Beckhoff CX1100-09 Series Bedienerhandbuch

Hardware Documentation
CX1100-09xx
UPS for Embedded PCs CX10x0
1.4
2015-07-02
Version:
Date:


Table of contents
Table of contents
1 Foreword ....................................................................................................................................................4
1.1 Notes on the documentation............................................................................................................. 4
1.2 Safety instructions ............................................................................................................................ 5
1.3 Documentation Issue Status............................................................................................................. 5
2 Product overview.......................................................................................................................................7
2.1 Appropriate Use................................................................................................................................ 7
2.2 System overview............................................................................................................................... 7
2.3 Technical Data CX1100-0900, CX1100-0910, CX1100-0920, CX1100-0930 .................................. 9
2.4 CX1100-09xx Connections ............................................................................................................. 10
2.5 Technical data CX1100-0900, CX1100-0910, CX1000-0920, CX1100-0930................................. 12
3 Transport..................................................................................................................................................13
3.1 Unpacking, installation and transport.............................................................................................. 13
4 Fitting and wiring.....................................................................................................................................14
4.1 Mechanical assembly ..................................................................................................................... 14
4.1.1 Dimensions .........................................................................................................................14
4.1.2 Mechanical installation of the UPS Module.........................................................................16
5 Commissioning........................................................................................................................................19
5.1 Charging time ................................................................................................................................. 19
5.2 Discharging time ............................................................................................................................. 20
5.3 Setting retention time...................................................................................................................... 25
5.4 Register settings CX1100-09xx ...................................................................................................... 26
5.5 Settings in the System Manager..................................................................................................... 27
5.6 Controlling theUPS from the PLC ................................................................................................... 31
6 Error handling and diagnostics .............................................................................................................36
6.1 LEDs CX1100-09xx ........................................................................................................................ 36
7 Decomissioning.......................................................................................................................................37
7.1 Removal and disposal .................................................................................................................... 37
8 Appendix ..................................................................................................................................................39
8.1 Certifications ................................................................................................................................... 39
8.2 Support and Service ....................................................................................................................... 40
CX1100-09xx 3
Version: 1.4

Foreword
1 Foreword
1.1 Notes on the documentation
This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.
It is essential that the following notes and explanations are followed when installing and commissioning
these components.
The responsible staff must ensure that the application or use of the products described satisfy all the
requirements for safety, including all the relevant laws, regulations, guidelines and standards.
Disclaimer
The documentation has been prepared with care. The products described are, however, constantly under
development.
For that reason the documentation is not in every case checked for consistency with performance data,
standards or other characteristics.
In the event that it contains technical or editorial errors, we retain the right to make alterations at any time
and without warning.
No claims for the modification of products that have already been supplied may be made on the basis of the
data, diagrams and descriptions in this documentation.
Trademarks
Beckhoff®, TwinCAT®, EtherCAT®, Safety over EtherCAT®, TwinSAFE®, XFC®and XTS® are registered
trademarks of and licensed by Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.
Patent Pending
The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents:
EP1590927, EP1789857, DE102004044764, DE102007017835
with corresponding applications or registrations in various other countries.
The TwinCAT Technology is covered, including but not limited to the following patent applications and
patents:
EP0851348, US6167425 with corresponding applications or registrations in various other countries.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH,
Germany
Copyright
© Beckhoff Automation GmbH & Co. KG, Germany.
The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization are prohibited.
Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a
patent, utility model or design.
CX1100-09xx4 Version: 1.4

Foreword
1.2 Safety instructions
Safety regulations
Please note the following safety instructions and explanations!
Product-specific safety instructions can be found on following pages or in the areas mounting, wiring,
commissioning etc.
Exclusion of liability
All the components are supplied in particular hardware and software configurations appropriate for the
application. Modifications to hardware or software configurations other than those described in the
documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG.
Personnel qualification
This description is only intended for trained specialists in control, automation and drive engineering who are
familiar with the applicable national standards.
Description of symbols
In this documentation the following symbols are used with an accompanying safety instruction or note. The
safety instructions must be read carefully and followed without fail!
DANGER
Serious risk of injury!
Failure to follow the safety instructions associated with this symbol directly endangers the
life and health of persons.
WARNING
Risk of injury!
Failure to follow the safety instructions associated with this symbol endangers the life and
health of persons.
CAUTION
Personal injuries!
Failure to follow the safety instructions associated with this symbol can lead to injuries to
persons.
Attention
Damage to the environment or devices
Failure to follow the instructions associated with this symbol can lead to damage to the en-
vironment or equipment.
Note
Tip or pointer
This symbol indicates information that contributes to better understanding.
1.3 Documentation Issue Status
Version Changes
1.4 new UPS CX1100-0930 added
1.3 usage with CX systems added
CX1100-09xx 5
Version: 1.4

Foreword
Version Changes
1.2 technical data for charge corrected
1.1 annotations to usage of CX1100-0900 and CX1020
1.0 released version
0.4 revision of discharge graphs, licenses added
0.3 resorting / small corrections
0.2 revised version
0.1 preliminarily version
CX1100-09xx6 Version: 1.4

