Foreword
Installation manual for T7BR
Foreword
All operator panels are developed to satisfy the demands of human-machine
communication. Built-in functions such as displaying and controlling text,
dynamic indication, time channels, alarm and recipe handling are included.
The operator panel works primarily in an object-oriented way, making it easy to
understand and use. Configuration is carried out on a PC using the iX Developer.
Theprojectcanthenbetransferredandstoredintheoperatorpanelitself.
Various types of automation equipment such as PLCs, servos or drives can be
connected to the operator panels. In this manual, the term “the controller” refers
to the connected equipment.
This manual explains how to install the operator panel. Please refer to the
iX Developer reference manual for further information.
Order no: MAEN185
Copyright © 2015-02 Beijer Electronics AB. All rights reserved.
The information in this document is subject to changewithoutnoticeandisprovidedasavailableatthe
time of printing. Beijer Electronics AB, including all its group companies, reserves the right to change any
information without updating this publication. Beijer Electronics AB, including all its group companies,
assumesnoresponsibilityforanyerrorsthatmayappearinthisdocument. Readtheentireinstallation
manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair
this equipment. Beijer Electronics AB, including all its group companies, are not responsible for modified,
altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire
the appropriate knowledge to use the equipment properly in their specific applications. Persons responsible
for the application and the equipment must themselves ensure that each application is in compliance with
all relevant requirements, standards and legislationinrespecttoconfigurationandsafety. Onlypartsand
accessories manufactured according to specifications set by Beijer Electronics AB, including all its group
companies, may be used.
BEIJER ELECTRONICS AB, INCLUDING ALL ITS GROUP
COMPANIES, SHALL NOT BE LIABLE TO ANYONE FOR ANY
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING FROM THE INSTALLATION, USE OR
REPAIR OF THIS EQUIPMENT, WHETHER ARISING IN TORT,
CONTRACT, OR OTHERWISE. BUYER'S SOLE REMEDY SHALL
BE THE REPAIR, REPLACEMENT, OR REFUND OF PURCHASE
PRICE, AND THE CHOICE OF THE APPLICABLE REMEDY SHALL
BE AT THE SOLE DISCRETION OF BEIJER ELECTRONICS AB,
INCLUDING ALL ITS GROUP COMPANIES.
Beijer Electronics, MAEN185

Contents
Contents
1 SafetyPrecautions ....................................................... 4
1.1 General ........................................................... 4
1.2 UL, cUL, ATEX, and IECEx Installation ...................... 4
1.3 High Potential Testing ........................................... 6
1.4 DuringInstallation .............................................. 6
1.5 DuringUse ....................................................... 6
1.6 Service and Maintenance ........................................ 6
1.7 Dismantling and Scrapping ..................................... 7
2 Installation ............................................................... 8
2.1 SpaceRequirements ............................................. 8
2.2 InstallationProcess .............................................. 9
2.2.1 ConnectionstotheController ..................................11
2.2.2 HazardousLocationInstallation ................................12
2.2.3 OtherConnectionsandPeripherals .............................12
3 TechnicalData ........................................................... 13
4 ChemicalResistance .................................................... 15
4.1 MetalCasing ..................................................... 15
4.2 Touch Screen and Overlay Material ............................ 16
4.2.1 AutoflexEB ......................................................16
4.2.2 TouchScreenSurface ............................................17
4.2.3 TouchScreenProtector ..........................................17
4.3 Terminal to Panel Gasket ........................................ 18
5 OperatorPanelDrawings .............................................. 19
5.1 Connectors ....................................................... 19
5.2 CommunicationPorts ........................................... 19
5.3 T7BROutline ................................................... 20
6 Additional Installation Tips ............................................ 21
6.1 Grounding the operator panel .................................. 21
6.2 EthernetConnectionintheOperatorPanel ................... 22
6.3 To Achieve Better EMC Protection ............................. 24
6.4 AmbientTemperature ........................................... 25
6.5 Safety ............................................................. 26
6.6 GalvanicIsolation ................................................ 27
6.7 Cable and Bus Termination RS485 ............................. 28
6.8 COM Port Common-Mode Voltage ........................... 28
Beijer Electronics, MAEN185

