receiver, indicated
by one beep. (Energise one fan reciever at a me).
4. Within 60 seconds aer the power is turned on (one beep),
press and hold the ON/OFF buon on the Remote Control
(min. 3 secs.) unl Fan Receiver issues three ‘beeps’ which
indicates successful pairing.
5. On Receiver: switch the “Learn” switch to “X” (this will
lock the pairing code with the remote)
6. Finish STEP 7, 8 & 9 and press ON/SPEED buon to test
fan funcons.
7. To re-pair, repeat steps 3 to 5
NOTE: Power must be off for 10 seconds min. before repairing.
The Remote Control and Fan Receiver will memorise the pairing
code for future use even if mains power is switched off.
LIGHT SWITCH: Select ON/OFF or DIMMING for the light funcon.
(Light will maintain last seng if turned off)
7

8
STEP 7 Attaching the Fan Motor Housing
Align the 3 tabs with the 3 holes on the
Housing and move upwards. Push tabs
inwards slightly before sliding upwards
unl you hear a click as the tabs lock.
STEP 8 Assembling the Fan Blades
A B
Place the Hub Upper onto a clean working area.
Line-up the two mounng holes in the Fan Blade
with the 2 holes in the Hub Upper. To ensure ght and secure blade assembly a
power tool on low torque seng (4-6) can
be used.
Fix the 3 Fan Blades ght and firm using 2 Hub
screws for each Blade.
Connues next page
CLICK!
Constantly handle fan with care at all mes to
avoid damaging the fan/surface
!
Dieses Handbuch passt für folgende Modelle
7
Inhaltsverzeichnis
Andere AerAtron Lüfter Handbücher

AerAtron
AerAtron AE2 Bedienungsanleitung

AerAtron
AerAtron E502 Bedienungsanleitung

AerAtron
AerAtron FR3 Series Montage- und Bedienungsanleitung

AerAtron
AerAtron FR3 Series Montage- und Bedienungsanleitung

AerAtron
AerAtron Ceiling Extension Bedienungsanleitung

AerAtron
AerAtron AE2+ Series Montage- und Bedienungsanleitung