Baxi Firefox 5 910 Montageanleitung

© Baxi Heating U.K. Limited 2007.
5122664/01
INSTALLER GUIDE
INSTALLER: Please leave this guide with the owner
THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20).
WHEN CONVERTED USING CONVERSION KIT NO. 0591011
THIS APPLIANCE
IS FOR USE WITH PROPANE GAS (G31).
THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED
KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE).
Firefox5
Model 910
CAST-IRON GAS STOVE
Fitted with a Ceramic Coal fuel effect.
(GC No. 32-264-24)
For technical advice firstly contact your retailer.
If further advice is required then call 01204 868550.

© Baxi Heating U.K. Limited 2007.
All rights reserved. No part of this publication may be reproduced in any material form
(including photocopying), stored in any medium by electronic means (including in any
retrieval system or database) or transmitted, in any form or by any means, whether
electronic, mechanical, recording or otherwise, without the prior written permission of
the copyright owner.
Applications for the copyright owner's permission to reproduce any part of this
publication should be made, giving details of the proposed use, to the following
address: The Company Secretary, Baxi Heating UK Limited, The Wyvern Business
Park, Stanier Way, Derby, DE21 6BF.
Warning: Any person who does any unauthorised act in relation to a copyright work
may be liable to criminal prosecution and civil claims for damages.
Valor Fires, Erdington, Birmingham B24 9QP
Because our policy is one of constant development and improvement, details may vary slightly from
those given in this publication
LIST OF CONTENTS
Heading Page
1. SAFETY 3
2. APPLIANCE DATA 4
3. UNPACKING 5
4. STOVE SET UP 6
5. GENERAL INSTALLATION REQUIREMENTS 9
6. OPERATING THE STOVE 12
7. FINAL REVIEW AND SERVICING 14
Page 2
INSTALLER GUIDE
© Baxi Heating U.K. Limited 2007.

Page 3
INSTALLER GUIDE
1. SAFETY
Installer
Firefox stoves are efficient appliances giving off convected, conducted and radiated
heat. All the surfaces of the stove - except the controls - are working surfaces and
become hot in use. They must not be touched or have any combustible objects or
materials placed on or near them. A fire guard complying with BS 8423 should be
fitted for the protection of young children, the elderly, the infirm or pet animals.
The appliance is fitted with a flue safety device. If the appliance closes down after a
period of operation for no apparent reason, the consumer should be informed to stop
using the appliance until the installation and appliance have been thoroughly
checked. Under no circumstances should the flue safety device be altered or
bypassed in any way. Only a genuine manufacturers replacement part should be
fitted.
Before continuing any further with the installation of this appliance please read the
following guide to manual handling:
!The lifting weight of this appliance is 55 kg. We therefore recommend that two
people should be sufficient to lift the stove. If fitting or moving the stove alone we
recommend the use of suitable lifting apparatus.
!When lifting always keep your back straight. Bend your legs and not your back.
!Avoid twisting at the waist. It is better to reposition your feet.
!Avoid upper body/top heavy bending. Do not lean forward or sideways whilst
handling the stove.
!
Always grip with the palm of the hand. Do not use the tips of fingers for support.
!Always keep the stove as close to the body as possible. This will minimise the
cantilever action.
!Use gloves to provide additional grip.
!Always use assistance if required.
© Baxi Heating U.K. Limited 2007.

Page 4
INSTALLER GUIDE
© Baxi Heating U.K. Limited 2007.
2. APPLIANCE DATA
*When converted using kit 0591011.
The appliance information label is located on a plate at the base of the stove.
The efficiency of this appliance has been measured as specified in BS EN 613 and
the result is as below :
Model
Efficiency % (Gross)
910 73.1
910 when converted to LPG. 73.1
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
Gas Conversion factor from net to gross efficiency
Natural Gas 0.901
LPG 0.921
Gas Natural (G20) Propane (G31) *
Inlet Pressure 20mbar 37mbar
Input - Max. (Gross) 5.50kW (18,766Btu/h) 5.4kW (18,425Btu/h)
Input - Min. (Gross) 2.3kW (7,850 Btu/h) 3.8kW (12,965Btu/h)
Inlet Test Pressure (Cold) 20.0 ± 1.0mbar (8.0 ± 0.4in
w.g.)
37.0 ± 1.0 mbar (14.85 ±
0.4in w.g.)
Gas Connection 8mm pipe 8mm pipe
Burner Injector Cat 82 - 065 Size 116
Pilot Copreci Ref. O.D.S
21500/212
Copreci Ref. O.D.S
21500/212 Fitted with RBM
180 -02 injector
Ignition Piezo Electric. Integral with
Gas Tap
Piezo Electric. Integral with
Gas Tap
Aeration See section 7.1 Non-adjustable

