10 User manual IRON DOG 03 (1.0) © 2013 Brunner GmbH
values1)
nominal heat output kW 7
flue gas stream g/s 7,6
flue gas temperature (at port) °C 353
necessary draft Pa 12
consumption/ h kg 2
space heating capacity m350 - 90
degree of efficiency % 80,6
combustion air consumption m3/h 15
appliance data
dimension (h x b x t) mm 760 x 390 x 560
glass pane surface (h x b) mm 195 x 160
combustion chamber opening (h x b) mm 208 x 195
flue diameter space heating capacity rear wall
flue diameter mm 130
permitted fuel quantity kg 1,5 - 2,5
combustion chamber depth cm 38
recommended log length cm 25 - 33
cast iron weight kg 135
required minimum clearances
to the side wall cm 80
to the rear wall (with insulation panel) cm 30
to the rear wall (without insulation panel) cm 40
approvals
CE nach EN 13240
1) The data was determined in an EN 13240 test with a chimney stove with
a horizontal smoke tube connection, tube length 35 cm.