Belair 100SN Bedienungsanleitung

BelAir100SN
Page 1 of 75
Release: 11.0
Document Date: May 18, 2010
Document Number: BDTK11001-A01
Document Status: Preliminary
Security Status: Confidential
Customer Support: 613-254-7070
1-877-BelAir1 (235-2471)
techsupport@belairnetworks.com
© Copyright 2010 by BelAir Networks.
The information contained in this document is confidential and proprietary to BelAir Networks. Errors and Omissions Excepted.
Specification may be subject to change. All trademarks are the property of their respective owners.
Protected by U.S. Patents: 7,171,223, 7,164,667, 7,154,356, 7,030,712 and D501,195. Patents pending in the U.S. and other countries.
BelAir Networks, the BelAir Logo, BelAir200, BelAir100, BelAir100S, BelAir100C, BelAir100T, BelAir20, BelAir100i, BelAir100SN, BelAir100N, BelView and BelView
NMS are trademarks of BelAir Networks Inc.
BelAir100SN
Installation Guide
PRODUCT MODEL: BelAir100S

May 18, 2010 Confidential Page 2 of 75
Document Number BDTK11001-A01 Preliminary
BelAir100SN Installation Guide Contents
Contents
About This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
BelAir100SN Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Infrastructure Requirements for the BelAir100SN . . . . . . . . . . . . . 6
Mounting Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Before You Install the BelAir100SN. . . . . . . . . . . . . . . . . . . . . . . . 21
Strand mounting the BelAir100SN with Omni-directional Antennas
29
Strand mounting the BelAir100SN with Directional Antennas. . . 36
Pedestal Installation of the BelAir100SN . . . . . . . . . . . . . . . . . . . . 42
Commissioning BelAir100SN Units . . . . . . . . . . . . . . . . . . . . . . . . 53
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
For More Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Conformity and Regulatory Statements. . . . . . . . . . . . . . . . . . . . . 61
Detailed Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

BelAir100SN Installation Guide About This Document
May 18, 2010 Confidential Page 3 of 75
Document Number BDTK11001-A01 Preliminary
About This Document
This guide provides the information you need to physically install the
BelAir100SN™.
Typo graph ica l
Conventions
This document uses the following typographical conventions:
• Text in < > indicates a parameter required as input for a CLI command;
for example, < IP address >
• Text in [ ] indicates optional parameters for a CLI command.
• Text in { } refers to a list of possible entries with | as the separator.
• Parameters in ( ) indicate that at least one of the parameters must entered.
Related
Documentation
The following titles are BelAir reference documents:
•
BelAir100SN User Guide
•
BelAir100SN Troubleshooting Guide

BelAir100SN Installation Guide BelAir100SN Physical Description
May 18, 2010 Confidential Page 4 of 75
Document Number BDTK11001-A01 Preliminary
BelAir100SN Physical Description
This chapter provides a physical description of the BelAir100SN and its
associated hardware.
The BelAir100SN is an integrated radio product requiring only a connection to
a suitable power source.
Without antennas and strand mounting brackets, the BelAir100SN is
approximately 8.5 inches (21.6 cm) high, 15.5 inches (39.4 cm) wide and
7 inches (17.8 cm) deep. It weighs 29 lbs (13.2 kg). See Figure 1 on page 4.
Figure 1: BelAir100SN Unit without Antennas
AC Power Supply
Specifications
The BelAir100SN accepts an AC input power in the range of 40 VAC to
90 VAC -0% +10% with a quasi-square wave. The frequency range is 47 to
63 Hz. The typical current draw is less than 1 A.

BelAir100SN Installation Guide BelAir100SN Physical Description
May 18, 2010 Confidential Page 5 of 75
Document Number BDTK11001-A01 Preliminary
AC Power Source
The BelAir100SN draws its AC power from plant power through its KS
threaded power interface. The BelAir100SN includes an industry standard GRS
connector that mates with a coaxial cable terminator with a KS interface for
cables of the following sizes: 0.412, 0.500, 0.625, 0.750, 0.875 and 1.000 inches.
A KS to F-type adapter can also be used. The GRS connector provides two
points of contact for a robust AC power connection.

