AngelEye View Installation Guide
This guide refers to an AngelEye View with one underwater camera and one aerial camera. With an AngelEye
View with a higher number of underwater or aerial cameras, simply repeat the installation steps for the
number of cameras included.
Contents
1. Installation requirements
2. Definition of components
3. Installation
3.1 Installation of AngelEye underwater camera in the niche
3.2 Wiring of the AngelEye underwater camera
3.3 Preparation of the wiring of the aerial video camera
3.4 Wiring and installation of the aerial video camera
3.5 Installation of the light power supply
3.6 Wiring of the light power supply unit
3.7 Installation of the central unit
3.8 Wiring of the central unit

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 01/2023 – 1 | Page 2
Technology in The Service of Aquatic Safety
1. Installation requirements
• Locate a ventilated room that has a wall or surface for the installation of the central unit and allows
for easy cable arrival.
• Required tools:
o Drill with 5mm or 6mm diameter drill bit for wall mounting.
o Screwdriver with Phillips PH2 bit.
o Electrician's scissors
o Slotted screwdriver (flat) min. 1 x 5.5 mm
o Slotted screwdriver (flat) min. 0.8 x 3 mm
o Phillips screwdriver PH2
o Spirit level
• Material required not supplied:
o 1x multipole cable min 4 poles + ground 5 x 1.5mm2
o 2x power cables (3 x 2.5 mm2)
o 1x Ethernet cable cat. 6a or 7 for each camera supplied
o 1x 24v bipolar cable (2 x 1.5 mm2) for each underwater camera with integrated led lights
supplied
o Dowels, screws and washers for wall mounting of components
o Plastic cable ties
• Required connections:
o Two 230V power sockets
o One Internet outlet

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 01/2023 – 1 | Page 3
Technology in The Service of Aquatic Safety
2. Definition of components
AngelEye underwater camera
Aerial camera
Central unit
Light power supply
Junction box
RJ45 connector
Patch cable
Wago 1-pin connector

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 01/2023 – 1 | Page 4
Technology in The Service of Aquatic Safety
3. Installation
3.1 Installation of AngelEye underwater camera in the niche
1. Insert the black AngelEye cable from the AngelEye underwater camera inside the cable gland of the niche
ensuring that appropriate gain cable is coiled inside the niche in order to bring the camera to the surface
over the Trench Drain in case of maintenance.
2. Close the cable gland of the niche.
3. Secure the video camera inside the niche.
4. Attach the steel finish on the AngelEye underwater camera.

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 01/2023 – 1 | Page 5
Technology in The Service of Aquatic Safety
3.2 Wiring of the AngelEye underwater camera
1. Fix the junction box near the AngelEye underwater cable outlet corrugated using dowels.
2. Insert the AngelEye underwater cable coming from the AngelEye underwater camera, the Ethernet cat.
6a or 7 cable outgoing to the central unit, and the 24v bipolar cable (2 x 1.5 mm2) outgoing to the light
power supply into the cable glands of the junction box.
3. Carry out inside the junction box, the installation of RJ45 connectors on the underwater cable and
Ethernet cable respecting the A standard.

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 01/2023 – 1 | Page 6
Technology in The Service of Aquatic Safety
4. Apply the patch between the two M/M connectors.
5. Wire the electrical cables between the low voltage (24VDC) cables coming from the light power supply
and the brown and blue cables inside the underwater cable.

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 01/2023 – 1 | Page 7
Technology in The Service of Aquatic Safety
6. Tighten the cable glands and close the junction box.

Sant’Osvaldo 1b - 39100 Bolzano - Italy
www.angeleye.tech
+39 0471 1726038
AngelEye Ltd. | Ver: 01/2023 – 1 | Page 8
Technology in The Service of Aquatic Safety
3.3 Preparation of the wiring of the aerial video camera
1. Place an Ethernet cat. 6a or 7 cable for wiring the cameras by positioning one end near the location
identified for placement of the central unit and the other end near the location identified for placement
of the aerial camera. Be sure to have appropriate gain wire on both ends of the cable to make the
connection of RJ45 connectors.
2. Carry out the installation of an RJ45 connector on the end of the Ethernet cat. 6a or 7 cable near the
location identified for the placement of the aerial camera respecting the A standard.
3. Repeat the procedure given in steps 1. and 2. for the number of aerial cameras provided.