CESCO GlucCell Bedienerhandbuch

GlucCell
TM
Glucose Monitoring System
User Instruction Manual
Ver.1.1
Caution
Read the User’s Manual thoroughly before use.
This User’s Manual is designed to guide you through the
operation of the GlucCellTM Glucose Monitoring System with
detailed directions and illustrations. Read the entire the User’s
Manual before you begin test to ensure that you use this
system properly and receive accurate results.
GlucCellTM is a trade mark of CESCO Bioengineering Co., Ltd.

1
Contents
Chapter 1 About the GlucCellTM System........................3
1.1 Intended Use.......................................................3
1.2 Characteristics ...................................................3
1.3 Limitations of the system ..................................3
1.4 Component List..................................................4
1.5 About the Glucose Meter...................................4
1.5.1 Front-side of the Meter ............................4
1.5.2 Backside of the Meter..............................4
1.5.3 LCD Display..............................................5
1.6 About the Glucose Test Strip ............................5
1.6.1 Glucose Test Strip....................................5
1.6.2 Test Strip Vial ...........................................5
1.7 About the Check Strip........................................6
1.8 About the Code Key ...........................................6
Chapter 2 Install/Replace Battery ..................................6
2.1 How to install/replace the battery .....................6
WARNING..................................................................7
Chapter 3 Set the Glucose Meter ...................................8
3.1 How to enter into Set Mode...............................8
3.2 Setting the Year ..................................................8
3.3 Setting the Month...............................................8
3.4 Setting the Day ...................................................9
3.5 Setting the Hour .................................................9
3.6 Setting the Minutes ............................................9
3.7 Setting the Unit of Measurement ......................9
Chapter 4 Code the Glucose Meter..............................10
4.1 Why to code the meter.....................................10
4.2 When to code the meter ..................................10
4.3 How to Code the Meter ....................................10
Chapter 5 Perform a Glucose Test...............................11
Chapter 6 Test Results ................................................13
6.1 What your results mean...................................13
6.2 Low Glucose Value ..........................................13
6.3 High Glucose Value..........................................13
Chapter 7 Memory Recall .............................................14
7.1 How to enter into Memory Mode.....................14

2
7.2 Memory Recall..................................................14
Chapter 8 Quality Control Test.....................................15
8.1 Quality Control by using the Check Strip ......15
Chapter 9 Display Message and Solution ...................15
Chapter10 Taking Care of your Glucose Meter...........17
Chapter11 Specifications of the System .....................18
Chapter12 Customer Service .......................................18

Chapter 1. About the GlucCellTM System
1.1 Intended Use
The GlucCell TM Glucose Monitoring System is intended for use by
laboratory researchers or bioreactor professionals to obtain a
quantitative measurement of glucose in cell culture media.
1.2 Characteristics
The GlucCellTM Glucose Monitoring system is a merging of glucose
biosensor technology with microprocessor-based instrumentation.
The glucose test strip requires a sample volume of less than 3 uL and
has a testing time of less than 15 seconds. The glucose meter is a
compact hand-held device with a large and easy-to-read display. The
meter can store 180 test results with corresponding times and dates.
1.3 Limitations of the system
3
!
!
!
!
!
!
!
!
For in vitro research use only. Not for diagnostic testing.
GlucCellTM Glucose Test Strips can be used only with GlucCellTM
Glucose Meters.
The meter must be coded only with the corresponding code on the
vial of glucose test strips being used - the codes must match.
Use glucose test strips before their expiration date.
Test only with cell culture medium or equivalent buffer solution.
High concentrations of vitamin C and/or uric acid may affect the
test result.
High altitudes may affect the test result.
Temperatures outside the range of 10℃to 40℃(50℉to 104℉)
may affect the test result.

4
1.4 Component List
These items are included in your starter kit of GlucCellTM Glucose
Monitoring System:
1. User’s Manual 1
2. Quick Reference Card 1
3. Glucose Meter 1
4. Glucose Test Strip *
5. Check Strip 1
6. Code Key 1
7. 3V Li+ Battery (inside the meter) 1
8. Carrying Bag 1
* Quantity varies according to the order
8
6
5
4
3
1.5 About the Glucose Meter
1.5.1 Front-side of the Meter
1 LCD Display:
Shows test results and other information.
2 Mem/Set Button(M/S Button):
# Turns the meter on/off (press and hold for
4 secs to turn off)
# Enters into Memory Mode
# Changes parameters in Set mode
3 Func. Button(Func. Button):
# Turns the meter on
# Enters into Set Mode
# Confirms parameters in Set Mode
4 Strip Slot:
The slot is a connector for the glucose test strip,
Code Key, and Check Strip.
2
3
1
4
1.5.2 Backside of the Meter
1 Data Port:
Used with the optional GlucCell TM transferring cable
and GlucCellTM Manager software for data transfer
from the meter to a computer for analysis.
2 Battery Cover:
Slides down for battery access.
2
1