Safety Precautions
1SafetyPrecautions
Both the installer and the owner and/or operator of the operator panel must read
and understand this installation manual.
1.1 General
•Read the safety precautions carefully.
•Check the delivery for transportation damage. If damage is found, notify the
supplier as soon as possible.
•The supplier is not responsible for modified, altered or reconstructed
equipment.
•Use only parts and accessories manufactured according to specifications of
the supplier.
•Read the installation and operating instructions carefully before installing,
using or repairing the operator panel.
•Neverallowfluids,metalfilingsorwiringdebristoenteranyopeningsinthe
operator panel. This may cause fire or electrical shock.
•Only qualified personnel may operate the operator panel.
•Storing the operator panel where the temperature is lower/higher than
recommended in this manual can cause the LCD display liquid to
congeal/become isotopic.
•The LCD display liquid contains a powerful irritant. In case of skin contact,
wash immediately with plenty of water. In case of eye contact, hold the eye
open,flushwithplentyofwaterandgetmedicalattention.
•Thefiguresinthismanualservesanillustrativepurpose. Becauseofthemany
variables associated with any particular installation, the supplier cannot
assume responsibility for actual use based on the figures.
•The supplier neither guarantees that the operator panel is suitable for your
particular application, nor assumes responsibility for your product design,
installation or operation.
•It is recommended to turn on and shut down the operator panel at least once
before installing any components/cards or before connecting the operator
panel to external devices, like for example serial devices.
•This operator panel is certified to operate in a Class I, Division 2, Group A, B,
C and D hazardous environment. The operator panel must be installed and
operated as described in this document to meet this certification.
•Observe precautions for handling electrostatic discharge sensitive devices.
1.2 UL, cUL, ATEX, and IECEx
Installation
•This equipment is suitable for use in Class 2 non-hazardous locations only.
[Combinations of equipment in your system are subject to investigation by
the local authority having jurisdiction at the time of installation].
•All devices have to be supplied by a Class 2 power supply.
Beijer Electronics, MAEN185 4

Safety Precautions
Warning:
Do not disconnect equipment unless power has been removed or the area is
known to be non-hazardous
AVANT DE DECONNECTER L’EQUIPEMENT, COUPER LE COURANT
OUS’ASSURER QUE L‘EMPLACEMENT EST DESIGNE NON DANGEREUX.
Warning:
Battery may explode if mistreated. Do not recharge, disassemble or dispose
of in fire.
This product contains a BR2330A battery that is not user replaceable.
LA BATTERIE PEUT EXPLOSER EN CAS DE MAUVAISE MANIPULATION.
NE LA RECHARGEZ PAS, NE LA DÉMONTEZ PAS ET NE LA JETEZ
PAS DANS LE FEU.
CEPRODUITCONTIENTUNEPILEBR2330AQUINEPEUTPASÊTRE
REMPLACÉE PAR L'UTILISATEUR.
•Use minimum 75°C copper conductors only.
•To make wiring connections to the power supply connector, follow the table
with cable and torque specifications below:
Terminal Block Connector Wire Size TQ Lb.In.
Phoenix Contact Part No. 1757022 14–20 AWG
(2.08–0.52 mm2)
5–7
Warning:
Donotopenwhenanexplosiveatmosphereispresent.
N'OUVREZ PAS SI UNE ATMOSPHÈRE EXPLOSIVE EST PRÉSENTE.
Warning:
Explosion hazard! Do not disconnect while circuit is live unless the area is
known to be non hazardous.
RISQUE D'EXPLOSION ! NE DÉBRANCHEZ PAS LORSQUE LE CIRCUIT EST
SOUS TENSION SAUF SI LA ZONE EST CONNUE POUR ÊTRE
NON DANGEREUSE.
Caution:
This equipment is tested as a component and is to be installed inside an enclosure
rated IP54 minimum if used in an ATEX/IECEx Zone 2 area. However, since the unit is
IP66 rated it can be deployed in an IP66 ATEX/IECEx Zone 2 area if enclosed in an IP66
rated enclosure.
CET ÉQUIPEMENT EST TESTÉ EN TANT QUE COMPOSANT ET DOIT ÊTRE
INSTALLÉ DANS UN BOÎTIER AVEC INDICE DE PROTECTION IP66 MINIMUM.
Caution:
Temperature code T4 IEC/EN 60079-0 (2012) and IEC/EN 60079-15 (2010).
CODES DE TEMPÉRATURE T4 IEC/EN 60079-0 (2012) ETIEC/EN 60079-15 (2010).
Beijer Electronics, MAEN185 5

