ANEMOI AIRPRO M Bedienungsanleitung

AIRPRO [M]
Installation Manual
Issued January 2020
ANIM08AI Rev. A

AIRPRO [M]
2
UPDATES
DATE
UPDATE
DESCRIPTION
26 / 02 / 2020 A First Edition
Technical documents are regularly updated. Anemoi reserves the right to modify the contents of this manual, in full or in part,
without warning.

AIRPRO [M]
3
TABLE OF CONTENTS
SAFETY .................................................................................................................................................................. 4
1 INTRODUCTION ............................................................................................................................................ 5
2 TECHNICAL CHARACTERISTICS ............................................................................................................... 6
3 DIMENSIONS ................................................................................................................................................. 7
4 DELIVERY ..................................................................................................................................................... 8
4.1 Package Dimensions & Weights ............................................................................................................ 8
4.2 Packing List ........................................................................................................................................... 8
4.3 Fan diagram ........................................................................................................................................ 10
5 MECHANICAL INSTALLATION .................................................................................................................. 11
5.1 Clearances .......................................................................................................................................... 12
5.2 Installation Tools .................................................................................................................................. 13
5.3 I-Beam Conditions ............................................................................................................................... 13
5.4 Pre-installation Checklist ..................................................................................................................... 14
5.5 Ceiling Mount Bracket.......................................................................................................................... 15
5.6 Extension Rod Assembly ..................................................................................................................... 16
5.7 Motor Assembly ................................................................................................................................... 17
5.8 Safety Cable Installation ...................................................................................................................... 18
5.9 Wiring Location .................................................................................................................................... 19
5.10 Extension Tube Shield Installation ....................................................................................................... 20
5.11 Guy Wires Fixation (optional) .............................................................................................................. 21
5.12 Blades Assembly ................................................................................................................................. 23
6 ELECTRICAL INSTALLATION ................................................................................................................... 24
6.1 Remote Control Fan Installation .......................................................................................................... 25
6.1.1 Power Connections ......................................................................................................................... 25
6.1.2 Remote Control ............................................................................................................................... 26
6.2 Modbus Installation .............................................................................................................................. 27
6.2.1 Power and Control Connections ...................................................................................................... 27
6.2.2 Multi Fans Installation ...................................................................................................................... 29
6.2.3 Recommendations .......................................................................................................................... 30
7 MAINTENANCE ........................................................................................................................................... 31
8 TROUBLESHOOTING ................................................................................................................................. 32

AIRPRO [M]
4
SAFETY
Thank you for purchasing our products!
Please read this manual carefully before use, use the product accordingly and keep the manual in safe place.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes
and standards.
Before the installation, read the following warning and caution instructions:
WARNING!
Do NOT install, repair or clean the fan while it is in operation or connected to the power supply. Failure
to do so may result in serious injury or death.
Do NOT install, handle, repair or clean the fan with wet hands. Failure to do so may result in serious injury
or death.
Do NOT use wires with worn or damaged insulation. Doing so may result in serious or fatal electrical shock,
fire or other accidents.
Ensure that the wires are held securely and protected from abrasion, chaffing, overload or other
damage. Risk of serious or fatal electrical shock, fire or other accidents.
Turn Off power to the fan if you detect any damage. Risk of serious or fatal electrical shock, fire or other
accidents.
Do NOT connect a damaged fan to the power supply. Risk of serious or fatal electrical shock, fire or other
accidents.
CAUTION!
Use proper lifting equipment to handle the motor and blade boxes. Otherwise, the fan could be damaged
and there is risk of accident.
Follow the instructions and recommendations contained in this manual carefully. Failure to do so may
result in incorrect installation.

AIRPRO [M]
5
1 INTRODUCTION
The AIRPRO M series is a light fan of up to 34kg that can be installed in up to seven meters height ceilings. This
fan has been designed to be very easy to install. Depending on the control mode, the RF drive is integrated in the
brushless motor and the Modbus drive is located in the ceiling mount.
The main characteristics are:
EC brushless motor without gearbox
133mm ultra-thin motor
Extremely silent fans
7 aluminium blades
Optional customized paint
Remote control (RF) or Magnocontrol via Modbus
In addition, in combination with the traditional air conditioning systems, the use of fans allows generating important
energy savings of up 45% in winter and 25% in summer.

AIRPRO [M]
6
2 TECHNICAL CHARACTERISTICS
AIRPRO 250 M
AIRPRO 300 M
AIRPRO 350 M
AIRPRO 400 M
GENERAL CHARACTERISTICS
Diameter
2.5 m
3.0 m
3.6 m
4.0 m
Blades number
7
aluminium
b
lades
Standard colour
Black matte colour and aluminium blades
MOTOR
CHARACTERISTICS
Motor power
35
0W
35
0W
350W
350W
Supply voltage
20
0VAC ~
24
0VAC
I
, 50/60 Hz
Maximum consumption
335W/h
232W/h
176W/h
171W/h
Maximum consumption (A)
2.0 A
1.
5
A
1
.1
A
1
.1
A
Maximum speed
150rpm
1
0
0rpm
70
rpm
56
rpm
Protection degree
IP
55
IP
55
IP
55
IP
55
Sound level
<
40dBA
<40
dBA
<40
dBA
<40
dBA
Total wei
ght
25
kg
28
kg
31kg
34kg
Operation temperature
-
10ºC
~
50ºC without derating
Motor type
Brushless EC motor
FAN PERFORMANCE
Airflow*
81,645
m3/h
98,735
m3/h
120,925
m3/h
131,673
m3/h
Recommended coverage**
272
m²
329
m²
403
m²
440
m²
Maximum coverage***
381
m²
461
m²
564
m²
616
m²
CONTROL
Control
lers
Remote controller or Magnocontrol
OPTIONS
Extensions
Optional rod extensions of
1500 & 2000 mm
Colour
Optional paint or hydroprinting
Controller
Magnocontrol 10
-
25
REGULATION
Certifications
IECEE CB / BSMI
* Following AMCA 230-99 * Air Speed > 0.5 m/s ** Air Speed > 0.2 m/s

