Anolis ArcPower 384 Bedienungsanleitung

version 1.6

2
Table of contents
1. Important safety instructions........................................................................................3
1. Consignes de sécurité importantes..............................................................................4
2. Operating determinations..............................................................................................4
3. Description of the ArcPower 384 Rack Mount............................................................. 5
4. Conguration of terminals ..................................................................................................... 6
5. Installation.......................................................................................................................6
5.1 Connection to the mains ............................................................................................ 6
5.2 Installing the ArcPower 384 Rack Mount into the rack............................................... 7
6. DMX 512 operation .........................................................................................................7
7. Ethernet operation..........................................................................................................8
8. ArcPower 384 Rack Mount - Control menu map ....................................................... 10
9. ArcPower 384 Rack-Mount - DMX protocol ............................................................... 13
10. Fixture menu...............................................................................................................17
10.1 Fixture Address ..................................................................................................... 17
10.2 Fixture information ................................................................................................. 18
10.3 Personality ............................................................................................................. 19
10.4 Test sequences ...................................................................................................... 20
10.5 Manual mode ......................................................................................................... 20
10.6 Stand-alone setting .............................................................................................. 20
10.7 Special Functions................................................................................................... 21
11.Technical Specications:............................................................................................22
12. Maintenance ............................................................................................................... 24
12.1 Replacing the air lters........................................................................................... 24
12.2 Replacing the main fuse......................................................................................... 24
ArcPower 384 Rack-Mount

3
CAUTION!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
ATTENTION!
Débrancher l’appareil avant d'ouvrir le boîtier!
POUR VOTRE SÉCURITÉ, LISEZ ATTENTIVEMENT CETTE NOTICE AVANT LA PRE-
MIERE UTILISATION
1. Important safety instructions
Every person involved with installation and maintenance of this product has to:
- be qualiled
-follow all instructions and heed all warnings in this manual
CAUTION!
Be careful with your operations. With a high voltage you can suer
a dangerous electric shock when touching the wires inside the unit!
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this manual.
WARNING
To prevent injury, this apparatus must be securely attached to a rack in accordance
with the installation instructions.”
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
ampliers) that produce heat.
Do not use this apparatus near water. Clean only with dry cloth.
MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain
readily operable.
Only use attachments/accessories specied by the manufacturer.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged
in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Use a source of AC power that complies with local building and electrical rules.AC power has to have both
overload and short circuit protection.
This device falls under protection class I.Therefore the ArcPower 384 Rack Mount
has to be connected to a mains socket outlet with a protective earthing connection!

4
1. Consignes de sécurité importantes
Toute personne impliquée dans l'installation et la maintenance de ce produit doit:
- Être susamment qualié
- Suivre les instructions de ce manuel
ATTENTION!
Soyez prudent avec vos manipulations. Avec une haute tension, vous risquez un
choc électrique en touchant les ls à l'intérieur de l'appareil!
Ce produit a quitté nos ateliers dans un état irréprochable. An de maintenir cet état et pour assurer un bon
fonctionnement, il est absolument nécessaire de suivre les consignes de sécurité et les notes contenues dans
ce manuel.
AVERTISSEMENT
Pour éviter toute blessure, cet appareil doit être solidement xé à un support en
conformité avec les instructions d'installation. "
Ne pas bloquer les ouvertures de ventilation. Installer conformément aux instructions du fabricant.
Ne pas installer près de sources de chaleur telles que radiateurs, ou autres appareils (y compris les ampli-
cateurs) produisant de la chaleur.
Ne pas utiliser cet appareil près de l'eau. Nettoyer avec un chion sec.
Une prise de branchement ou un coupleur est utilisé comme dispositif de déconnexion, ce dispositif doit rester
facilement accessible.
N'utilisez que des accessoires spéciés par le fabricant.
Protégez le cordon d'alimentation du piétinement ou pincement, particulièrement au niveau des ches, des
prises, et le point où ils sortent de l'appareil
Conez toute réparation à un personnel qualié. Une réparation est nécessaire lorsque l'appareil a été endo-
mmagé de quelque façon que ce soit. cordon d'alimentation, che est endommagé, liquide renversé a l interieur,
ou des objets sont tombés dans l'appareil, l'appareil a été exposé à la pluie ou à l'humidité, ne fonctionne pas
normalement , ou s'il est tombé.
Utilisez une source de courant alternatif qui est conforme a l’endroit ou vous vous trouvez. La source alternative
doit avoir à la fois une protection de surcharge et de court-circuit.
Ce dispositif relève de la classe de protection I. Par conséquent, la ArcPower 384
rack mount doit être connecté à une prise électrique reliée à la terre!
2. Operating determinations
This product was designed for indoor use only.
If the unit has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your unit. Leave the unit switched o until it has
reached room temperature.
Avoid brute force when installing or operating the unit.
When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture
or dust.
Only operate the unit after having checked that the housing is rmly closed and all screws are tightly fastened.

