Page 4 BK743
Ecoburn (S3) Gas CF Stove Installaon and Servicing
SECTION 1 : APPLIANCE INFORMATION
1.1 - Conditions Of Installation
Before installation, check that the local distribution conditions, nature of the gas and pressure, and adjustment
of the appliance compatible. It is the law that only a competent person installs all gas appliances ie: a gas
registered installer in accordance with the current edition of the gas safety (installation and use) regulations or
the rules in force, failure to do so could lead to prosecution.
The installer must be gas safe registered.
The installation must also be in accordance with all relevant parts of the local and national buildings
regulations where appropriate, the building regulations (Scotland consolidation) issued by the Scottish
development department, and all applicable requirements of the following standard codes of practice :
1. BS 5871 part 1
2. BS 6891 installation of gas pipework
3. BS 5440 parts 1 & 2 installation of flues and ventilation
4. BS 8303 installation of domestic heating appliances
5. IS 813 Domestic gas installation (Republic Of Ireland)
No purpose made additional ventilation is normally required for this appliance when
installed in G.B. When installing in I.E. please consult document IS 813 domestic gas
installation, which is issued by the national standards authority of Ireland, if installing in
Northern Ireland please consult local building regulations. In Scotland, please consult
the current edition of the building standards regulations, issued by the Scottish
executive. Any purpose made ventilation must be checked periodically to ensure that it
is free from obstruction.
PLEASE NOTE—The stove is a very heavy appliance and care must be used when lifting and moving, we
recommend 2 people lift following lifting guidelines. Preferably wear gloves when lifting.
Model
Gas Type G20 (Natural Gas) G31 (Propane) G30 (Butane)
Supply Pressure (Measured At Test Elbow), (mbar) 20 37 29
Injector (x1) Stereomatic 320 Stereomatic 120 Stereomatic 120
Oxypilot Type Erta PG-82-330 Erta PG-82-350 Erta PG-82-350
Nominal Heat Input (Qn), kW (Gross) Maximum Rate 54.4 4.5
Gas Consumption At Maximum Rate, (m3/h) 0.47 0.157 0.121
Minimum Heat Input, kW (Gross) 2.3 1.8 2.7
Gas Consumption At Minimum Rate, (m3/h) 0.22 0.061 0.074
Gas Connection 8mm Compression 8mm Compression 8mm Compression
Remote Gas Valve TESC01 RF868-15 TESC01 RF868-15 TESC01 RF868-15
Countries Of Destination GB & IE GB & IE GB & IE
Efficiency Class 1 BBB
NOX 95mg/kWH 97mg/kWH 98mg/kWH
Ecoburn (S3) Gas