AJAX Systems DoorProtect Bedienungsanleitung

DoorProtect User Manual
Updated November 18, 2021
DoorProtect is a wireless door and window opening detector designed for indoor
use. It can operate up to 7 years from a pre-installed battery and capable to detect
more than 2 millions openings. DoorProtect has a socket for connecting an
external detector.
The functional element of DoorProtect is a sealed contact reed relay. It consists of
ferromagnetic contacts placed in a bulb that form a continuous circuit under the effect of a
constant magnet.
DoorProtect operates within the Ajax security system, connecting via the protected
radio protocol. Communication range is up to 1,200 m in the line of sight.
Using the or integration modules, DoorProtect can be
used as part of third party security systems.
Jeweller
uartBridge ocBridge Plus

The detector is set up via for iOS, Android, macOS and Windows. The
app noties user of all events through push notications, SMS and calls (if
activated).
The Ajax security system is self-sustaining, but the user can connect it to the
central monitoring station of a private security company.
Functional Elements
Ajax apps
Buy opening detector DoorProtect
1. DoorProtect
2. Big magnet (should be placed to the right of the detector)
3. Small magnet (should be placed to the right of the detector)
4. LED indicator
5. SmartBracket attachment panel (perforated part is required for actuating the
tamper in case of any attempt to dismantle the detector. Don’t break it out!)
6. External detector connection socket
7. QR code
8. Device switch

Operating Principle
DoorProtect consists of two parts: the detector with a sealed contact reed relay,
and the constant magnet. Attach the detector to the door frame, while the magnet
can be attached to the moving wing or sliding part of the door. If the sealed contact
reed relay is within the coverage area of the magnetic eld, it closes the circuit,
which means that the detector is closed. The opening of the door pushes out the
magnet from the sealed contact reed relay and opening the circuit. In such a way,
the detector recognizes the opening.
Attach the magnet to the RIGHT of the detector.
A small magnet works at a distance of 1 cm, and the big one — up to 2 cm.
After actuation, DoorProtect immediately transmits the alarm signal to the hub,
activating the sirens and notifying the user and security company.
Pairing the Detector
Before starting pairing:
9. Tamper button
1. Following the hub instruction recommendations, install the on your
smartphone. Create an account, add the hub to the app, and create at least one
room.
Ajax app
2. Switch on the hub and check the internet connection (via Ethernet cable and/or
GSM network).
3. Make sure that the hub is disarmed and does not update by checking its status
in the app.

Only users with administrator rights can add the device to the hub.
How to pair the detector with the hub:
1. Select theAdd Device option in the Ajax app.
2. Name the device, scan/write manually the QR Code (located on the body and
packaging), and select the location room.
3. SelectAdd— the countdown will begin.
4. Switch on the device.

For detection and pairing to occur, the detector should be located within the
coverage area of the wireless network of the hub (at the same facility).
The request for connection to the hub is transmitted for a short period of time at
the moment of switching on the device.
If pairing with the hub failed, switch off the detector for 5 seconds and retry it.
If the detector has paired with the hub, it will appear in the list of devices in the Ajax
app. The update of the detectors statuses in the list depends on the detector ping
interval set in the hub settings. The default value is 36 seconds.
Connecting to Third-Party Systems
To connect the detector to a third-party security central unit using the or
integration modules, follow the recommendations in the user
manual of the respective device.
States
The states screen contains information about the device and its current
parameters. Find the DoorProtect states in the Ajax app:
uartBridge
ocBridge Plus

Parameter Value
Temperature
Device temperature. It is measured on the
processor and changes gradually. Displayed in
1°C increment.
Acceptable error between the value in the app and
temperature at the installation site: 2–4°C
Jeweller Signal Strength
Signal strength between the hub/range extender
and the opening detector.
We recommend installing the detector in places
where the signal strength is 2–3 bars
Connection
Connection status between the hub/range
extender and the detector:
ReX range extender name
ReX range extender connection status.
Displayed when the detector works via
Battery Charge
Battery level of the device. Displayed as a
percentage
Lid The tamper state, which reacts to detachment or
damaging of the detector body
Delay When Entering, sec Entry delay (alarm activation delay) is the time
1. Go to the Devices tab.
2. Select DoorProtect from the list.
Online — the detector is connected with the
hub/range extender
Oine — the detector has lost connection
with the hub/range extender
ReX
radio signal range extender
How battery charge is displayed in
Ajax apps

you have to disarm the security system after
entering the room
Delay When Leaving, sec
Delay time when exiting. Delay when exiting
(alarm activation delay) is the time you have to
exit the room after arming the security system
Night Mode Delay When Entering, sec
The time of Delay When Entering in the Night
mode. Delay when entering (alarm activation
delay) is the time you have to disarm the security
system after entering the premises.
Night Mode Delay When Leaving, sec
The time of Delay When Leaving in the Night
mode. Delay when leaving (alarm activation
delay) is the time you have to exit the premises
after the security system is armed.
Primary Detector The primary detector status
External Contact The status of the external detector connected to
DoorProtect
Always Active
If the option is active, the detector is always in
armed mode and noties about alarms
Chime
When enabled, a siren noties about opening
detectors triggering in the Disarmed system
mode
Temporary Deactivation Shows the status of the device temporary
deactivation function:
What is delay when entering
What is delay when leaving
What is delay when entering
What is delay when leaving
Learn more
What is chime and how it works