5
1.5.3 LCD Display
1 Numerical Display: Data display
2 Battery symbol: Low battery indication.
3 Thermometer symbol:
Out-of-range temperature indication.
4 droplet symbol: Ready for test indication.
5 Strip symbol:
Ready for strip insertion indication.
6 M188: Memory number display.
7 mg/dL; mmol/L: Selected unit display.
8 DAYAVG:
Number of days average display.
9 Date: Month/day display.
10 Time: Time display.
1.6 About the Glucose Test Strip
1.6.1 Glucose Test Strip
1 Connector End
2 Sample Chamber (on the rear side of
test strip)
3 Reaction zone
Rear
Front
2
2
1
3
1.6.2 Test Strip Vial
1 Code Number
2 Expiration Date
3 Discard Date:
90 days from first opening of vial.
3
2
1

6
1.7 About the Check Strip
The Check Strip is used to check the function of
the meter
1 Connector End
1.8 About the Code Key
1 Connector End
2 Code Number:
The code number on the Code Key must
match with code number on the test strip vial
being used.
Chapter 2 Install/Replace Battery
2.1 How to install/replace the battery
1 Push the battery cover with two thumbs and
slides down to open.
2 Replace with a 3.0 volt lithium battery (CR 2032)
into the battery compartment with the positive
(+) side up.
3 Slide the Battery Cover up (until it snaps into
place) to close.
Notes

7
Test results that are stored in memory will not be erased when you
replace the battery., if the new battery is installed needed within 30
minutes
WARNING
Discard the used battery according to your local environmental
regulations.

Chapter 3 Set the Glucose Meter
3.1 How to enter into Set Mode
1 Press any buttons to turn on the meter
2 Press the “Func. button” four times slowly and
successively by following the rhythm of
flashing symbols to enter into Set Mode. The
year filed flashes will show up first.
3.2 Setting the Year
1 The Year field flashes.
2 Press the “Mem/Set button” to change the
Year.
3 Press the “Func. button” to confirm the new
setting and to cycle on to the next setting (i.e.,
month).
3.3 Setting the Month
1 The Month field flashes.
2 Press the “Mem/Set button” to change the
Month.
3 Press the “Func. button” to confirm the new
setting and to cycle on to the next setting (i.e.,
Day).
8

9
3.4 Setting the Day
1 The Day field flashes.
2 Press the “Mem/Set button” to change the Day.
3 Press the “Func. button” to confirm the new
setting and to cycle on to the next setting (i.e.,
Hour).
3.5 Setting the Hour
1 The Hour field flashes.
2 Press the “Mem/Set button” to change the
Hour.
3 Press the “Func. button” to confirm the new
setting and to cycle on to the next setting (i.e.,
Minutes).
3.6 Setting the Minutes
1 The Minutes field flashes.
2 Press the “Mem/Set button” to change the
Minutes.
3 Press the “Func. button” to confirm the new
setting and to cycle on to the next setting (i.e.,
Unit of Measurement).
3.7 Setting the Unit of Measurement
1 The Unit field flashes.
2 Press the “Mem/Set button” to change the Unit.
3 Press the “Func. button” to confirm the new
setting and to turn off the meter.
Notes
While in Set Mode, hold down the “Mem/Set button” to scroll through
the numbers quickly.
After the unit is set, the meter will turn off automatically.
Andere Handbücher für GlucCell
3
Inhaltsverzeichnis
Andere CESCO Blutzuckermessgerät Handbücher
Beliebte Blutzuckermessgerät Handbücher anderer Marken

ReliOn
ReliOn Prime Bedienerhandbuch

AgaMatrix
AgaMatrix Presto Bedienungsanleitung

Polymer Technology Systems
Polymer Technology Systems A1C Now Self Check Bedienungsanleitung

Medisana
Medisana GlucoDock Bedienungsanleitung

Arkray
Arkray ASSURE PLATINUM Bedienungsanleitung

Dexcom
Dexcom G4 Professional Bedienungsanleitung

LabStyle
LabStyle Dario Bedienungsanleitung

ACONLABS
ACONLABS ON CALL EXPRESS Bedienungsanleitung

Higi Technology
Higi Technology iGlucose Bedienungsanleitung

Bayer HealthCare
Bayer HealthCare CONTOUR NEXT Bedienungsanleitung

Accu-Chek
Accu-Chek ADVANTAGE Bedienungsanleitung

Sanofi-aventis
Sanofi-aventis BG STAR Technische Daten