5
The maximum ambient temperature 40° C must never be exceeded.
Operate the unit only after having familiarized with its functions. Do not permit operation by persons not qualied
for operating the unit. Most damages are the result of unprofessional operation!
Please use the original packaging if the product is to be transported.
Please consider that unauthorized modications on the unit are forbidden due to safety reasons!
3. Description of the ArcPower 384 Rack Mount
1- LCD graphic displayr
2- ANS rotary wheel
3- Enter button
4- Escape buttont
5- Cooling fans
1- Fuse holder
2- Mains input
3 - DMX IN/OUT (3-pin XLR)
4 - DMX input for DyNet (RJ45)
5 - Control port (RS 232)
6 - LED Zones 1-8 (8 x RJ45)
7 - Ethernet (RJ45)
8 - DMX IN/OUT(5-pin XLR)

6
4. Conguration of terminals
DMX output DMX input
XLR mounting sockets (rear view) XLR mounting plugs (rear view)
1 – Shield 2 - Signal (-) 3 - Signal (+) 4 – Not connected 5 – Not connected
DyNet input Ethernet
RJ 45 female (rear view) RJ 45 female (rear view)
Control port (RS232) LED output zone
DE-9 (male) RJ 45 female (rear view)
5. Installation
5.1 Connection to the mains
CAUTION!
These servicing instructions are for use by qualied service personnel only. To
reduce the risk of electric shock do not perform any servicing other than that con-
tained in the operating instructions unless you are qualied to do so.
The ArcPower 384 Rack Mount is equipped with auto-switching power supply that automatically adjusts to any
50/60Hz AC power source from 100-240 Volts.
The fixture is equipped the cord & plug QP 02 but you can use the following plugs:
P620,24W47,14W49,24W49,26W81,HBL4720C,HBL2311, HBL2321,HBL2811 and the cords SJT or 22326.
Pin 1: Not connected Pin 5: Not connected
Pin 2: +12V Pin 6: Data +
Pin 3: Not connected Pin 7: Data -
Pin 4: Not connected Pin 8: GND
Pin 1: Not connected
Pin 2: Received Data
Pin 3: Transmitted Data
Pin 4:
Pin 5: Signal Ground
Pin 6:
Pin 7:
Pin 8:
Pin 9: Not connected
Pin 1: Red LEDs + Pin 5: Red LEDs -
Pin 2: Green LEDs + Pin 6: Green LEDs -
Pin 3: Blue LEDs + Pin 7: Blue LEDs -
Pin 4: White LEDs + Pin 8: White LED -
Pin 1: TX+ Pin 5: Not connected
Pin 2: TX- Pin 6: RX-
Pin 3: RX+ Pin 7: Not connected
Pin 4: Not connected Pin 8: Not connected

7
Cord plug connections:
Cable (EU) Cable (US) Pin International
Brown Black Live L
Liht blue White Neutral N
Yellow/Green Green Earth
5.2 Installing the ArcPower 384 Rack Mount into the rack
The ArcPower 384 Rack Mount is designed for the mounting into 19- inch equipment rack.
The hight of the xture matches 2U size. Installing the ArcPower 384 Rack Mount involves following steps:
1. Mount the rails into the equipment rack.
2. Install the rails onto the ArcPower 384 Rack Mount unit.
3. Slide the the ArcPower 384 Rack Mount into the rack and secure it in this positione by tightening the 2 screws
on each side of the ArcPower 384 front panel.
Note: If the equipment rack is badly ventilated , we recommend to mount the 2 spacers (1U size) on both sides
of the ArcPower 384 as shown on the picture to ensure free space under and over the unit.
6. DMX 512 operation
The ArcPower 384 Rack Mount is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.
Only use a shielded twisted-pair cable designed for RS-485 and 3-pin/5-pin XLR- connectors in order to connect
the xture with the DMX controller or one xture with another.

