LB-KP8E-ICP / LB-KP16E-ICP
USER MANUAL

8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
SAFETY INSTRUCTIONS AND COMPLIANCE DECLARATION
PLEASE OBSERVE THE FOLLOWING SAFETY PRECAUTIONS
SURGE PROTECTION DEVICE RECOMMENDED
This product contains sensitive electrical components that may be damaged by
electrical spikes,surges,electric shock,lightning strikes, etc. Use of surge proctection
system is highly recommended in order to protect and extend the life of your
equipment.

8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
SAFETY INFORMATION
Do not use this device near water/liquids. This device should not be exposed to dripping and
splashing or liquids.
Clean only with dry cloth.
Do not use solvents such as paint thinners and acetone to clean external casing. Such
agents will remove any labels on the device.
Do not block any fan ventilation openings.
Do not install near any sources of intense heat such as radiation, boilers, or other equipment
that produce heat
Not intended for use/storage in close proximity of critical medical supplies such as those that
might come into direct contact with patients or medical sta.
Protect the power cord from being pinched or damaged at receptacles and the point of exit
from the device.
Only use attachment /accessories specified by manufacturer. If you have any questions
about the compatibility of an accessory, contact your dealer.
In case liquid spillage on device, unplug mains power cord and contact your dealer. Continu-
ous use in this case may result in fire or electric shock.
To reduce the risk of electric shock, do not touch connectors with wet hand.
Only power with the marked voltage on the device. Any other voltage can cause fire or elec-
tric shock.
Do not use the device if an abnormality occurs. If any smoke or odor becomes apparent, un-
plug the power cord and contact your dealer. Do not try to repair the device yourself.
Avoid using physically damaged devices. If your device metal housing is seriously physically
damaged, the internal components may function abnormally. Contact your dealer.
Do not install the device in an area heavy with dust or constant high humidity. Operating the
device in this case may result in fire or electric shock.
Only use supplied power supply. For a list of other compatible medical grade power sup-
plies, contact your dealer.
Install this device in a secure location where it cannot be easily pushed or knocked over.
Use of this device is not suitable for use within 6 ft. of a medical patient.

8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
TABLE OF CONTENTS
PRODUCT DESCRIPTION
OPERATION CONTROL AND FUNCTIONS
FRONT/REAR PANEL
TELNET COMMANDS
CONFIGURATION
SPECIFICATIONS
MAINTENANCE AND TROUBLESHOOTING
SERVICE PROCEDURE
REPLACEMENT POLICY
RETURN AND REPAIR SERVICE
LIMITED WARRANTY
5
6
6
7
8
34
35
36
36
36
37
1.0
2.0
2.1
3.0
4.0
5.0
5.1
5.2
6.0
7.0
8.0

8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
5
PRODUCT DESCRIPTION
The LB-KP8E-ICP (8-Button) and LB-KP16E-ICP (16-Button) Wall Plate
Ethernet Keypad offers 8 or 16 direct macro command buttons in an
elegant decora style wall plate form factor to provide end-users an
intuitive interface to control the various control functions configured
in the Integrated Control Processor (LBC-H/O-R-ICP). Integrated PoE
functionality eliminates the need for additional power supplies by
offering the capability to remotely power the wall plate over Ethernet.
Each button is easily custom labeled to identify the button’s function.
Features include:
• 1-gang wall plate Ethernet keypad with 8 buttons (LB-KP8E-ICP)
• 2-gang wall plate Ethernet keypad with 16 buttons (LB-KP16E-ICP)
• Can be powered over Ethernet with PoE (Power over Ethernet) or DC
power supply
• Easily integrates with the Integrated Control Processor (LBC-H/O-R-
ICP)
• Extra virtual buttons are available via WebGUI configuration
• Comes with relays to control peripheral device on/o
• Available with PoE function or DC power supply selection
• Supports Telnet or WebGUI control
• Supports scheduling control and settings
• Adjustable LED dim light in keypad buttons

6
8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
OPERATION CONTROL AND FUNCTIONS
DC 5V
+
-
Relay
Out
Control
FRONT PANEL
1
BACK PANEL
2
Macro Buttons: Each button has 2 colors of LEDs adjustable from dim 0~100% and can
have up to 16 commands. Further detail settings can be found in Section
2.5
Relay Out: Connect with device that supports DC 0~24V/5A power or signal that sup
ports relay function.
Control: Connect from PC/Laptop with active internet service or Telnet or WebGUI
control with RJ-45 terminated cable. This slot supports PoE PD 48V
function which means when the connected server/Hub support PSE 48v it
can be powered without DC supply connection.
DC 5V: Plug the 5V DC power adaptor included in the package and connect to AC
wall outlet for power supply.
1
2
3
4
3
4

