___________________________________________________________________________________________________
I-ARRI-01.doc Issue 03 25th April 2016 4
IOM –ARRAN LED FLOODLIGHT (IND)
4.0 Inspection and Maintenance
Visual inspection should be carried out at a minimum of 12 monthly intervals and more frequently if conditions are severe.
Maximum Insulation Resistance Test 500V dc.
1 Check if any LED’s have failed (not lit).
2 The LEDs are mounted on boards, if there is 3 or more LED's not working on one board the light output will have
dropped to a level where the LED board may need replaced. Refer to 4.2 LED Replacement.
3 Check for mechanical damage/corrosion.
4 Check for loose connections including earthing.
5 Check for undue accumulations of dust or dirt.
6 Verification of tightness of fixing, glands, blanking plugs etc.
7 Check for unauthorised modifcations.
8 Check condition of enclosure gaskets and fastenings.
9 Check for any accumulation of moisture.
10 Clean the lampglass.
11 Check that mountings are secure.
12 If there is suspicion that the luminaire has suffered mechanical damage, a stringent workshop check should be made.
Important: Where spares are needed, these must be replaced with manufacturer parts. No modifications should be made
without the knowledge and approval of the manufacturer.
4.1 Electrical Fault Finding and Replacement
Any fault finding must be done by a competent electrician with the luminaire isolated and if carried out with the luminaire in
place, under a permit to work. Fault finding is by substitution with known good components.
4.2 LED Replacement.
The need and frequency of replacing LED’s be dependent on the functionality of the fitting. If it is continually running at high
ambient temperatures it will affect the frequency of LED replacement. If it is necessary to replace the LED’s, the LED’s are
mounted on boards that can be replaced individually. (The boards with LED's supplied by Chalmit ). Remove cover
assembly.
Removal of LED assembly is as follows:
1. Unscrew 5 off screws that secure the board to the casting.
2. Carefully lift the plate and disconnect push in connector.
Replacement of LED assembly is the reverse of the removal.
Replace Front cover and fully tighten all bolts.
5.0 Disposal of Material
The unit is mostly made from incombustible materials. The control gear contains electronic components and synthetic resin.
All these may give off noxious fumes if incinerated. Care must be taken to render these fumes harmless and avoid
inhalation. Any local regulations concerning disposal must be complied with. Any disposal must satisfy the requirements of
the WEEE directive [2012/19/EU] and therefore must not be treated as commercial waste.
To comply with the Waste Electrical and Electronic Equipment directive 2012/19/EU the
apparatus cannot be classified as commercial waste and as such must be disposed of or
recycled in such a manner as to reduce the environmental impact.