This product uses fuel effect pieces containing Refractory Ceramic Fibres
(RCF), which are man-made vitreous silicate fibres. Excessive exposure to
these materials may cause irritation to eyes, skin and respiratory tract.
Consequently, it is important to take care when handling these articles to
ensure that the release of dust is kept to a minimum. To ensure that the release
of fibres from these RCF articles is kept to a minimum, during installation and
servicing we recommend that you use a HEPA filtered vacuum to remove any
dust and soot accumulated in and around the stove before and after working on
the stove. When replacing these articles we recommend that the replaced items
are not broken up, but are sealed within a heavy duty polythene bag, clearly
labelled as RCF waste. RCF waste is classed as a stable, non-reactive
hazardous waste and may be disposed at a landfill licensed to accept such
waste. Protective clothing is not required when handling these articles, but we
recommend you follow the normal hygiene rules of not smoking, eating or
drinking in the work area and always wash your hands before eating or
drinking. This appliance does not contain any component manufactured from
asbestos or asbestos related products.
3. UNPACKING
Before installation, check that the following components, where required, have been
delivered.
Box 1 - Containg the following loose parts:
4 feet.
1 Lower casting cover.
4 securing bolts (For feet / lower casting cover).
4 flat washers (For feet / lower casting cover).
4 locking washers (For feet / lower casting cover).
2 wall plugs (For securing feet to floor).
2 wood screws (For securing feet to floor).
1 Small nut and bolt (For vent switch).
2 bolts with washers (For the diverter box).
3 self tapping screws (For burner).
1 Flue spigot.
1 Flue restrictor.
2 small machine screws (For flue spigot and flue restrictor).
Box 2 - Ceramic fuel effect.
Page 5
INSTALLER GUIDE
© Baxi Heating U.K. Limited 2007.

Stove body
The stove is supplied with a locked door. Using a suitable sized spanner, turn the
locking bolt on the front of the door in a counter clockwise direction. Carefully remove
and unpack the contents of the stove.
The stove body contains the following:
1 Burner module.
1 Inlet ‘T’ connector with nut and olive.
1 Vent switch and mounting bracket assembly.
1 Diverter box.
1 Down draught diverter.
1 Control knob assembly.
4. STOVE SET UP
Legs and lower casting cover.
(See figure 1).
1. Locate the four legs to the underside of
the casting body. There are two feet with
holes in the base. We recommend that
these be placed at the rear of the stove.
2. Place the front cover casting on top of
the front legs.
3. Secure the legs and front cover casting
to the underside of the casting body using
the bolts and washers supplied.The bolts
should have the locking washer added first
followed by the flat washer.
4. This appliance is supplied with a flue
restrictor for use where the flue draught is
excessive. Fit the restrictor as in point 1
below. There may however, be certain
circumstances where fitting the restrictor
causes the fire to fail the spillage test. In
such cases the restrictor will have to be
removed. After removal conduct the
spillage check again.
Page 6
INSTALLER GUIDE
© Baxi Heating U.K. Limited 2007.
Figure 1.

Flue collar, down draught diverter, diverter box, flue spigot and flue restrictor
plate.
These should be assembled to the stove as in figure 2. The flue spigot is screwed to
the cast collar and clamps the flue restrictor plate in place (See figure 2).
5. The down draught diverter is secured in place using the front bolt and nut that
secure the cast collar to the outside of the cast body. Unscrew and remove the nut
and washer from inside the top of the casting body. Position the down draught
diverter as in figure 3. It MUST be sealed against the top of the stove casting. It is
important that it sits on top and between the raised cast areas on the rear of the stove
body (See figure 3). Secure in
place using the nut and washer
removed previously.
Page 7
INSTALLER GUIDE
© Baxi Heating U.K. Limited 2007.
Figure 3.
Figure 2.

