1. Model and serial number - Located on the front of the bucker
2. Proof of purchase date
3. A copy of the original Warranty Registration Card or Online Submission
4. Details of the defect or problem (include photos and videos)
YOU MAY BE DENIED WARRANTY COVERAGE IF YOUR MACHINE HAS FAILED
DUE TO ANY OF THE FOLLOWING:
Product abuse Normal wear
Product neglect Accidental damage
Improper maintenance Unapproved modications
Improper electrical connection
OWNERS MANUAL
THE TABLETOP

For more information or to watch our video tutorials visit cprosolutions.com
OWNERS MANUAL
GENTLE CUT - GC BUCKERS
3
GENERAL
• Do not move, disassemble, clean or inspect the Bucker while the power is still connected to the machine.
• The Buckers are very heavy - Never lift alone and always use proper lifting techniques.
• Ensure unit is secured to the stand, or is on a hard and leveled surface.
• Replacement parts are specic to The Buckers and must be purchased from an authorized dealer only.
• Substituting factory parts with non-approved third-party replacements may result in damage to the
machine or bodily harm.
• Keep all individuals a safe distance from the work area. Do not operate the machine around children.
• Do not remove safety labels. Replace any and all labels if they become damaged or obscured
CONNECTION
• As with home appliances, GC Buckers must be used in connection with a properly
grounded receptacle.
• Never plug in or power up your Bucker machine if the protective shrouds are removed.
• Do not use extension cords smaller than 12 gauge or longer than 7.6m (25ft) in length
to power the Bucker.
• Using unrated extension cords can cause motor overheating and premature failure.
The GC Buckers are a high-powered machines that require special safety precautions to be practiced while in operation to reduce the risk of personal injury.
Improper use of the GC Bucker may cause serious or fatal injury. Please read the precautions and warning labels before using the GC Bucker.
IMPORTANT SAFETY INFORMATION
CENTURION PRO SOLUTIONS:
GC BUCKERS
OPERATION
• GC Buckers comes from the manufacturer set with the optimal blade rotation. The initial set up will
show assembly instructions.
• Safety glasses and dust masks must be worn at all times when operating Buckers.
• Do not operate any Bucker machine while tired or under the inuence of medication, drugs
or alcohol.
• Do not put anything other than plant material into the Bucker. Doing so may cause damage to the
machine or result in bodily harm.
• Operate the Bucker in a well ventilated area in order to prevent overheating.
MAINTENANCE
• Never leave the GC Bucking system running unattended.
• Never conduct maintenance or cleaning while the machine is plugged in.
• Do not modify or adapt any part of the Bucker or its accessories. Doing so may cause irreversible
damage to the machine or result in bodily harm.
DO NOT LEND OUT OR RENT YOUR GC BUCKER WITHOUT THIS OPERATING MANUAL.
A FIRST TIME USER SHOULD OBTAIN PROPER INSTRUCTION PRIOR TO USE.
0PERATING THE GC BUCKER WITHOUT READING THE INSTRUCTIONS THAT ACCOMPANY A CAUTIONARY LABEL
(IE. "DANGER", "CAUTION", "WARNING", OR "NOTICE" SYMBOL), MAY RESULT IN SERIOUS OR FATAL INJURY.
FOR OPTIMAL PERFORMANCE AND LIFE, THE BUCKER BLADE
MUST BE REMOVED AND CLEANED AFTER DAILY USE.
G
o
o
d
M
a
n
u
f
a
c
t
u
r
i
n
g
P
r
a
c
t
i
c
e
C
o
m
p
l
i
a
n
t
GC BUCKER AIR BLOWER

DRY BUCKING TIPS
3 STEPS FOR OPTIMAL PROCESSING
ENVIRONMENT PREPARATION
• Ensure adequate space
• Review electrical requirements
• Have adequate bins for product transport
• Cooler temperatures in processing room is
bene cial
PLANT PREPARATION
• Cut main stalk
• Seperate each individual stem
(no 'y' junctions)
• Leave 3" of stem for clearance into machine
• Ensure clean angled cuts for precise feeding
FEEDING
• Keep prepped product stem side up for
effi ciency
• Size the stem to t the ideal hole
• Feed end rst into machine
FOLLOW US ON:
1.855.535.0558 www.cprosolutions.com[email protected]om
MOISTURE CONTENT
• If fl owers are too dry, colas may fall apart
when destemmed
• Optimal moisture content: 12% - 14%
• Let the GC bucker gently slice stem from
fl ower, rather than pulling or popping
FLOWER CONSISTENCY
• Small stems should snap when bent, but
big stalks should remain pliable
• If stems are too brittle, they may break
upon entering the machine
• Buds should be “springy” and return to
their original shape when squeeze
FEED RATE
• Insert stalks slowly, controlling the feed rate
• Handle dry plants delicately
• Catch de-stemmed fl owers as they are
sliced from stalks
PLANT PREPPING 101

