1Precautions 3
2 Introduction 4
2.1 Systems at a Glance 4
3 Unpacking and Installing the Hardware 6
4 Delivery Status 7
5 Configuration through the Web Interface 8
5.1 Configuration of the Network Settings and Access to the Interface 8
5.2 Time and Date Settings 11
5.3 Configuring the Volume 12
5.4 Creating an Initiator Group 14
5.5 Creating LUNs 14
6 Adding Storage 17
6.1 Installing a Shelf 17
7 Monitoring and Maintenance 23
7.1 Monitoring the System 23
7.2 Maintenance 24
7.3 Hardware Troubleshooting 26
7.4 Software Update 28
7.5 Disk Identification 30
8 Technical Data 31
8.1 Technical Specifications DSA-S5B50 31
8.2 Technical Specifications DSA-N2B20 32
8.3 Technical Specifications DSA-N2B50 33
8.4 Technical Specifications Disk Shelf Expansion Unit –DSX-N2X00-14AT 34
9 Trademarks 35

2en | Table of Contents DSDA iSCSI Disk Array Series
V 1 | 2008.08 Installation Guide Bosch Security Systems

DSDA iSCSI Disk Array Series Precautions | en 3
Bosch Security Systems Installation Guide V 1 | 2008.08
1 Precautions
– The system is heavy even without disks installed. At least two people are required to
install the system.
– The rack cabinet into which this system will be installed must support overcurrent
protection and must not be overloaded by the modules installed. Other requirements,
such as ventilation airflow, rack stabilizing features, electrical earth, and electrical
distribution, must comply with the technical specifications listed in Section 8 Technical
Data, page 31 and in the documentation that came with this product.
– All systems must be mounted with and supported by the rails provided and secured in
position by the four screws in the front side flanges. In no instance is a system to be
mounted by the front side flanges only as this will result in the deforming of the systems
chassis causing unacceptably high pressures and/or torques to be applied to internal
components resulting in various failure modes.
– System Integrators should ensure that any integrated storage solution that includes this
product has been tested and proved to meet government regulations and codes for
subjects including safety, fire, and electrical.
– Make sure you have a soft, clean surface to place your system before working on it.
Placing the system on a rough surface during servicing may damage the chassis finish.
– Do not remove any module or component item from its anti-static bag until you are ready
to install it. Pick up and hold modules by their edges or canister. Avoid touching PCBs
and connector pins.
– Observe all standard ESD prevention methods, e.g., wear an anti-static wristband to
prevent static electricity from damaging the electric components.
– When replacing components insert them as gently as possible while assuring full
engagement. Vibration or shock can damage hard drives in the affected unit or other
units in the rack. Hard drives are very sensitive to shock and vibration, especially while in
operation and should always be handled very carefully.
– After all equipment is installed in a rack dress the power and data cables such that power
cables are not resting against data (SCSI, IP, RS-232) cables.

4en | Introduction DSDA iSCSI Disk Array Series
V 1 | 2008.08 Installation Guide Bosch Security Systems
2 Introduction
This guide explains the installation of the digital storage systems of type
– DSA-S5B50
– DSA-N2B20
– DSA-N2B50
for either direct storage of recorded video data or for use with the VRM Video Recording
Manager application.
Additional documentation is available on the internet and can be downloaded from
www.boschsecurity.com under Product Catalog > CCTV > IP Video > Disk Arrays.
2.1 Systems at a Glance
2.1.1 Hardware Overview
Example overview (DSA-N2B20):
DSA-S5B50 DSA-N2B20 DSA-N2B50
12 / 6 disks, 1 TB each 12 disks, 750 GB each 20 disks, 750 GB each
shelf expansion units
available with 14 disks
(750 GB) each
shelf expansion units
available with 14 disks
(750 GB) each
RAID-4
RAID-DP optionally
configurable
RAID-DP RAID-DP

DSDA iSCSI Disk Array Series Introduction | en 5
Bosch Security Systems Installation Guide V 1 | 2008.08
Example front side (DSA-N2B20):
Example rear side (DSA-N2B20):
Expansion unit – disk shelf: Front side
Expansion unit – disk shelf: Rear side
2.1.2 CCTV Integration
Example for installation without VRM:

