Balcrank FUSION 3110-013 Bedienungsanleitung

SERVICE BULLETIN SB3059
Rev A 12/08
Thoroughly read and understand this manual before
installing, operating or servicing this equipment.
OPERATION, INSTALLATION,
MAINTENANCE AND REPAIR GUIDE
FUSION
MASTER KEYPAD
®
Model 3110-013

Disclaimer
The user/purchaser is expected to read and understand the information provided in this
manual, follow any listed Safety Precautions and Instructions and keep this manual with the
equipment for future reference.
The information in this manual has been carefully checked and is believed to be entirely
reliable and consistent with the product described. However, no responsibility is assumed
for inaccuracies, nor does Balcrank Products, Inc. assume any liability arising out of the
application and use of the equipment described.
Should the equipment be used in a manner not specied by Balcrank Products, Inc., the
protection provided by the equipment may be impaired.
Questions or Service Assistance
If you have questions regarding the product or this document contact:
Balcrank Products, Inc.
115 Reems Creek Rd.
Weaverville, NC 28787
Telephone: (828) 645-4261
(800) 747-5300
Fax: (828) 658-0840
(800) 763-0840
On the Web: www.balcrank.com
or call your local Balcrank Products, Inc. representative.
Product Identication Information
Record the product identication numbers from the nameplate here.
Model Number _______
Serial Number _____________
Tag Number _______________(if applicable)

Table of Contents
Disclaimer ..................................................................................................Inside Front Cover
Questions or Service Assistance ...............................................................Inside Front Cover
Product Identication Information ..............................................................Inside Front Cover
Table of Contents ................................................................................................................. 3
BEFORE YOU BEGIN ..........................................................................................................4
Product Unpacking and Inspection ....................................................................................4
MOUNTING MASTER KEYPAD ...........................................................................................5
SPECIFICATIONS ................................................................................................................5
FCC Certication ...............................................................................................................5
MASTER KEYPAD CONNECTIONS ....................................................................................6
DESCRIPTION of MASTER KEYPAD KEYS .......................................................................7
SYSTEM CONFIGURATIONS ..............................................................................................8
Default Screen Display ......................................................................................................8
Set Time and Date .............................................................................................................9
CONFIGURATION of WORK ORDER VALIDATION …..............…………………...……….10
CONFIGURATION of DISPENSE RESULTS ARCHIVING ................................................11

4
BEFORE YOU BEGIN
Product Unpacking and Inspection
NOTE: If damage to the shipping container is evident upon receipt, request the carrier
to be present when the products are unpacked
Upon receipt of the products, perform the following unpacking and inspection procedures:
Follow any instructions that may be marked on the exterior. Carefully open the shipping
package. Remove all cushioning material surrounding the products and carefully lift the
products from the package.
Retain the package and all packing material for possible use in reshipment or storage.
Visually inspect the products and applicable accessories for any physical damage such as
scratches, loose or broken parts, or any other sign of damage that may have occurred
during shipment.
NOTE: If damage is found, request an inspection by the carrier’s agent within 48 hours
of delivery and le a claim with the carrier. A claim for equipment damage in tran
sit is the sole responsibility of the purchaser.

MOUNTING MASTER KEYPAD
The Master Keypad should be mounted upright with the antenna pointing upward, near a
120VAC electrical outlet.
The Keypad should be mounted to a structurally sound wall using the three holes in the
Keypad back plate. Mounting height should be 5 to 6 feet for consistent access.
Care should be taken to avoid mounting the keypad behind any steel objects that may
block
the RF signals from Hoses/Meters.
Care should be taken to avoid direct, signicant, heat sources.
NOTE: Master Keypad should not be mounted within 20 feet of a Dispense Keypad.
Specications
Power Requirements: 120VAC 50/60Hz
RF Communications: 2-way, 902-928MHz Frequency Hopping Spread Spectrum per FCC
Operating Temperature: 14° F to +140° F (-10° C to +60° C)
FCC ID: GIF-RF KEYPAD
FCC CERTIFIED, PART 15, SUB-PART C
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired opera-
tion.
7
7
3
5
8
3
8
13
16
7
7
3
5
8
3
8
13
16
MOUNTING DIMENSIONS FOR KEYPAD
(HOLES ON KEYPAD ARE THREADED FOR A M6 x 1 SCREW)
5
Keypad Mounting Dimensions
(Holes on Keypad are threaded for a M6X1 screw)