8
To build a DMX chain.
1. Unplug xtures from the mains before installation.
2. Connect the LED modules to the xtures.You cannot combine RGB and RGBW modules
(e.g. ArcSource 6 RGB and ArcSource 7 RGBW) on the same LEDs output.
3. Connect the DMX controller to the rst xture
4. Connect xtures each other. Max. 32 xtures may be connected on a DMX link. Terminate the DMX link
by installing a termination plug in the output of the last xture. The termination plug is a male 3-pin/5-pin
XLR plug with a 120 Ohm resistor soldered between Signal (–) and Signal (+).
5. Connect xtures to the mains
6. Set desired DMX address on each xture (see the chapter "Control board").
Note: You cannot combine RGB andRGBW modules on one LED output as the current circle of the white LEDs
will not be closed ( white LEDs will not lit). All modules have to be either RGB or RGBW on one LED output..
7. Ethernet operation
The xtures on a data link are connected to the Ethernet network with an Art-Net communication protocol. The
control software from PC (or lighting console) has to support the Art-Net protocol.
The Art-Net communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP. Its purpose is to
allow transfer of large amounts of DMX 512 data over a wide area using standard network technology.
An IP address is Internet protocol address. The IP uniquely identies any node (xture) on a network.
The Universe is a single DMX 512 frame of 512 channels.
The ArcPower 384 Rack Mount is equipped with 8-pin RJ- 45 socket for Ethernet input. Use a network cable
category 5 (with four “twisted” wire pairs) and standard RJ-45 plugs in order to connect the xture to the network.
Patch cables that connect xtures to the hubs or LAN sockets are wired 1:1, that is, pins with the
same numbers are connected together:

9
1-1 2-2 3-3 4-4 5-5 6-6 7-7 8-8
If only the xture and the computer are to be interconnected, no hubs or other active components are needed.
A cross-cable has to be used:
1-3 2-6 3-1 4-8 5-7 6-2 7-5 8-4
All xtures have to be connected to Ethernet via standard patch cables and a data switch.
The option “ Ethernet” has to be selected from the “Set Ethernet Mode” menu on each xture.
Set correct IP address and the Universe for each xture.

10
8. ArcPower 384 Rack Mount - Control menu map
Default settings=Bold print
Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6
Fixture Address DMX Address 001-512
Dynet Zone 1-255
Ethernet Settings Set Ethernet Mode Disable Ethernet
Ethernet
Set IP Address Default IP Address
Custom IP Address
Set ArtNet Universe 0-255
Fixture Information Power On Time Total Hours
Resetable Hours
Air Filters Set Alert Period 10...50...300 hours
Elapsed time
Fixture temperature Current Board 1 Temp.
Board 2 Temp.
Max. Nonresetable Board 1 Temp.
Board 2 Temp.
Maximum Resettable Board 1 Temp.
Board 2 Temp.
DMX Values Red LEDs 1 0-255
:
Dimmer 0-255
Software Version IC1 MB1
IC2 MB1
IC1 MB2
IC1 DS
IC2 DS
Product IDs Mac Adr.
RDM UID
Personality User Mode User A Settings
User B Settings
User C Settings
DMX Preset Mode 1 Ch.1 Red LEDs 1
:
Ch. 24 Blue LEDs 8
Set Active
Mode 2 Ch.1 Red LEDs 1
:
Ch.32White LEDs 8
Set Active
Mode 3 Ch.1 Red LEDs 1
:
Ch.35 Dimmer
Set Active
Mode 4 Ch.1 Red LEDs 1
:
Ch. 4 Dimmer
Set Active
Mode 5 Ch.1 Red LEDs 1
Inhaltsverzeichnis
Beliebte Rack & Stand Handbücher anderer Marken

Salamander
Salamander Acadia AC/W/L400/WH Bedienungsanleitung

Fohhn
Fohhn VAT-09 Benutzerhandbuch

ricoo
ricoo FS0522 Bedienungsanleitung

AMSOIL
AMSOIL BMK-22 Kurzanleitung

Kargo Master
Kargo Master 48220 Bedienungsanleitung

Milestone AV Technologies
Milestone AV Technologies SIMPLICITY SLF2 Bedienungsanleitung