Carel PlantVisorPRO Handbuch

PlantVisorPRO Embedded
Foglio istruzioni
Technical leaflet

Technical leaflet

IMPORTANT WARNINGS
CAREL bases the development of its products on several years’ experience in the HVAC field, on continuous investment in technological
innovation of the product, on rigorous quality procedures and processes with in-circuit and function tests on 100% of its production, on
the most innovative production technologies available on the market. CAREL and its branch offices/affiliates do not guarantee, in any
case, that all the aspects of the product and the software included in the product will respond to the demands of the final application,
even if the product is built according to state-of-the-art techniques. The client (builder, developer or installer of the final equipment)
assumes every responsibility and risk relating to the configuration of the product in order to reach the expected results in relation to the
specific final installation and/or equipment. CAREL in this case, through specific agreements, can intervene as consultant for the positive
result of the final start-up machine/application, but in no case can it be held responsible for the positive working of the final
equipment/apparatus.
The CAREL product is a state-of-the-art product, whose operation is specified in the technical documentation supplied with the product
or can be downloaded, even prior to purchase, from the website www.carel.com.
Each CAREL product, in relation to its advanced technological level, needs a phase of definition / configuration / programming /
commissioning so that it can function at its best for the specific application. The lack of such phase of study, as indicated in the manual,
can cause the final product to malfunction of which CAREL can not be held responsible.
Only qualified personnel can install or carry out technical assistance interventions on the product.
The final client must use the product only in the manner described in the documentation related to the product itself.
Without excluding proper compliance with further warnings present in the manual, it is stressed that in any case it is necessary, for each
Product of CAREL:
•To avoid getting the electrical circuits wet. Rain, humidity and all types of liquids or condensation contain corrosive mineral substances
that can damage the electrical circuits. In any case, the product should be used and stored in environments that respect the range of
temperature and humidity specified in the manual.
•Do not install the device in a particularly hot environment. Temperatures that are too high can shorten the duration of the electronic
devices, damaging them and distorting or melting the parts in plastic. In any case, the product should be used and stored in
environments that respect the range of temperature and humidity specified in the manual.
•Do not try to open the device in any way different than that indicated in the manual.
•Do not drop, hit or shake the device, because the internal circuits and mechanisms could suffer irreparable damage.
•Do not use corrosive chemical products, aggressive solvents or detergents to clean the device.
•Do not use the product in application environments different than those specified in the technical manual.
All the above reported suggestions are valid also for the control, serial unit, programming key or nevertheless for any other accessory in
the product portfolio of CAREL.
CAREL adopts a policy of continuous development. Therefore, CAREL reserves the right to carry out modifications and improvements on
any product described in the present document without prior notice.
The technical data in the manual can undergo modifications without obligation to notice.
The liability of CAREL in relation to its own product is regulated by CAREL’s general contract conditions edited on the website
www.carel.com and/or by specific agreements with clients; in particular, within the criteria consented by the applicable norm, in no way
will CAREL, its employees or its branch offices/affiliates be responsible for possible lack of earnings or sales, loss of data and
information, cost of substitute goods or services, damage to things or persons, work interruptions, or possible direct, indirect, incidental,
patrimonial, of coverage, punitive, special or consequential in any way caused damages, be they contractual, out-of-contract, or due to
negligence or other responsibility originating from the installation, use or inability of use of the product, even if CAREL or its branch
offices/affiliates have been warned of the possibility of damage.
Disposal of the product
The appliance (or the product) must be disposed of separately in accordance with the local waste
disposal legislation in force

CONTENTS
1. Introduction ................................................................................................................................................................................. 11
2. Installation................................................................................................................................................................................... 12
3. Technical specifications ............................................................................................................................................................... 16
4. Dimensions.................................................................................................................................................................................. 16
5. Accessories................................................................................................................................................................................. 16
6. Note ............................................................................................................................................................................................ 16


PlantVisorPRO Embedded
Cod. +050000625 - Rel. 1.1 26/06/07 11
1. Introduction
CAREL presents a new solution for the monitoring and telemaintenance of air-conditioning and refrigeration systems.
This solution is made up three fundamental parts: a device featuring exceptional stability and reliability, a robust operating
system that offers excellent performance, and a monitoring and telemaintenance product that has been tested and
appreciated in hundreds of installations (PlantVisorPRO). The purpose of this document is to provide instructions on setting up
the system.
1.1 Markings and connectors
Front panel
1
Fig. 1.1
1. Supervisory system ON/OFF
Rear panel
1. Power cable
2. Serial ports
3. Parallel port
4. Analogue modem telephone connector
5. Video connector
6. Ethernet network connector
7. USB ports
8. Mouse and keyboard connector
1235
4
6 7 8
LINE
Fig. 1.2
PlantVisorPRO Embedded / controllers connections
COM 2
LINE
Fig. 1.3

