COBHAM SAILOR 6080 Bedienungsanleitung

SAILOR 6080 Power Supply
Installation manual


i
SAILOR 6080 Power Supply
Installation manual
Document number: 98-129099-E
Release date: January 22, 2018

ii
Disclaimer
Any responsibility or liability for loss or damage in connection with the use of
this product and the accompanying documentation is disclaimed by Thrane &
Thrane A/S. The information in this manual is provided for information
purposes only, is subject to change without notice and may contain errors or
inaccuracies. Manuals issued by Thrane & Thrane A/S are periodically revised
and updated. Anyone relying on this information should acquire the most
current version e.g. from www.cobham.com/satcom, Cobham SYNC
Partner Portal, or from the distributor.Thrane & Thrane A/S is not
responsible for the content or accuracy of any translations or reproductions,
in whole or in part, of this manual from any other source. In the event of any
discrepancies, the English version shall be the governing text.
Thrane & Thrane A/S is trading as Cobham SATCOM.
Copyright
© 2018 Thrane & Thrane A/S. All rights reserved.
Manufacturer address
Thrane & Thrane A/S, Lundtoftegaardsvej 93 D, DK-2800, Kgs. Lyngby,
Denmark.
Disposal
Old electrical and electronic equipment marked with this symbol
can contain substances hazardous to human beings and the
environment. Never dispose these items together with unsorted
municipal waste (household waste). In order to protect the
environment and ensure the correct recycling of old equipment
as well as the re-utilization of individual components, use either
public collection or private collection by the local distributor of old electrical
and electronic equipment marked with this symbol.
Contact the local distributor for information about what type of return system
to use.

iii
Safety summary
The following general safety precautions must be observed during all
phases of operation, service and repair of this equipment. Failure to
comply with these precautions or with specific warnings elsewhere in this
manual violates safety standards of design, manufacture and intended
use of the equipment. Thrane & Thrane A/S assumes no liability for the
customer's failure to comply with these requirements.
GROUND THE EQUIPMENT
To minimise shock hazard, the equipment chassis and cabinet must be
connected to an electrical ground and the cable instructions must be
followed.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the equipment in the presence of flammable gases or
fumes. Operation of any electrical equipment in such an environment
constitutes a definite safety hazard.
KEEP AWAY FROM LIVE CIRCUITS
Operating personnel must not remove equipment covers. Component
replacement and internal adjustment must be made by qualified
maintenance personnel. Do not service the unit with the power cable
connected. Always disconnect and discharge circuits before touching
them.
OBSERVE MARKED AREAS
Under extreme heat conditions do not touch
areas of the unit that are marked with this
symbol, as it may result in injury.
COMPASS SAFE DISTANCE
Minimum safety distance: 30 cm from the unit.
Failure to comply with the rules above will void the warranty!
Warning! Never insert or remove a power supply while its power
switch is in the On (|) position. Make sure the power
switch is Off (O) first.

iv
About the manual
Intended readers
This manual is an installation manual for the SAILOR 6080
Power Supply. It is important that you observe all safety
requirements listed in the beginning of this manual, and operate
the SAILOR 6080 Power Supply according to the instructions
and guidelines in this manual. All installation must be done by
qualified service personnel.
Manual overview
This manual has the following chapters:
•Introduction contains a description of the principle of
operation and uses and features of the power supply.
•Installation contains step-by-step guidelines how to install
the power supply as a stand-alone unit or in a combined
setup and describes the connectors.
•Service and repair contains information on support, how
to return units for repair and instructions how to exchange
the fuses.
•AppendiceswithTechnical specifications, information
about the wall mount tray and wiring 4 or more units.
Typography
In this manual, typography is used as indicated below:
Bold is used to emphasize words and to indicate connector
names of the unit.
Italic is used to emphasize the paragraph title in cross-
references.

v
Table of Contents
Safety summary .......................................................................................iii
About the manual ..................................................................................iv
Chapter 1 Introduction
1.1 General description ...........................................................................1
1.2 Features ....................................................................................................2
1.3 Block diagram .......................................................................................3
1.4 System configuration .....................................................................4
Chapter 2 Installation
2.1 Unpacking................................................................................................5
2.1.1 Optional accessories ............................................................................5
2.2 Installing the SAILOR 6080 Power Supply .......................6
2.2.1 Temperature conditions ....................................................................6
2.2.2 Outline and dimensions .....................................................................7
2.2.3 To install the SAILOR 6080 Power Supply ................................8
2.2.4 Protective lid for the connector panel ........................................9
2.2.5 Inserting the cable in the spring-terminal connector ..........9
2.2.6 Connectors ............................................................................................10
2.3 Installing 2, 3 or 4 SAILOR 6080 units .............................15
2.3.1 Wiring for daisy-chaining ...............................................................17
Chapter 3 Service and repair
3.1 Support, repair and service........................................................19
3.1.1 Contact for support ...........................................................................19
3.1.2 Repair and servicing ..........................................................................19
3.2 Exchanging the fuses ...................................................................20
3.2.1 Exchange the AC fuse ......................................................................20
3.2.2 Exchange the BATTERY fuses ......................................................21
3.3 Returning units for repair ...........................................................21

Table of Contents
vi
3.3.1 Repacking for shipment ..................................................................22
App. A Technical specifications
App. B Wall-mount tray (option)
B.1 Overview................................................................................................25
B.1.1 Dimensions and weight ..................................................................26
App. C Wiring 3 or more SAILOR 6080 units
App. D Declaration of conformity
D.1 CE (LVD & EMC)................................................................................29
Glossary ..................................................................................................................................31
Index ..................................................................................................................................33

1
Chapter 1
1111
Introduction
Introduction 1
1.1 General description
The SAILOR 6080 Power
Supply can deliver 300 W
output power on average with
a peak of 370 W for max.
2minutes(10%duty
cycle).This is useful for MF/HF
applications and DSC
transmissions of short
duration. The SAILOR 6080
Power Supply is AC powered with a battery switch-over function and has an
on/off switch which is lit when the power is turned on.
All connectors are placed at the same end of the power supply to simplify
mounting and installation. The connector panel is protected by a
transparent lid. To secure an installation with heavy cables a cable-relief
bracket can be installed.

Chapter 1: Introduction
2Features
1.2 Features
The SAILOR 6080 Power Supply has the following features:
Two DC connectors, output, range: 28.7 V - 31.2 V
Output power 300 W continuous, 370 W peak (max. 2 min., 10% duty
cycle, 100-240 VAC) or 270 W continuous, 333 W peak (max. 2 min.,
10% duty cycle, 90-100 VAC)
Daisy-chaining of up to four units to give up to 1480 W.1
AC input (100-240 VAC operating) with fuse (6.3 A) with Power Factor
Correction
Automatic detection of input voltage range
AC alarm and Short circuit protection
Over-temperature protection (shutdown with automatic restart)
Switch over to battery power in case of AC supply failure
On/off switch
IP 30 protection
Approval and certification: IEC 60945 approval
1. Output power capability depends on the mounting position (horizontal or
vertical), input voltage, ambient temperature and ventilation at the place of
installation.
Inhaltsverzeichnis
Andere COBHAM Stromversorgung Handbücher