8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
7
TELNET COMMANDS
COMMAND DESCRIPTION PARAMETER
IPCONFIG DISPLAYS THE CURRENT IP CONFIGURATION NONE
SIPADDR XXX.
XXX.XXX.XXX SET ETHERNET IP ADDRESS XXX=0-255
SNETMASK XXX.
XXX.XXX.XXX SET ETHERNET NET MASK
XXX=0-255
SGATEWAY XXX
XXX.XXX.XXX SET ETHERNET GATEWAY XXX=0-255
SIPMODE N SET ETHERNET IP MODE N=STATIC/DHCP
VER SHOW UNTIL FIRMWARE VERSION NONE
FADEFAULT ALL CONFIGURE AND MACRO
SET TO FACTORY DEFAULT NONE
ETH_FADEFAULT ALL ETHERNET CONFIGURE SET TO FACTORY* NONE
REBOOT SYSTEM REBOOT NONE
HELP SHOW COMMAND LIST NONE
HELP N SHOW DESCRIP OF COMMAND N: COMMAND NAME
RELAY N N1 RELAY CONTROL N(PORT)=1
N1=OPEN/CLOSE/TOGGLE
LEDBLUE N N1 LED BLUE BACKLIGHT CONTROL N(LEN NO.)~1-8
N1=% (1-100)
LEDRED N N1 LED RED BACKLIGHT CONTROL N(LEN NO.)~1-8
N1=% (1-100)
LEDBLUES N ALL BLUE LED BACKLIGHT CONTROL N=% {0-100}
LEDREDS N ALL RED LED BACKLIGHT CONTROL N=% {0-100}
LEDSHOW N LED DIMMING MODE CONTROL LEDSHOW N
N=ON/OFF/TOGGLE
BACKLIGHT N ALL LED BACKLIGHT CONTROL N=% {0-100}
KEY_PRESS N RELEASE
KEY_PRESS N HOLD KEY PRESS TRIGGER TYPE
KEY_PRESS N RELEASE
KEY_PRESS N HOLD
N=PORT NUMBER
N=PORT NUMBER
MACRO N MACRO SETTING
MACRO RUN N N=MACRO
ID (1-16)
MACRO STOP
TELNET_TIMEOUTN SET TELNET TIMOUT ON/OFF N=ON/OFF
NOTE: ANY COMMANDS WILL NOT BE EXECUTED UNLESS FOLLOWED
BY A CARRIAGE RETURN. COMMANDS ARE CASE-SENSITIVE

8
8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
CONFIGURATION
THE BACKGROUND
LIGHT BAR ALLOWS
USER TO INSTANT-
LY CHANGE THE
LEDS LIGHTING
PERCENTAGE
BASED ON THE
ORIGNIAL ILLUMI-
Telnet Control
Before attempting to use the Telnet control, please ensure that both the device under
control and the PC/Laptop are connected to the same active networks.
To access the Telnet control in Windows 7, click on the ‘Start’ menu and type “cmd” in
the Search field then press enter.
Under Windows XP go to the ‘Start’ menu and click on “Run”, type “cmd” with then press
enter.
Once in the command line interface (CLI) type “telnet”, then the IP address of the unit,
then hit enter.
This will bring us into the unit which we wish to control. Type “help” to list the available
commands.
Note: Commands will not be executed unless followed by a carriage return.
Commands are case-sensitive. If the IP is changed then the IP Address required for
Telnet access will also change accordingly. CLICK ON THE
EDIT SYMBOL TO
EDIT COMMAND
SETTINGS. UP/
DOWN ARROWS
ARE TO MOVE THE
COMMAND UP OR
DOWN AND DE

8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
9
CONFIGURATION
THE BACKGROUND
LIGHT BAR ALLOWS
USER TO INSTANT-
LY CHANGE THE
LEDS LIGHTING
PERCENTAGE
BASED ON THE
ORIGNIAL ILLUMI-
BUTTON CON
FIGURATION
ON THE TOP MENU
BAR CLICK ON CUS
TOMIZE AND THEN
CLICK ON 8/16
BUTTON KEYPAD.
WebGUI Control
On a PC/Laptop that is connected to an active network system, open a web browser
and type device’s IP address on the web address entry bar. A security page will appear
to ask for User and Password, please key in “admin” for both to enter.
Note: The Default IP setting is DHCP.
The browser will display the device’s Macro Setting, Extension Macro, Command
Settings, Schedule, Network and System Settings pages for users to control.
CLICK ON THE
EDIT SYMBOL TO
EDIT COMMAND
SETTINGS. UP/
DOWN ARROWS
ARE TO MOVE THE
COMMAND UP OR
DOWN AND DE

10
8-Button Wall Plate Ethernet Keypad User Manual (LB-KP8E-ICP / LB-KP16E-ICP)
CONFIGURATION
THE BACKGROUND
LIGHT BAR ALLOWS
USER TO INSTANT-
LY CHANGE THE
LEDS LIGHTING
PERCENTAGE
BASED ON THE
ORIGNIAL ILLUMI-
Macro Settings
The Background Light Bar allows user to instantly change the LEDs lighting percentage
based on the orignial illumination setting.
There are 6 Macros pre-configured as default setting for testing the Wall-Plate Control
System’s functionality. Click on Macro 1~6 to demonstrate the function of lighting LEDs.
• Macro 1: Light up the Red backlight LED with 100% brightness sequentially from 1~8
with every 500ms.
• Macro 2: Light up the Blue backlight LED with 100% brightness sequentially from
1~8 with every 500ms.
• Macro 3: Switch o all the read backlight LED with 0% brightness.
• Marco 4: Switch o all the blue backlight LED with 0% brightness.
• Marco 5: LED show mode toggle, swith o Demo Mode
• Macro 6: Light up the Blue backlight LED with 10% brightness, Switch o all the
blue backlight LED with 0% brightness, switch O & On Relay 1 with delay of
1000ms.
To disable default testing mode, set Demo Mode switch to o.