AIRPRO [M]
7
3 DIMENSIONS
The Anemoi Airpro [M] has four different diameters. The height of the fan can also be varied by changing the length
of the extension rod. The next figure shows the fan dimensions with an extension drop of 643 mm:
Model
D
A
B
H1
H2
H3
H4
2
50
M
2.5 m
350 mm 200 mm 643 mm 840 mm 1000 mm 133 mm
3
00
M
3.0 m
350 M
3.6 m
4
00
M
4.0 m

AIRPRO [M]
8
4 DELIVERY
The Anemoi Airpro [M] fan is delivered in two wood boxes, one including the motor parts and the other the blades.
Handle the fan boxes carefully and with proper lifting equipment to avoid any damage.
CAUTION!
Use proper lifting equipment to handle the motor and blade boxes. Otherwise, the fan could be damaged
and there is risk of accident.
4.1 Package Dimensions & Weights
The dimensions and weights of these boxes are listed in the following table:
Model
Box
WIDTH (mm)
DEPTH (mm)
HEIGHT (mm)
WEIGHT
(kg)
AIRPRO [M] Motor 760 760 500 29
Blades 1900 250 250 12
4.2 Packing List
The following tables include the different pieces sent inside the boxes. Please check the status and quantity of the
fan equipment and the supporting parts immediately after you have opened the box to make sure that the goods
received are in accordance with your order. If parts are missing or damaged, please inform our company's
responsible person immediately for revision.
Blades box:
NO. Component name QTY
1 Fan Blade 7 pcs
Motor box:
NO. Component name QTY
1 Motor 1 pc
2 Mounting Base 1 pc
3 Mounting Bracket 1 pc
4 Extension tube 1 pc
5 Extension tube shield 1 pc
6 Safety cable 1 pc
7 Wire rope clamp 20
8 Remote control (only remote-control option) 1
9 End caps 7
10 Bolts Box See below

AIRPRO [M]
9
NO. Component name QTY
1 Mounting Bracket shim
2 pcs
2 I beam shim
4 pcs
3 I beam clamp
2 pcs
4 Extension tube clamp
2 pcs
5 Guy wire bracket
2 pcs
6 Turn buckle
4 pcs
7 Beam clamp set
4 pcs
8 Ferrite Bead Clamp
1 pc
9 Earth Wire
1 pc
BOLTS
Connecting with
Screw standard
QTY
Mounting Base Bolt Kit M10*50 bolts 4
M10 Flat washer 8
M10 Spring washer 4
M10 Nut 4
Mounting Bracket M10*35 bolts 4
M10 Flat washer 8
M10 Spring washer 4
M10 Nut 4
Extension rod M10*70 bolts 3
M10 Spring washer 3
M10 Nut 3
Extension tube clamp M8*15 bolts 6
M8 Flat washer 6
M8 Spring washer 6
Motor tube M8*55 bolts 3
M8 Flat washer 6
M8 Spring washer 3
M8 Nut 3
Extension tube shield M6*16 bolts 4
End-caps M6*35 bolts 7
M6 Flat washer 14
M6 Spring washer 7
M6 Nut 7
Blades M6*35 bolts 21
M6 Flat washer 42
M6 Spring washer 21
M6 Nut 21

AIRPRO [M]
10
4.3 Fan diagram
A - Wire rope clamp
B - Safety cable
C - I beam clamp
D - I beam shim
E - Mounting base
F - Mounting bracket
G
-
Fixed angle mount bracket shim
H – Extension tube
I – Extension tube shield
J – Extension tube clamp
K – Guy wire bracket
L – Motor
M – End caps
N
-
Blades
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere ANEMOI Lüfter Handbücher

ANEMOI
ANEMOI AIRPRO L Bedienungsanleitung

ANEMOI
ANEMOI AIRSLIM L Series Bedienungsanleitung

ANEMOI
ANEMOI AIRLUX Bedienungsanleitung

ANEMOI
ANEMOI AIRMAX Bedienungsanleitung

ANEMOI
ANEMOI AIRPRO S Series Bedienungsanleitung

ANEMOI
ANEMOI AIRPOLE 250 Bedienungsanleitung

ANEMOI
ANEMOI AIRGO Bedienungsanleitung

ANEMOI
ANEMOI AIRSLIM 300M Bedienungsanleitung