For more information or to watch our video tutorials visit cprosolutions.com
OWNERS MANUAL
GENTLE CUT - GC BUCKERS
5
TABLE OF CONTENTS
GC3 - ADDITIONAL REQUIREMENTS
EXTENSION CORD
12 AWG (min AWG SIZE)
7.6m/25ft MAX LENGTH
GC1 - ADDITIONAL REQUIREMENTS
EXTENSION CORD
14 AWG (min AWG SIZE)
7.6m/25ft MAX LENGTH
HP BUCKER CONNECTIONS
EUROPE, SOUTH AMERICA & ASIA
CONNECTOR PLUG
REGULAR WALL OUTLET
HP BUCKER CONNECTIONS
CANADA, USA, MEXICO & JAPAN
CONNECTOR PLUG
REGULAR WALL OUTLET
WARRANTY
IMPORTANT SAFETY INFORMATION
PLANT PREP 101 - 3 STEPS FOR OPTIMAL PROCESSING, DRY BUCKING TIPS
TABLE OF CONTENTS
COMPONENT OVERVIEW
ASSEMBLY TO SINGLE STAND (GC1)
ASSEMBLY TO TRIPLE STAND (GC3)
CLEANING & MAINTENANCE
BLOWER CLEANING & MAINTENANCE
BUCKER SPECIFICATIONS
GENERAL OPERATIONS
TROUBLESHOOTING
FREQUENTLY ASKED QUESTIONS
RETURN/REFUND POLICY
2
3
4
5
6
7
8
9
10
11
12
13
13
13

6cprosolutions.com1 855 535 0558
COMPONENT OVERVIEW
50490
BLOWER
NA (0.25HP 60HZ)
EU/AUS (0.25HP 50HZ)
50460
SIDE PLATE
RIGHT
50477
TOP PLATE 50473
BOTTOM PLATE
LEFT
50478
BEARING BAR
50472
CROSS BAR
FRONT
50474
BOTTOM PLATE
RIGHT
50481
COVER
50472
CROSS BAR
BACK
50468
LEG
50151 (60 HZ)
51031 (50 HZ)
MOTOR
50475
CUTTING BLADE
50484
PULLEY
0.625-2 OD
CP-7014
MOTOR PLATE
50461
SIDE PLATE
- HOLE LEFT

For more information or to watch our video tutorials visit cprosolutions.com
OWNERS MANUAL
GENTLE CUT - GC BUCKERS
7
GC3 TRIPLE BUCKER SPECIFICATIONS
GC3 BUCKER
Input Voltage NA: 25 Amp - 110V, 60Hz Single Phase
EU, AUS: 9 Amp - 220V, 50Hz Single Phase
Current Draw < 23A Operating
Motor 0.25HP (x3)
Motor RPM 1750 RPM (x3)
Weight (w/ stand) 391lbs / 212kg
Length 102in / 259cm
Width 32.5in / 82.55cm
Height 55in / 140cm
Circuit Breaker Required NA: 30A/120V
EU, AUS: 20A/220V
GC3 BUCKER FEATURES
Feed Throughput +120lbs/hr (Hydrated)
Feed Entry Sizes 3-hole (3/16”, 1/4”, 3/8”)
Feed Types Wet/Dry
GMP Compliant* Yes
UL Compliant* Yes
CE Compliant* Yes
RoHS Compliant* Yes
Primary Material 304 Stainless Steel / Aluminum
GC1 BUCKER SPECIFICATIONS
GC1 BUCKER
Input Voltage NA: 6 Amp - 110V, 60Hz Single Phase
EU, AUS: 3 Amp - 220V, 50Hz Single Phase
Current Draw < 3A Operating
Motor 0.25HP
Motor RPM 1750 RPM
Weight (w/o stand) 65lbs / 29.5kg
Length (w/o stand) 15in / 38cm
Width (w/o stand) 27.5in / 70cm
Height (w/o stand) 18in / 46cm
Circuit Breaker Required NA: 15A/120V
EU, AUS: 15A/220V
GC1 BUCKER FEATURES
Feed Throughput +40lbs/hr (Hydrated)
Feed Entry Sizes 3-hole (3/16”, 1/4”, 3/8”)
Feed Types Wet/Dry
GMP Compliant* Yes
UL Compliant* Yes
CE Compliant* Yes
RoHS Compliant* Yes
Primary Material 304 Stainless Steel / Aluminum