BelAir100SN Installation Guide Infrastructure Requirements for the BelAir100SN
May 18, 2010 Confidential Page 6 of 75
Document Number BDTK11001-A01 Preliminary
Infrastructure Requirements for the BelAir100SN
This section describes the infrastructure that is required at the location where
BelAir100SN units are installed:
•“Protective Earth Ground” on page 6
•“AC Power” on page 7
•“Lightning Protection” on page 9
•“DOCSIS” on page 9
•“Ethernet” on page 13
•“Antenna Type and Placement” on page 14
Any identified specific third party parts are recommendations or examples only.
Substitution of equivalent parts is permitted. (If you are unsure of the
equivalency of a certain component, contact BelAir Networks.)
Protective Earth
Ground
For safety and functional operation, each BelAir unit must be connected to a
reliable earth ground before electrical power is applied to it. Special attention
should be made when installing the ground and connection of the ground wire
must follow local and national wiring codes. If multiple BelAir units are installed
at a single location, then each BelAir unit must be connected to the same
ground point.
The BelAir100SN is powered by the coaxial cable and is considered grounded
where connected to the cable shield, as required by US National Electric Code,
section 820-41. In addition, installers may wish to bond the BelAir100SN
ground to the messenger wire. To do so, the additional connection is to a
1/4 inch (approx. 6 mm) ground terminal with screw. Figure 2 shows the
location of the ground point and the ground terminal. Installers should follow
normal practices when grounding the unit. Installers should verify that all
grounding requirements listed in this document have been met.
Warning — Protective Earth Ground
Failure to connect the protective earth ground can result in a
shock hazard.

BelAir100SN Installation Guide Infrastructure Requirements for the BelAir100SN
May 18, 2010 Confidential Page 7 of 75
Document Number BDTK11001-A01 Preliminary
Figure 2: BelAir100SN Ground Point
AC Power The BelAir100SN accepts power in the range of 40 VAC to 90 VAC (-0% to
+10%) from a quasi-square wave cable UPS power supply. The BelAir100SN
also requires that the cable UPS power supply limits its output current to 30 A.
Installers must ensure that the supplied power meets these requirements.
The BelAir100SN contains a permanently attached female KS threaded power
interface (Corning Gilbert part number G-EXT-1.5-SC-T). This connector can
connect with an industry standard GRS KS male threaded connector to accept
cables of the following sizes: 0.412, 0.500, 0.625, 0.750, 0.875 and 1.000 inches.
The mating connector accepts 0.065-inch to 0.75-inch pins trimmed to
0.5 inches. Figure 3 shows the female KS connector.
Ground point
through cable
connector and shield
Ground terminal
through 1/4 inch
screw

BelAir100SN Installation Guide Infrastructure Requirements for the BelAir100SN
May 18, 2010 Confidential Page 8 of 75
Document Number BDTK11001-A01 Preliminary
Figure 3: KS Connector
A KS to F-type adapter can also be used. See Figure 4. The customer is
responsible for supplying the appropriate coaxial cable terminator with a KS
male interface or the equivalent KS to F-type adapter. BelAir Networks
recommends using Corning Gilbert part number GF-625-CH-S-T which is
designed to work well with the BelAir100SN female KS threaded power
interface.
Figure 4: KS to F-type Adapter
BelAir100SN