PlantVisorPRO Embedded
Cod. +050000625 - Rel. 1.1 26/06/07 12
2. Installation
The system is supplied with a black and white cable that must be connected to position (8). This cable should then be
connected to a mouse and a keyboard, the mouse to the black end and the keyboard to the white end. Once the mouse and
the keyboard have been connected, plug the monitor into connector (7). Then plug the power cable into connector (1) and
the 220 Vac power supply. Finally, connect the CAREL 485 network. The connector used depends on the type of converter
selected. The system is supplied together with the CAREL PC-GATE converter. To use this converter, connect the serial cable
to the COM2 port, that is, connector (2). To use the 485 USB converter (CVSTDUMOR0), any of the USB ports can be used,
connector (5). Optional: if the PlantVisorPRO Embedded needs to be connected to an Ethernet network, plug the network
cable into connector (6). Connector (3) can be used to interface to a parallel printer.
2.1 Setup
Once the cables have been connected (see the previous paragraph), switch the system on using button (1). At the end of
start-up phase, the following screen is displayed, prompting the user to select the language the screens will be displayed in.
Once having made the selection, click “OK”.
Fig. 2.1
Then the user license must be accepted; click “Next >”.
Fig. 2.2

PlantVisorPRO Embedded
Cod. +050000625 - Rel. 1.1 26/06/07 13
Wait until the “Install language” button is enabled, then select the language for installing PlantVisorPRO, and click “Install
language”.
Fig. 2.3
Once installation is complete, the following screen is displayed:
-click “ignore” to not install extra modems for the time being
-click “modem settings” to install an extra modem now
Fig. 2.4

PlantVisorPRO Embedded
Cod. +050000625 - Rel. 1.1 26/06/07 14
The last screen displayed is the following:
-click “ignore” to not install a printer for the time being
-click “printer settings” to install a printer now
Fig. 2.5
2.2 Configuration
At the end of start-up phase (see the previous paragraph), the PlantVisorPRO management console is opened. This indicates
that the system is fully operating.
Fig. 2.6
The ”System Manager” button allows to access the operative system. The access to these functions is password protected.
Only two users can access these functions. The users in question have the following profiles “administrator” and
“maintenance”. The first features “PVPROAdmin” as login and “12345678” as password, the second “PVPROInstaller” as
login and “12345678” as password.
We suggest to change the password after the first access to the system.
Fig. 2.7

PlantVisorPRO Embedded
Cod. +050000625 - Rel. 1.1 26/06/07 15
Once the password has been entered, the following window will be displayed.
Fig. 2.8
To access the desired function, simply select it and click Run. To exit, simply click Close.
The following functions are available:
9Task Manager. Manages the processes that are currently running
9Explorer. Accesses the operating system shell.
9Restart the system.
9Close System. Physically shutdown the system.
9Configure the video adapter.
9Configure the network. This should be used if the system is connected to a network with domain.
9Configure date/time. This is used to set the date and the time of the system, as well as a set the time zone.
9Configure modem.
9Computer management. This is used to access the programs for managing the operating system.
9Configure keyboard. This is used to select the layout of the keyboard.
9User license. Displays the conditions of use.
9Configure printers and fax. This is used to open the window for installing a printer in the system.
9Safely remove hardware.
9On screen keyboard
9Calibrate monitor.
9Browser in Kiosk mode. Activating this functions displays the pages in full screen mode. To switch from the pages to
the supervisor monitor press ALT+TAB.
Andere Handbücher für PlantVisorPRO
1
Inhaltsverzeichnis
Andere Carel Steuerungssystem Handbücher

Carel
Carel FLSTDMAHUE Bedienungsanleitung

Carel
Carel Hecu CO2 Bedienungsanleitung

Carel
Carel pAD ADP 30 Series Bedienungsanleitung

Carel
Carel infrared IR32CE Series Bedienungsanleitung

Carel
Carel IROPZ48500 Bedienungsanleitung

Carel
Carel WM00E 00 Series Bedienungsanleitung

Carel
Carel MasterCella Split Bedienungsanleitung

Carel
Carel DPWL Series Bedienungsanleitung

Carel
Carel Heez Handbuch

Carel
Carel MPXone series Bedienungsanleitung