8cprosolutions.com1 855 535 0558
STEP 1:
REMOVE
LEGS
STEP 2:
ATTACH TRIM
SAVER BAG
ASSEMBLY TO SINGLE STAND
Unscrew
legs from
the inside.
STEP 3:
MOUNT BUCKER
ONTO STAND
A) Line up existing holes on the
Bucker to the holes on the
adapter plate. Attach using:
4 - 3/8" x 1" bolts
4 - 3/8" nuts
4 - 3/8" x 7/8" washers
B) Line up existing holes
on the stand to the
holes on the adapter
plate. Attach using:
7 - 3/16" x 0.75" bolts
Repeat 3x for the Triple Stand
GC1
Re-assemble bucker
in reverse order as
per "Cleaning &
Maintenance".
STEP 4:
REASSEMBLE
BUCKER
*STAND SOLD SEPERATELY
*Ensure machine is unplugged before cleaning.

For more information or to watch our video tutorials visit cprosolutions.com
OWNERS MANUAL
GENTLE CUT - GC BUCKERS
9
STEP 1:
MOUNT BUCKER
ONTO TRIPLE
STAND
STEP 3:
CONNECT FLEX
DUSTING HOSE
TO BLOWER
Attach ex dusting hose
to all 3 workstations on
bottom of Bucker using
??? screws.
Re-assemble bucker in
reverse order.
STEP 2:
CONNECT FLEX
DUSTING HOSE
TO BUCKER
STEP 4:
REASSEMBLE
BUCKER
A) Line up existing holes on the
Bucker to the holes on the
adapter plate. Attach using:
4 - 3/8" x 1" bolts
4 - 3/8" nuts
4 - 3/8" x 7/8" washers
A) Attach 3-head diverter to
blower using: 1 - 0.25"
phillips head screw
B) Line up existing holes
on the stand to the
holes on the adapter
plate. Attach using:
7 - 3/16" x 0.75" bolts
B) Attach the other end of
the ex dusting hose
from each Bucker, to
the Blower's diverter
ports by securing it
with a 3" hose clamp.
3" hose clamp.
3" hose clamp.
ASSEMBLY TO TRIPLE STAND
GC3
*Ensure machine is unplugged before cleaning.

10 cprosolutions.com1 855 535 0558
STEP 1:
REMOVE
BEARING BAR
STEP 4:
BLADE
CLEANING
4 - 3/16" hex top x 0.75" bolts 10 - 3/16" hex top x
0.5" bolts
Clean the BLADE of
debris by soaking
in warm water and
wiping down with
alcohol.
Re-assemble bucker
in reverse order.
Please refer to
"Blower Maintenance & Cleaning"
section of the manual.
2 - 1/8" x 0.5" bolts
STEP 2:
REMOVE TOP
PLATE
STEP 5:
CLEAN
BLOWER
STEP 3:
BLADE
REMOVAL
STEP 6:
REASSEMBLE
BUCKER
CLEANING & MAINTENANCE *Ensure machine is unplugged before cleaning.
FOR OPTIMAL PERFORMANCE AND LIFE,
THE BUCKER BLADE MUST BE REMOVED
AND CLEANED AFTER DAILY USE.
Andere Handbücher für GC1
1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere CenturionPro Trimmer Handbücher

CenturionPro
CenturionPro XL Series Bedienungsanleitung

CenturionPro
CenturionPro 3.0 Bedienungsanleitung

CenturionPro
CenturionPro THE MINI Bedienungsanleitung

CenturionPro
CenturionPro Original Bedienungsanleitung

CenturionPro
CenturionPro DBT 4 Bedienungsanleitung

CenturionPro
CenturionPro Original Bedienungsanleitung

CenturionPro
CenturionPro The Gladiator Bedienungsanleitung