6.
The Thermal Switch should be fitted to the inside of the Diverter Box as in figure 4.
Secure using the nut and bolt supplied. Never modify the fixing bracket and always
ensure that the switch is fitted correctly. NEVER USE THE STOVE IF THE THERMAL
SAFETY SWITCH HAS BEEN REMOVED OR IF IT IS DAMAGED IN ANY WAY.
7. Locate the diveter box to the rear of the
stove body and secure in place using the
bolts and washers supplied.
8. Offer the burner module into the stove
and connect the thermal switch leads to the
tags mid way along the thermocouple.
9. Locate the burner assembly inside the
stove body as in figure 5 (The outer front of
the stove is not shown for clarity). The rear
leg of the burner should sit on the rear of
the casting. Secure using the three screws
supplied The screw locations are shown ion
figure 5).
10. Secure the control knob assembly to the
gas valve, the screw tail should secure onto
the flat on the gas valve spindle.
Page 8
INSTALLER GUIDE
© Baxi Heating U.K. Limited 2007.
Figure 5.
Figure 4.

5. GENERAL INSTALLATION REQUIREMENTS
The installation must be in accordance with these instructions.
For the user’s protection, in the United Kingdom it is the law that all gas appliances
are installed by competent persons in accordance with the current edition of the Gas
Safety (Installation and Use) Regulations. Failure to install the appliance correctly
could lead to prosecution. CORGI requires its members to work to recognised
standards.
In the United Kingdom the installation must also be in accordance with all the relevant
parts of local regulations.
BS 5440 Part 1
BS 5440 Part 2
BS 4543 Part 2
BS 5871 Part 1
BS 6891
BS 8303
In England and Wales, the current edition of the Building Regulations issued by the
Department of the Environment and the Welsh Office
In Scotland, the current edition of the Building Standards (Scotland) Regulations
issued by the Scottish Executive.
In Northern Ireland, the current edition of the Building regulations (Northern Ireland)
issued by the Department of the Environment for Northern Ireland.
In the republic of Ireland the installation must be carried out by a competent person
and also conform to the relevant parts of:
a) The current edition of IS 813 “Domestic Gas Installations”
b) All relevant national and local rules in force.
Where no specific instructions are given, reference should be made to the relevant
British Standard Code of Practice.
The Hearth.
!
The appliance must be mounted on a non-combustible hearth (N.B. conglomerate
marble hearths are considered as non-combustible). The hearth material must be at
least 12mm thick. The hearth must protrude at least 150mm (6”) in front of the stove
body. In most buildings with solid concrete floors this requirement will be met by the
floor itself.
Page 9
INSTALLER GUIDE
© Baxi Heating U.K. Limited 2007.

© Baxi Heating U.K. Limited 2007.
INSTALLER GUIDE
Page 10
Clearances
Clearances from combustible and non-combustible materials must be at least those
shown in figure 6.
Flue / Chimney.
! The stove is approved for use with 102mm (4
inch) diameter insulated Selkirk
insta - lock gas vent.
! The spigot is designed to be compatible with a
selkirk 4 SIL - DH draft hood connector. The inner
sleeve will require reducing in length so that it
prodrudes 25mm below the outer sleeve (See figure
7).
! Before you install the stove make sure the
chimney flue outlet is correctly positioned to align
with the flue outlet on the stove and that the
chimney is in good condition. If not, a chimney liner
must be installed or a suitable class 2 gas flue
used. A draught is necessary to ensure the products of combustion are fully
evacuated. Connect and seal the the stove flue collar to the chimney using full depth
of collar. The flue must have a minimum effective height of 3 metres (10ft), however
to, to ensure optimum performance we recommend 3.66 metres (12ft) or higher. The
flue must be free of obstruction and any dampers must be fixed in a permanently
open position. Ensure that the chimney is not closed and that it has been swept prior
Figure 6. Dimensions and Clearances
Figure 7.
Inhaltsverzeichnis
Andere Baxi Herd Handbücher
Beliebte Herd Handbücher anderer Marken

Vermont Castings
Vermont Castings Intrepid 2 Bedienungsanleitung

Italiana Camini
Italiana Camini CLASSICA Kurzanleitung

Avalon
Avalon Vashon Avanti DVS FS Bedienungsanleitung

Spartherm
Spartherm ambiente a1 Bedienungsanleitung

Dimplex
Dimplex MCFSTV12AU Bedienungsanleitung

Warmlite
Warmlite WL46040 Bedienungsanleitung