6
MASTER KEYPAD CONNECTIONS
9-Pin
PC Connector
Serial Connection to
Host
(no markings on cable)
“O” indicates Cable to
Optional Printer
There are two nine-pin cables on the bottom of the Master Keypad.
The cable without any markings is the Serial Connection to the Host.
The cable marked with an “O” is for connection to an Optional Printer.
There is a nine pin connector on the bottom of the Master Keypad for connection to the PC.
An AC cord is also attached here.
Connections
Master Keypad Plugs (9-pin) RS-232 Host or PC Plug (9-pin) RS-232
Pin No. 2 (TXD) ......................................Pin No. 3 (RXD)
Pin No. 3 (RXD)......................................Pin No. 2 (TXD)
Pin No. 7 (GND) .....................................Pin No. 7 (GND)
Maximum cable length: at 1200 Baud = 492 feet (150m)
at 9600 Baud = 328 feet (100m)

7
Description of Central Control Keypad Keys
Keypad Screen
Keypad Keys
Master
Keypad
Scroll Key: Used to select options on the active display
Home Key: Pressing this key returns the display to the default screen display
Backspace Key: Used to backspace when entering data
Enter Key: Used to enter data and move to the next screen
Space Key: Used to enter a space character when entering data
Alphanumeric Keys: Used to enter numbers and letters
on the display.
Hold the key down until the desired letter is displayed
(approximately three (3) seconds). Then release the
key.

8
SYSTEM CONFIGURATION
The PC is used to congure the system entities. The system conguration is then sent from
the PC to the master keypad which then sends the system conguration to the keypads via
RF communications.
The Master Keypad handles the communications management between the PC, Host, and
the Dispense Keypads. There are no operator menus associated with the Master Keypad.
The Master keypad provides the date and time stamp for all transactions within the system.
It is required that the date and time be set on the Master keypad for accurate tracking.
The Master keypad must also be congured for work order verication and dispense result
archiving. The default setting for both functions is performed at the PC.
Work order verication can be done by the PC or host (DMS) system. There is also an
optional setting to not verify work orders.
Dispense result archiving can be selected to be done at the PC. If the host protocol is used,
the PC can be selected to not archive or can also be used to archive in parallel.
Default Screen Display
The “Default” screen shows the system date, time, and soft-
ware version number for information purposes only.
The screen display alternates between the “Default” screen (above) and the “Enter Pin No.”
screen (below). The “Enter Pin No.” screen displays for four (4) seconds out of every ve
(5) seconds.
The “Enter Pin No.” screen is used by the Supervisor to
access the system setup screens.
The Supervisor Pin Number is initially 0000 and must be
changed from the PC.

9
Setting the Time and Date
The Master Keypad provides the time and date stamp for each WO result.
The Time and Date must be set on the Master Keypad before the system can be used.
1. On the Master Keypad enter the Supervisor Pin No. (default
0000) and press the Check box .
2. The cursor will be on INI, press the Check box to select.
1. Enter the time of day in military time. Example: 10:52 for 10:52
a.m. and 13:03 for 1:03 p.m.
2. Press the Check box to set the time.
1. Enter the two (2) digit day of the month.
2. Use the Scroll key to scroll to the current month.
3. When the current month is displayed, enter the four (4)-digit year.
4. Press the Check box to set the date.
Enter Time screen appears.
Enter Date screen appears.

10
CONFIGURATION of WORK ORDER VALIDATION
1. On the Master Keypad enter the Supervisor Pin ID (default 0000) and press Enter
2. Use the Scroll key to move the cursor to CNF.
3. Press Enter to select the CNF menu.
4. Continue to press Enter until the “WO Valid. Host”
screen displays.
Use the Scroll key to select NO.
Press the Check box .
5. Continue to press Enter until the “WO Valid. PC”
screen displays.
Use the Scroll key to select YES or NO to have work
orders validated from the PC.
Press the Check box .
Press the Home key to return the display to the default screen.
Andere Handbücher für FUSION 3110-013
1
Inhaltsverzeichnis
Andere Balcrank Tastenfeld Handbücher