6en | Unpacking and Installing the Hardware DSDA iSCSI Disk Array Series
V 1 | 2008.08 Installation Guide Bosch Security Systems
3 Unpacking and Installing the Hardware
1. Unpack your system by opening the packing box and lifting the outer shipping box off the
pallet.
2. Install the appropriate rack mount for your installation and system using the Rack
Installation flyer in the rail kit box for reference.
3. Install the appropriate rack mount for any disk shelves that will be connected to the
system
4. With two people, lift the system into the rack or system cabinet, and secure it to the rack
uprights. The system weighs slightly over 30 kg (67 lb) and requires one person at the
end of the system to guide it into the rail ends.
5. For installation and wiring of additional disk shelves, see Section 6 Adding Storage,
page 17.
6. Connect the power cords, making sure that the power supplies are connected to
separate AC power sources. This ensures redundant power sources.
Make sure to set the power cable retention clips properly.
Ensure that power supply LEDs are lit.
i
NOTICE!
For more detailed information on the hardware installation please refer to the documentation
available on www.boschsecurity.com under Product Catalog > CCTV > IP Video > Disk
Arrays.
!
WARNING!
The storage system is heavy. Two people are required to lift a system.
!
CAUTION!
Only use the rail kit supplied with the system. Using a different rail kit can cause injury to you
or damage to your system.

DSDA iSCSI Disk Array Series Delivery Status | en 7
Bosch Security Systems Installation Guide V 1 | 2008.08
4 Delivery Status
For use with the VRM Video Recording Manager application or for direct recording from Bosch
cameras and senders, the system should be configured following the steps in the next
chapter.
Preconfigured settings upon delivery:
All further configuration is done through the Web-based user interface or VRM 1.5 or higher.
Each system is delivered with the preconfigured IP address 10.10.10.10 on Ethernet port e0a
and IP address 10.10.10.11 on the second Ethernet port e0b.
DSA-S5B50 DSA-N2B20 DSA-N2B50
RAID type RAID-4 RAID-DP RAID-DP
Volume vol0 with 2 disks vol0 with 3 disks vol0 with 3 disks
IP address 10.10.10.10 10.10.10.10 10.10.10.10
IP address (2nd port) 10.10.10.11 10.10.10.11 10.10.10.11
User (Web interface) root root root
Password <blank> <blank> <blank>

8en | Configuration through the Web Interface DSDA iSCSI Disk Array Series
V 1 | 2008.08 Installation Guide Bosch Security Systems
5 Configuration through the Web Interface
Follow these steps to configure each system. This procedure is nearly identical for all three
types of storage systems.
1. Turn on the system.
DSA-S5B50: The power button is located on the front side on the left-hand side.
DSA-N2B20 / DSA- N2B50 /additional disk shelves: There is a power switch on each
power supply unit (right- and left-hand side) on the rear side of the device.
If there are additional disk shelves installed, first power on the base unit, then power on
the expansion units.
5.1 Configuration of the Network Settings and Access to the
Interface
All systems are delivered with a default IP address configuration of 10.10.10.10, netmask
255.0.0.0. In order to connect to the system, you need to configure a network interface on
your computer to use the same network.
i
NOTICE!
Do not use the S5B50 management software StoreVault Manager for the configuration. The
DSA series come with a dedicated Bosch standardized system layout. StoreVault Manager is
not compatible with the Bosch layout.
i
NOTICE!
It can take a few seconds until the LEDs on your system power supplies light up.
i
NOTICE!
The Java Runtime Environment must be installed on your computer in order to use the Web
interface. Always use the most recent version.
Andere Handbücher für DSDA ISCSI DISK ARRAY SERIES DSA-N2B20
1
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere Bosch Disk-Array-System Handbücher
Beliebte Disk-Array-System Handbücher anderer Marken

Fujitsu
Fujitsu ETERNUS DX60 S2 Bedienungsanleitung

Accom
Accom WSD/2XTREME Bedienungsanleitung

HP
HP Compaq Presario,Presario 4400 Gebrauchsanweisung

ATTO Technology
ATTO Technology Diamond Storage Array V-Class Bedienungsanleitung

National Instruments
National Instruments RMX-8268 Bedienungsanleitung

Overland Tandberg
Overland Tandberg SnapServer DX1 Bedienungsanleitung