BelAir100SN Installation Guide Infrastructure Requirements for the BelAir100SN
May 18, 2010 Confidential Page 9 of 75
Document Number BDTK11001-A01 Preliminary
Professional installers with appropriate credentials and experience are
responsible for installing coaxial cable terminator or the KS to F-type adapter
onto the cable power supply using industry and corporate standard procedures.
Lightning
Protection
BelAir units are not designed to survive a direct lightning hit. However, they are
intended to withstand the voltage and current surges induced from nearby
lightning activity.
The BelAir100SN is designed to sustain multiple 6 kV/3 kA lightning surges
without damage or loss of operation. The BelAir100SN does not require
lightning protection except when an external antenna is installed more than
3 feet (approx. 1 m) from the unit.
In this case, you must use lightning arrestors to protect the external antennas
ports. When lightning arrestors are used, they should be located within 3 feet
(approx. 1 m) of the BelAir100SN unit and must be grounded to both the unit
and protective earth ground. The N-type connector may be used to complete
the ground connection.
DOCSIS BelAir100SN units contain an embedded Hitron DOCSIS 3.0 cable modem,
model number BRG-35502, providing connectivity to a host network, such as
the Internet.
The cable modem is accessed directly through the GRS connector that is used
for both power input and as a DOCSIS RF interface. The cable modem is fully
DOCSIS 3.0 compliant and designed for use with 75 ohm cables.
The standard input range of a cable modem is -15 dBmV to +15 dBmV for
DOCSIS 3 and 17 dBmV for DOCSIS 3. The BelAir100SN implements
independent 0 to 20 dB digital attenuators in both upstream and downstream
paths.
Cable Modem Receiver Specifications
Tab l e 1 shows the cable modem receiver characteristics.
Table 1: Cable Modem Receiver Characteristics
Characteristic DOCSIS 2.0 DOCSIS 3.0
Demodulation 64/256 QAM

BelAir100SN Installation Guide Infrastructure Requirements for the BelAir100SN
May 18, 2010 Confidential Page 10 of 75
Document Number BDTK11001-A01 Preliminary
Cable Modem Transmitter Specifications
Tab l e 2 shows the cable modem transmitter characteristics.
Maximum speed • 38 Mbps (64 QAM) / 43 Mbps
(256 QAM) DOCSIS
• 5120 kbps / 10 Mbps (QPSK /
16 QAM) DOCSIS
• 41.4 Mbps (64 QAM) /
55.2 Mbps(256 QAM) EuroDOCSIS
• +171.52 (+152) Mbps with four DS
channel bounding (DOCSIS)
• +222.48 (+200) Mbps with four DS
channel bounding (EuroDOCSIS)
Frequency range • 91 to 857 MHz ±30 kHz (Center)
DOCSIS
• 108 to 862 MHz ±30 kHz (Edge)
EuroDOCSIS
• 93 to 767 MHz ±30 kHz (Center)
DOCSIS-J
• 50 MHz to 1002 MHz (DOCSIS)
Bandwidth 6 MHz (DOCSIS, DOCSIS-J)
8 MHz (EuroDOCSIS)
6/8 MHz (DOCSIS and EuroDOCSIS dual mode)
Table 1: Cable Modem Receiver Characteristics (Continued)
Characteristic DOCSIS 2.0 DOCSIS 3.0
Table 2: Cable Modem Receiver Characteristics
Characteristic DOCSIS 2.0 DOCSIS 3.0
Modulation TDMA: QPSK, 8 QAM, 16 QAM,
32 QAM, 64 QAM
S-CDMA: QPSK, 8 QAM, 16 QAM, 32
QAM, 64 QAM, 128 QAM
QPSK, 8 QAM, 16 QAM, 32 QAM,
64 QAM and 128 QAM
Maximum speed 320, 640, 1280, 2560, 5120 kbps
(QPSK)
640, 1280, 2560, 5120, 10240 kbps (16
QAM)
+122.88 (+108) Mbps with four US
channel bounding
(DOCSIS / EuroDOCSIS)
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Belair Drahtloser Zugangspunkt Handbücher
Beliebte Drahtloser Zugangspunkt Handbücher anderer Marken

D-Link
D-Link DWL-2100AP - AirPlus Xtreme G Bedienungsanleitung

Ubiquiti
Ubiquiti NanoStation NSM2 Bedienungsanleitung

Cisco
Cisco Aironet 1550 Series Bedienungsanleitung

Aruba
Aruba IAP-335 Bedienungsanleitung

Advantek Networks
Advantek Networks AWN-AP-54MR Bedienungsanleitung

IP-COM
IP-COM AP355 Bedienungsanleitung

Buffalo
Buffalo AirStation WLA-L11G Bedienungsanleitung

EnGenius
EnGenius EnStationACv2 Bedienungsanleitung

D-Link
D-Link DAP-3662 Bedienungsanleitung

xG Technology
xG Technology xMax CN1300 Bedienungsanleitung

Widelink
Widelink ezWave WAP-1100 Series Bedienungsanleitung

Edimax
Edimax CAP1200 Bedienungsanleitung