Product overview
2 Product overview
2.1 Appropriate Use
The CX10x0 device series is a modular control system designed for top-hat rail installation. The system is
scalable, so that the required modules can be assembled and installed in the control cabinet or terminal box
as required.
The UPS Modules are designed to supply CX10x0 Embedded PCs and their bus terminals.
2.2 System overview
UPS module is available in four variations:
• CX1100-0900
• CX1100-0910
• CX1100-0920
• CX1100-0930
The UPS module is used for the uninterruptible power supply of CX CPUs and any connected CX
components. In the event of a failure of the external supply, the module ensures that the application software
can save important data, e. g. on a Compact Flash card, NOVRAM or in a database via the network. During
the UPS retention time, the machine or process can be transferred into a defined state, and the operating
system can be shut down. The retention time can be set via a rotary switch or via software.
The use of state of the art capacitors makes this UPS module – unlike other battery powered techniques –
absolutely maintenance-free and offers rapid charging. The module can simply added to a CX system. Only
a 24 V DC supply cable is needed. The 24 V DC output voltage of the UPS is protected against short circuit
and overload. The CX1100-09xx may be retrofitted on site. A DPRAM user interface provides options for
settings and UPS status messages.
The functionality of the UPS is therefore independent of the operating system to be used. No driver software
is required. The TwinCAT System Manager recognizes the UPS module automatically, and the UPS signals
are available to the PLC programmer. A controlled 24 V DC power supply unit with a minimum output current
of 4 A is required.
CX1100-09xx 7
Version: 1.4

Product overview
2.3 Technical Data CX1100-0900, CX1100-0910,
CX1100-0920, CX1100-0930
The UPS-Modules are available in four versions. The user can choose the fitting version for his purpose. The
table shows differences and common properties:
Technical data CX1100-0900 CX1100-0910 CX1100-0920 CX1100-0930
Power supply 24 V DC (-15 %/+20 %)
Storage technology capacitive
Charge 20 As 20 As 40 As 40 As
Retention time adjustable, load-dependent
Output current
max.
550 mA (24 V DC) 1.1 A (24 V DC) 1.1 A (24 V DC) 2.0 A (24 V DC)
Charging current max. 4 A
Diagnostics LED 24 V DC-Input, 24 V DC-Output, CHARGE
System bus 16 Bit ISA (PC104 standard)
Max. power
consumption
2 W
Dimensions (W x H
x D)
57 mm x 100 mm x
91 mm
76 mm x 100 mm x
91 mm
95 mm x 100mm x
91 mm
95 mm x 100mm x
91 mm
weight app. 345 g app. 465 g app. 617 g app. 650 g
Operating
temperature
0 °C ... +55 °C
Storage
temperature
-25 °C ... +85 °C
Relative humidity 95% no condensation
Vibration/Shock
resistance
conforms to EN 60068-2-6 / EN 60068-2-27/29
EMC resistance
burst / ESD
conforms to EN 61000-6-2 / EN 61000-6-4
protection class IP 20
Note
The maximal output current for UPS module CX1100-0900 is 550 mA! For higher output
current make use of the UPS modules (CX1100-0910 / CX1100-0920), with bigger output
current.
The maximal output current is not suitable for the CX1020 Embedded PCs. So it is strongly
recommended to make use of the UPS modules (CX1100-0910 / CX1100-0920), with big-
ger output current.
CX1100-09xx 9
Version: 1.4

Product overview
2.4 CX1100-09xx Connections
The UPS-Modules are supplied with power by 5-pin "Open Pluggable Connector". The other components of
the embedded system are supplied via the PC 104 bus with 24V DC. (-15 % to +20 % tolerance)
Table1: Pin assignment "Open Pluggable Connector":
Pin Assignment
50 V DC OUT ( UPS output current)
424 V DC OUT ( UPS output current)
3PWR FAIL (digital output)
20 V DC IN (UPS incoming power supply)
124 V DC IN (UPS incoming power supply)
Connection to power supply
For power supply units with K-bus / E-bus connection (CX1100-0002, CX1100-0003 und CX1100-004) the
supply is realized as follows:
Though the power supply CX1100-0001 has no terminal bus interface the module is connected to the upper
input connectors (24V). Older versions of the power supply are labeled with UPS -/+. These input are not
used and more and must not be connected. The figure shows the correct connection.
CX1100-09xx10 Version: 1.4
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere Beckhoff UPS Handbücher
Beliebte UPS Handbücher anderer Marken

Pylontech
Pylontech Victron & Pylontech US5000 Bedienungsanleitung

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Bedienungsanleitung

Mecer
Mecer ME-1000-WTU Bedienungsanleitung

Mustek
Mustek PowerMust 530(B) Plus Installations- und Betriebshandbuch

Emerson
Emerson Liebert NXL series Bedienungsanleitung

MAKELSAN
MAKELSAN BOXER SERIES Bedienungsanleitung