Firmware The detector rmware version
Device ID The device identier
Device No. Number of the device loop (zone)
Settings
To change the detector settings in the Ajax app:
No — the device operates normally and
transmits all events.
Lid only — the hub administrator has disabled
notications about triggering on the device
body.
Entirely — the device is completely excluded
from the system operation by the hub
administrator. The device does not follow
system commands and does not report
alarms or other events.
By number of alarms — the device is
automatically disabled by the system when
the number of alarms is exceeded (specied
in the settings for Devices Auto Deactivation).
The feature is congured in the Ajax PRO app.
By timer — the device is automatically
disabled by the system when the recovery
timer expires (specied in the settings for
Devices Auto Deactivation). The feature is
congured in the Ajax PRO app.
1. Select the hub if you have several of them or if you are using the PRO app.
2. Go to the Devices tab.
3. Select DoorProtect from the list.
4. Go to Settings by clicking on the .
5. Set the required parameters.
6. Click Back to save the new settings.

Setting Value
First eld
Detector name that can be changed. The name is
displayed in the text of SMS and notications in
the event feed.
The name can contain up to 12 Cyrillic characters
or up to 24 Latin characters
Room
Selecting the virtual room to which DoorProtect is
assigned. The name of the room is displayed in
the text of SMS and notications in the event feed
Delay When Entering, sec
Selecting delay time when entering. Delay when
entering (alarm activation delay) is the time you
have to disarm the security system after entering
the room
Delay When Leaving, sec
Selecting the delay time when exiting. Delay when
exiting (alarm activation delay) is the time you
have to exit the room after arming the security
system
Arm in Night Mode If active, the detector will switch to the armed
mode when using the night mode
Night Mode Delay When Entering, sec
The time of Delay When Entering in the Night
mode. Delay when entering (alarm activation
delay) is the time you have to disarm the security
system after entering the premises.
Night Mode Delay When Leaving, sec
The time of Delay When Leaving in the Night
mode. Delay when leaving (alarm activation
delay) is the time you have to exit the premises
after the security system is armed.
What is delay when entering
What is delay when leaving
What is delay when entering
What is delay when leaving

Alarm LED indication Allows you to disable the ashing of the LED
indicator during an alarm. Available for devices
with rmware version 5.55.0.0 or higher
Primary Detector If active, DoorProtect primarily reacts to
opening/closing
External contact If active, DoorProtect registers external detector
alarms
Always Active
If the option is active, the detector is always in
armed mode and noties about alarms
Alert with a siren if opening detected If active, added to the systemare
activated when the opening detected
Activate the siren if an external contact opened If active, added to the systemare
activated during an external detector alarm
Chime settings
Opens the settings of Chime.
Jeweller Signal Strength Test
Switches the detector to the Jeweller signal
strength test mode. The test allows you to check
the signal strength between the hub and
DoorProtect and determine the optimal
installation site
Detection Zone Test
Switches the detector to the detection area test
Signal Attenuation Test Switches the detector to the signal fade test
mode (available in detectors with rmware
How to nd the rmware version or
the ID of the detector or device?
Learn more
sirens
sirens
How to set Chime
What is Chime
What is Jeweller Signal Strength Test
What is Detection Zone Test
Andere Handbücher für DoorProtect
1
Inhaltsverzeichnis
Andere AJAX Systems Sicherheitssensor Handbücher

AJAX Systems
AJAX Systems MotionProtect Outdoor Bedienungsanleitung

AJAX Systems
AJAX Systems MotionCam Bedienungsanleitung

AJAX Systems
AJAX Systems DoorProtect Bedienungsanleitung

AJAX Systems
AJAX Systems DoorProtect Plus Bedienungsanleitung

AJAX Systems
AJAX Systems StreetSiren Bedienungsanleitung

AJAX Systems
AJAX Systems Hub Plus Bedienungsanleitung

AJAX Systems
AJAX Systems MotionCam Bedienungsanleitung

AJAX Systems
AJAX Systems GlassProtect Bedienungsanleitung