ASSEMBLY AND MOUNTING INSTRUCTIONS
Installing the Bulb
The bulb is stored within the lamp housing as illustrated in Fig. 1.
4
1. Remove the wing nut securing the handle where fitted,
and then the screw securing the lamp housing cover,
arrowedinFig.1,and install the halogen bulbas follows:
Holding the bulb with a soft cloth, carefully locate
one end into the ceramic mounting. Whilst pushing
the end of the bulb against the metal pin, gently slide
the other end of the bulb into position in the other
ceramic mounting until it is secure. Do not use force
when installing the bulb.
NOTE: DO NOT TOUCH THE BULB WITH FINGERS, this will cause
damage. If it has been touched, wipe it carefully with a
soft cloth dampened with methylated spirits.
2. When the bulb is in position, screw the lamp housing cover back firmly, ensuring the
gasket is correctly seated, then reattach the handle where fitted.
MODELS 150D & 500D ONLY
These models are designed for wall or other independant mounting and may be used with
PIR or other security systems. They are not supplied with electric cable.
The cable used should be suitable for outdoor use, 3-core with a conductor size of at least
1.5mm2, manufactured to BS6500.
Wiring up these models should be carried out as
follows:
1. Remove the cable gland and rubber
washer from the cable inlet and retain. Fig.
2 shows the gland and washer removed
from model 151D.
2. Remove the Terminal Box cover by
unscrewing the four securing screws.
3. Remove the screws securing the cable
clamp.
4. Thread the cable gland, followed by the
rubber washer over the cable, then thread
the cable through the cable inlet.
5 Carefully strip the outer insulation from the
conductors for a distance of approx. 30mm
taking care not to damage the conductor
insulation.
Strip the conductor insulation, for a distance
of approx. 8mm and twist the strands
together, on each conductor
Fig. 3.
Fig. 2.
Fig. 1.
6. Identify the terminals by observing the embossed
symbols on the base of the junction box, and
indicated in Fig.4.
These are L - Live, N - Neutral and earth.
Connect the conductors accordingly.
NOTE: The cable path for the 500SD is shown by the dotted
line in Fig. 3.
7. Replace the cable clamp ensuring it firmly clamps
the OUTER insulation, or sheathing, and NOT the
conductors.
5
8. Push the rubber washer into the cable inlet and screw in the cable gland firmly. Do
not overtighten as this could strip the plastic threads.
9. Before replacing the cover, ensure the terminal black is located snugly on the locating
pegs, illustrated in Figs. 3 and 4.
The cover should be firmly secured, but again, do not overtighten the screws.
Thelampmaybemountedto a convenient surface using the holes provided in the mounting
bracket, and then tilted to the desired angle. Tighten the mounting bracket pivot screws
(B, Fig.10) to secure.
MODELS 100D, 151D & 500SD
These models are mounted on a carry frame,
which is assembled as follows:
1. Remove the fixing screw (inset Fig.5) from the
base of the carry frame, then insert the tubular
base into the frame attachment, as indicated
in Fig. 5.
2. Line up the holes in the two sections of the
frame then replace and tighten the fixing screw.
ALL OTHER MODELS
Fig. 4.
Fig. 5.
All other models are tripod mounted, either single
lamp or twin.
The Tripod
The tripod is folded so that the legs lie flat along
the column.
To erect the stand, pull the legs away from the column
by prising them from within the support linkage, taking
carenottotrapyourfingers. Pullthelegsinthedirection
of the arrows shown in Fig. 6.
The hub will slide down the legs and the legs will
spread.
NOTE: It may be necessary to slacken the Leg Locking
Knob in order for the hub to move. Remember to
retighten when the legs are spread correctly.
Fig. 6.