ARAG Bravo 3 Series Bedienungsanleitung

BRAVO 3XX
SOFTWARE 60 VERSION
ADDITION TO INSTRUCTION BOOKLET CODE D20033.GB

This manual is an integral part of the device to which it refers and must always accompany it, even
in case of sale or transfer. Keep it for future reference; ARAG reserves the right to modify the spe-
cifications and instructions regarding the product at any time and without prior notice.
2

3
Contents
1 INTRODUCTION................................ 4
1.1 New functions .......................................4
2 SETTINGTHEFUNCTIONS.......................... 5
2.1 Setting the minimum and maximum nozzle pressure alarms ...............5
2.2 Incorrect operating pressure signal ............................6
2.3 Setting the minimum speed of adjustment ........................7
2.4 Setting the minimum speed for the automatic closure of the main valve .........8
2.5 Calibration of 0 for the pressure transducer .......................10
2.6 Resetting the liquid present in the tank .........................11
2.7 Display of the "FIELD 0" counters ............................12
2.8 Pump failure signal ...................................13
3 MULTIROW SPRAYER PROGRAMME FUNCTIONS . . . . ........14
3.1 Main differences compared to the version for the spraying machine ..........14
3.2 Programming of the flow rate for the sectors ......................15
3.3 Selection of the flow rate of the sectors .........................16
3.4 Setting the operating widths ...............................17
3.5 Selection of the operating width .............................18
3.6 Setting the operating programmes ........................... 19
3.7 Selection of the operating programmes .........................20
4 ORCHARD SPRAYER PROGRAMME FUNCTIONS. . . . . . . . . . . . . 21
4.1 Main differences compared to the version for the spraying machine ..........21
4.2 Programming the flow rate of the sprayer booms ....................22
4.3 Selection of the flow rate of the sprayer booms .....................23
4.4 Selection/modification of row distance .........................24
4.5 Configuration of operating programmes .........................25
4.6 Selection of operating programmes ........................... 26
4.7 Signalling of ambiguous section opening ........................26

English
1 INTRODUCTION
This introduction booklet explains the different functions of the 60 software compared to the 54 software.
The main changes in the software affect operation when the BRAVO 3XX computer is set as a multi-row
sprayer or orchard sprayer.
1.1 New functions
The main changes are:
• Setting the minimum and maximum nozzle pressure alarms (section 2.1):
the minimum and maximum pressures can be set for correct operation of each nozzle: the computer will
trigger an alarm signal outside these limits.
• Setting the minimum speed for adjustment (Menu 191.0 section 2.3):
It is possible to set a minimum speed so that automatic adjustment will not triggered below it.
This makes it possible to remain within a range of pressure so that the nozzles always provide effective
coverage.
IATTENTION: below this speed, dosing no longer corresponds to the preset amount
•Setting the minimum speed for the automatic closure of the main valve
(Menu 191.0 - 192.1 section 2.4):
it is possible to set a speed so that the main valve will be closed automatically below this (only for
systems with separated unit, item code 46732XX)
IATTENTION: this function AUTOMATICALLY excludes the setting of the minimum adju
-
stment speed (Menu 191.0 section 2.3)
•Incorrect operating pressure signal (section 2.2):
the computer triggers an alarm signal when the nozzle operating pressure does not correspond to the
preset level.
• Calibration of 0 for the pressure transducer (section 2.5):
the reading of 0 of the pressure transducer can be calibrated, if necessary.
• Resetting the liquid present in the tank (section 2.6):
the quantity of liquid in the tank can be reset rapidly.
• Display of the "FIELD 0" counters (section 2.7):
it is possible to display the data with more than 4 or 5 digits relating to field 0 (field can not be reset).
•Pump failure signal (section 2.8):
when the sensor signals pump failure, the computer triggers a visual and acoustic alarm signal.
4

English
2 SETTING THE FUNCTIONS
2.1 Setting the minimum and maximum nozzle pressure alarms
1) Keep pressed until you
access menu 1.0
2) Press to select
menu 4.0
(see following illustration)
MENU 4.0
3) Press to select the
nozzle whose pressure
alarms require setting
4) Keep pressed until you
access the menu for
setting the alarms relative
to the nozzle selected
(see following illustration)
FOLLOWING
5

5) Press to access
modification of the
minimum pressure level,
below which an alarm will
be triggered (visual and
acoustic)
6) Press to access
modification of the
maximum pressure level,
above which an alarm will
be triggered (visual and
acoustic)
7) Press to return to
menu 4.0
During data modification:
A) Press to modify the data
you are setting
B) Press to confirm the new
data entered
2.2 Incorrect operating pressure signal
Should the operating
pressure be above or below
the limits set for the nozzle
in operation, the two
symbols will flash and an
acoustic signal will be
heard
English
6

2.3 Setting the minimum speed of adjustment
1) Keep all the buttons
pressed together in order to
access advanced user
programming
2) Press to set code 76
3) Press to confirm the
code
MENU 191.0
1) Press to set the value for
the minimum speed, below
which automatic adjustment
will be blocked
2) Set the required value
3) Press to confirm the data
4) Press to return to the
main menu
5) Switch the computer off
and on again for the
settings to take effect
English
7

2.4 Setting the minimum speed for the automatic closure of the main valve
1) Keep all the buttons
pressed together in order to
access advanced user
programming
2) Press to set code 76
3) Press to confirm the
code
MENU 191.0
1) Press to set the value for
the minimum speed (km/h
or mph), below which
automatic delivery will be
closed
2) Set the required value
3) Press to confirm the data
English
8

1) Press to select
menu 192.1
MENU 192.1
1) Press to set the delay
(in sec) for the closure of
the main valve: after the
speed has dropped below
the minimum value set in
menu 191.0, the computer
will close the main valve
after the delay, set
previously, is over.
ATTENTION:
If the value 0 is set,
automatic closure of the
valve is cancelled
2) Set the required value
3) Press to confirm the data
4) Press to return to the
main menu
5) Switch the computer off
and on again for the
settings to take effect
English
9

2.5 Calibration of 0 for the pressure transducer
1) Keep pressed until you
access the calibration
menu for the calibrated
returns
(see following illustration)
2) Press to access the 0
calibration menu for the
pressure transducer
(see following illustration)
ATTENTION: If the
computer has not been
programmed to manage
calibrated returns, the
display here aside will not
appear and you will go
directly to the pressure
transducer calibration
menu
(see following illustration)
3) Press until the acoustic
signal is heard confirming
that calibration of the
pressure transducer has
been completed
ATTENTION: Make sure
the pressure of the
system is zero before
starting calibration.
4) Press to return to the
main menu
English