Claro SUMMER DC Bedienungsanleitung

Installation Manual
VER 0.1
SUMMER DC

Ceiling fan instruction booklet
Thank you for purchasing your Claro Summer DC Ceiling Fan. Please read all instructions
carefully before assembly and use.
IMPORTANT SAFEGUARDS
Read all instructions carefully, even if you feel you are quite familiar with this type of appliance. When
using electrical appliances, in order to reduce the risk of re, electric shock, and/or injury, these
basic safety precautions should always be followed:
1. All wiring must be done by a licenced electrician as on-site warranty may be voided if proof
cannot be provided. This ceiling fan MUST be installed by a Qualied Electrical Contractor in
accordance with the local regulations, and all local, state and national electrical codes. Any
alterations or additions to building wiring must be completed by a licensed electrical contractor, or
person authorised by legislation to work on the xed wiring of any electrical installation.
2. The fan must be connected to a 240V AC 50Hz power supply.
3. All electrical work must only be undertaken after disconnection of the power by removing fuses
or turning o the circuit breaker, to ensure all pole isolation of the electrical supply.
4. The fan must be earthed.
5. The fan must be installed so that the blades are at least 2.1 metres above the oor.
6. The ceiling fan weight is max. 8 kg. The structure that the ceiling fan is mounted to must be
capable of supporting a weight of at least 45kg. The xing must be able to support the moving
weight of the fan and must not twist or work loose.
7. Make sure that the installation site will not allow the rotating fan blades to come into contact with
any object and that there is enough space from the blade tip to the wall or ceiling. Please note that
insucient clearance distances might cause wobbling and the bigger this clearance is the better the
airow from your fan will be.
8. DO NOT install CFCLSU2WH and CFCLSU2LWH outdoors. Installing the fan in a position where it
could be exposed to water, moisture or external elements is dangerous.
9. CFCLSU2WHABS and CFCLSU2LWHABS can be installed in a position where it is covered or
enclosed al fresco areas and there is a minimum clearance of 1.50 m from the blade tip to all edges
of the roof or positions where could be exposed to water, moisture or other dangerous external
elements.
10. DO NOT connect the fan motor to a dimmer switch. This may give an unsatisfactory
performance (motor hum) and cause damage to the motor and/or controller. Use ONLY the
provided remote control.
11. This appliance is not intended for use by young children or inrm persons without supervision.
12. Young children should be supervised to ensure that they DO NOT play with the appliance.
13. It is NOT recommended that ceiling fans and gas appliances be operated in the same room at
the same time.
14. The fan must be turned o and stopped completely before reversing the fan direction. This will
prevent any damage to the motor of the fan or controller.
15. Do not insert anything into the fan blades whilst they are spinning. This will damage the blades
and upset the balance of the fan causing the unit to wobble.
16. After the fan is completely installed make sure that all base and fan blade xings are secured and
tightened to prevent any problems.
17. Because of the fan’s natural movement, some connections may loosen. Check the support
connections, brackets and blade attachments twice a year to make sure they remain secured. If any
are loose, tighten.
18. If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact
the manufacturer, its service agent or suitably qualied persons.
19. The replacement of parts of the safety suspension system device shall be performed by the
1

manufacturer, its service agent or suitably qualied persons.
20. If it is necessary to replace the live or neutral brushes to ensure operation of the motor then
both brushes and the earth brush shall be replaced at the same time. The brushes shall only be
replaced by a suitably qualied person.
21. An all-pole disconnection incorporated in the xed wiring is to be provided, such as an all-pole
switch or a supply cord tted with a plug.
22. The light source in light kit is not replaceable; when the light source reaches its end of life the
whole light kit shall be replaced by manufacture, his service agent or a qualied person.
23. The max operating temperature for the fan is 40 °C. Keep the fan away from any heat sources,
like re place, heater and stove.
IMPORTANT NOTE:
The important safeguards and instructions given in this manual are not meant to cover all
possible conditions and situations that may occur. It must be understood that common sense,
caution and care are factors which cannot be built into any product.
CAUTION:
Do not ingest battery - Chemical burn hazard.
The remote supplied with this product contains a AAA batteries. If the battery is swallowed, it can
cause severe internal burns in just 2 hours and can lead to death.
Keep the new and used batteries away from children. Examine devices and make sure the battery
compartment is secure.
If the battery compartment does not close securely, stop using the product and keep it away from
children.
If you think batteries might have been swallowed or placed inside any part of the body, seek
immediate medical attention.
Call the Poisons Information Centre on 13 11 26 or go to a hospital emergency room.
Do not let the child eat or drink and do not induce vomiting. Dispose of used button batteries
immediately.
The battery supplied with this product is not to be recharged.
Dierent types of batteries or new and used batteries are not to be mixed. Battery to be inserted
with the correct polarity. + for positive, - for negative.
Exhausted batteries are to be removed from the appliance and safely disposed of.
If the appliance is to be stored unused for a long period, the batteries should be removed.
Dispose of used button batteries immediately.
Flat batteries can still be dangerous. the supply terminals are not to be short-circuited.
FAULT FINDER:
Always check the “Trouble Shooting Checklist” included in this booklet before seeking warranty
claim.
Mechanical noise may be noticed on installation. Allow at least 8 hours settling-in period.
Some fans may wobble more than others, even if they are identical. This does not necessarily
indicate a fault.
2