Safety Precautions
1.3 High Potential Testing
Each terminal is high-pot (high potential) tested prior to shipment. After high-pot
testing, surge arresting devices that enhance surge robustness are installed into the
terminal. After placement, these devices cause the terminal to fail the high-pot
testing.
Note:
If in-field high-pot testing is required contact Beijer Electronics.
1.4 During Installation
•The operator panel is designed for stationary installation on a planar surface,
where the following conditions are fulfilled:
–no high explosive risks
–no strong magnetic fields
–no direct sunlight
–no large, sudden temperature changes
•Install the operator panel according to the accompanying installation
instructions.
•Ground the operator panel according to the accompanyinginstallation
instructions.
•Only qualified personnel may install the operator panel.
•Separate the high voltage, signal and supply cables.
•Make sure that the voltage and polarity of the power source is correct before
connecting the operator panel to the power outlet.
•Peripheral equipment must be appropriatefortheapplicationandlocation.
1.5 During Use
•Keep the operator panel clean.
•Emergency stop and other safety functions may not be controlled from the
operator panel.
•Do not use excessive force or sharp objects when operating the touch screen.
1.6 Service and Maintenance
•Only qualified personnel should carry out repairs.
•The agreed warranty applies.
•Before carrying out any cleaning or maintenance operations, disconnect the
equipment from the electrical supply.
•Clean the display and surrounding front cover with a soft cloth and mild
detergent.
•The battery must be replaced by an authorized Beijer Electronics service
center.
Beijer Electronics, MAEN185 6

Safety Precautions
1.7 Dismantling and Scrapping
•The operator panel or parts thereof shall be recycled according to local
regulations.
•The following components contain substances that might be hazardous
to health and the environment: lithium battery, electrolytic capacitor and
display.
Beijer Electronics, MAEN185 7

Installation
2Installation
2.1 Space Requirements
•Maximum installation plate thickness: 7 mm
•Space requirements in millimeters when installing the operator panel:
100
204
100
100
50
143 50
[mm]
Note:
The dimensions on the drawing are not proportional.
Beijer Electronics, MAEN185 8

Installation
2.2 Installation Process
A Thumb Screw Installation Tool (provided) or a slotted screwdriver is required
for installation.
1. Unpack and check the delivery. If damage is found, notify the supplier.
Note:
Place the operator panel on a stable surface during installation.
Dropping the operator panel or letting it fall may cause damage.
2. To cut a correct opening for the operator panel, use the cut out dimensions
in the outline drawing. A separate cut out drawing is available for download
from the Beijer Electronics web site. For more information, see sections
Operator Panel Drawings and Technical Data.
3. Install the operator panel into the cutout with the terminal mounting ring on
the inside of the mounting panel with the connector bracket mounting holes
at the bottom and on the right side.
4. To secure the operator panel in position, insert the mounting blocks into the
openings on the side of operator panel, slide the blocks into position, and
tighten the thumbscrew. Tighten the screws (4) to 0.7 Nm ± 0.2 Nm.
Beijer Electronics, MAEN185 9

Installation
5. For most applications, the provided Thumb Screw Installation Tool provides
adequate torque. In cases where the front panel seal (IP54 or greater,
NEMA-4X) is critical, a torque wrench should be used to ensure all four
screws are torqued within the specification above.
Thumb Screw Installation Tool
6. Connect the cables in the specified order, according to the drawing and steps
below.
Caution:
•The operator panel must be brought to ambient temperature before it is started
up. If condensation forms, ensure that the operator panel is dry before connecting
it to the power outlet.
•Ensure that the operator panel and the controller system have the same electrical
grounding (reference voltage level), otherwise errors in communication may
occur.
•Ensure that the voltage and polarity of the power source is correct.
•Separate high voltage cables from signal and supply cables.
•Shielded communication cables are recommended.
24V DC
RS232/
RS422/
RS485 24V DC
A
D
Controller
Power
B
Ethernet
C
–Use 14–20 AWG (2.08–0.52 mm2)wireforthepowerconnections.
–Connect cable A.
–Connect cable B, using the provided M5 steel screw with zinc plating
and a grounding conductor (as short as possible), that is sized correctly
according to local electrical codes.
–Connect cable C.
–Connect cable D.
Beijer Electronics, MAEN185 10
Inhaltsverzeichnis
Andere BeiJer Touchscreen Handbücher

BeiJer
BeiJer iX T15C-C23 Bedienungsanleitung

BeiJer
BeiJer EPC 190 Nautic Bedienungsanleitung

BeiJer
BeiJer H-T40m Series Bedienungsanleitung

BeiJer
BeiJer X2 base 7 Bedienungsanleitung

BeiJer
BeiJer T15C Bedienungsanleitung

BeiJer
BeiJer H-T60 Series Bedienungsanleitung

BeiJer
BeiJer H-T40m Series Bedienungsanleitung
Beliebte Touchscreen Handbücher anderer Marken

IBASE Technology
IBASE Technology ASTUT-152-RE1S Bedienungsanleitung

YASKAWA
YASKAWA TP 610C Bedienungsanleitung

B&R
B&R Power Panel C Series Bedienungsanleitung

Beijer Electronics
Beijer Electronics X2 control Bedienungsanleitung

AXIOMTEK
AXIOMTEK GOT321W-521 Bedienungsanleitung

TRIDONIC.ATCO
TRIDONIC.ATCO x-touchBOX Bedienungsanleitung