SECTION 1 : APPLIANCE INFORMATION
BK 710 Specific Page 4
Ecoburn Plus Gas
Model ARADA ECOBURN PLUS
Gas type G20 (natural gas)
Supply pressure (measured at test elbow), mbar 20
Injector (x1) Stereomatic 500
Oxypilot type Erta PG-82 -10
Nominal Heat Input (Qn), kW (Gross)-Maximum Rate 6.2
Gas consumption at max rate (m3/h) 0.590
Minimum heat input Kw (Gross) 2.5
Gas consumption at minimum rate (m3/h) 0.238
Gas connection 8mm compression
Remote gas valve TESCO1 RF868-15
Countries of Destination GB and IE
Efficiency class 1
NOX 2
1.1 - Conditions Of Installation
Before installation, check that the local distribution conditions, nature of the gas and pressure, and adjustment
of the appliance compatible. It is the law that only a competent person installs all gas appliances i.e.: a gas
registered installer in accordance with the current edition of the gas safety (installation and use) regulations or
the rules in force, failure to do so could lead to prosecution.
The installer must be gas safe registered.
The installation must also be in accordance with all relevant parts of the local and national buildings regula-
tions where appropriate, the building regulations (Scotland consolidation) issued by the Scottish development
department, and all applicable requirements of the following standard codes of practice :
1. BS 5871 part 1
2. BS 6891 installation of gas pipework
3. BS 5440 parts 1 & 2 installation of flues and ventilation
4. BS 8303 installation of domestic heating appliances
5. IS 813 Domestic gas installation (Republic Of Ireland)
No purpose made additional ventilation is normally required for this appliance when in-
stalled in G.B. when installing in I.E. please consult document IS 813 domestic gas in-
stallation, which is issued by the national standards authority of Ireland, if installing in
Northern Ireland please consult local building regulations. In Scotland, please consult
the current edition of the building standards regulations, issued by the Scottish
executive. Any purpose made ventilation must be checked periodically to ensure that it
is free from obstruction.
PLEASE NOTE—The stove is a very heavy appliance and care must be used when lifting and moving, we
recommend 2 people lift following lifting guidelines. Preferably wear gloves when lifting.