PARTS INCLUDED
Hanger Bracket
Canopy
Hanger Ball
Coupling Cover
Receiver
Light Kit
Motor Housing B
Motor Housing A
Remote Control
DC Motor
Blades
Blade Arm
Downrod
Coupler
PREPARATION:
1. Unpack your ceiling fan carefully, then remove all parts and components, and lay on a cloth or
soft surface to avoid damage. DO NOT lay the motor housing on its side, the housing may get
damaged.
2. Before commencing installation, check that all parts are included.
NB: You may need to remove all foam packaging material to ensure there are no missing parts.
3

INSTALLATION AND ASSEMBLY
CAUTION: Before installing the fan make sure you have turned OFF the electricity supply.
SELECTING A LOCATION:
SELECTING A LOCATION:
1. Choose a location for mounting the fan where the blades will have at least 2.1 metres of clearance
from the oor.
2. Make sure that the installation site will not allow the rotating fan blades to come into contact with
any object and that there is enough space from the blade tip to the wall or ceiling. Please note that
insucient clearance distances might cause wobbling and the bigger this clearance is the better the
airow from your fan will be.
3. DO NOT install CFCLSU2WH and CFCLSU2LWH outdoors. Installing the fan in a position where it
could be exposed to water, moisture or external elements is dangerous.
4. CFCLSU2WHABS and CFCLSU2LWHABS can be installed in a position where it is covered or
enclosed al fresco areas and there is a minimum clearance of 1.50 m from the blade tip to all edges
of the roof or positions where could be exposed to water, moisture or other dangerous external
elements.
5. Secure the hanging bracket to the ceiling joist or suitable structure that is capable of carrying a
load of at least 45Kg, with the two long xing screws provided. Ensure that at least 30mm of the
screw is threaded into the support.
The xing screws included are designed for use when ceiling fan is secured onto timber joists. For all
other surfaces, additional and suitable xing screws for that surface will need to be purchased.
4
ELECTRICAL CONNECTIONS
Ensure the power is o when installing this fan.

WIRING DIAGRAM
5
NO LIGHT
To Motor Wire
RECEIVER
Black Wire
Antenna Wire
To Motor Wire
To Motor Wire
Double pole disconnection switch or 2 pin plug
Wall Switch
E
L
N
Power Supply-Live Wire Brown
Power Supply-Neutral Wire Blue
Ground Wire Yellow /Green
C
2
1
For Light
To Motor Wire
RECEIVER
LED LIGHT
Black Wire
Antenna Wire
For Light
For Light
To Motor Wire
To Motor Wire
Double pole disconnection switch or 2 pin plug
Wall Switch
E
L
N
Power Supply-Live Wire Brown
Power Supply-Neutral Wire Blue
Ground Wire Yellow /Green
C
2
1

INSTALLATION STEPS
1. Remove the two screws from the covering plate on top of the motor housing, then remove the
covering plate.
6
2. Taking one blade at a time, remove the three screws, insert the blade into the slots through the
motor and align the blade with the three holes. Secure the screws through the opening exposed when
the cover plate is removed.
Tighten all screws evenly and securely to ensure quiet, wobble free operation of the fan.
Install all 4 blades in the same fashion, once complete replace the covering plate on top of the motor
housing by reversing step 1.

4. Snuggle the coupling cover down onto the top of the motor housing. CAUTION: DO NOT
remove rubber gasket on top of the coupling cover.
3. Feed the main motor wire plug up through the inside of the downrod, then insert the downrod
into the motor bush. Gently push the cross-pin through the holes aligned with the base of the
motor bush and downrod. CAUTION: DO NOT force the cross-pin, gently wiggle and rotate it
until it glides through both holes. Replace the cotter-pin on the other side of the cross-pin to
secure the downrod to the motor bush. Tighten up both cross screws to make the downrod rigid in
the motor bush.
7

5. Put the canopy through the down rod.
6. Place the hanging ball on top of the down rod and secure it with the ball pin and two screws.
CAUTION: secure one screw through holes on the hanging ball and the downrod.
7. Face slot on hanging ball to the middle of the hanging bracket. Place hanging ball into the bracket.
8

8. Place the receiver on top of the hanger ball and connect the wires.
9. Connect power, receiver and the fan as electrical wiring diagram.
IMPORTANT: The fan must be earthed! Double pole disconnection switch and wall switch must
be connected.
10. Place the canopy over the bracket, align the canopy holes with the screws and tighten.
9
11. Hold the diuser for light model or bottom plate for no light model to the bottom of the
motor and rotate clockwise until it locks into space.
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere Claro Lüfter Handbücher