COMPX RegulatoR Bedienungsanleitung

0
RegulatoR
®
, Keyless Locking 1
Instruction Manual

RegulatoR
®
, Keyless Locking 2
Thank you for purchasing the CompX
®
RegulatoR
®
. The RegulatoR is an
innovative solution for locking cabinet doors and drawers. It can mount to
cabinet doors or drawers with a material thickness of 1/32” to 1-7/16”.
Powered by 2-AAA batteries (included), RegulatoR operates using a 4 to 8 digit
code. Operation is simple: type a valid code and press ENTER. Then just turn
the lever to the locked or unlocked position.
RegulatoR is easy to install, and offers:
Programmable user and supervisor codes
Programmable modes of operation
Programmable reset features
RegulatoR is intended for interior use only.
Operating Temperature: 50°F – 120°F (10°C – 48°C)
Note: It is strongly recommended that batteries be replaced on an annual basis.
In the event the batteries should die, they can be replaced via the external battery
compartment.

RegulatoR
®
, Keyless Locking 3
Packaged Components
CompX
®
RegulatoR
®
is offered in two versions: Manual Lock and Self Lock.
Contents will vary depending on the version.
Contents – Manual Lock Version:
Manual RegulatoR Lock Assembly
2 AAA alkaline batteries
1 Offset locking cam / 1 Straight locking cam
FlexaCam adapters
Mounting hardware
Contents – Self Lock Version:
Self Locking RegulatoR Lock assembly featuring SlamCAM
2 AAA alkaline batteries
SlamCAM spacer discs
Mounting hardware
Each lock contains 2 green stickers that are needed for resetting RegulatoR. In
the event RegulatoR needs to be reset, one green sticker is placed on the back of
the device. The remaining green sticker should be saved in a safe and secure
location for future reference. (See page 11 for reset instructions.)
Care and Cleaning
To clean the RegulatoR surface, apply non-acid based cleaner to a clean cotton
cloth; do not spray cleaner directly on the RegulatoR. Wipe down keypad and its
respective housing surfaces of excess cleaner.

RegulatoR
®
, Keyless Locking 4
Table of Contents
Powering Up and Battery Installation ………………………………………….5
Programming Introduction ……………………………………………………..6
Programming Mode …………………………………………………………….9
Changing the User Code ……………………………………………………….10
Changing the Supervisor Code ………………………………………………...11
Single Use/Standard Mode …………………………………………………….12
Single Use Timeout ON/OFF ………………………………………………….13
Security Timeout ON/OFF …………………………………………………….14
Reset User Code ……………………………………………………………….15
Technician Mode ……………………………………………………………....16
User Slot (03-20) Programming ……………………………………………….18
Mounting Template ……………………………………………………………22
Part Number Descriptions ……………………………………………………..23

RegulatoR
®
, Keyless Locking 5
Powering Up and Battery Installation
CompX
®
RegulatoR
®
is shipped with two AAA batteries. While RegulatoR
features a low battery indicator, annual battery replacement is recommended.
Mixing batteries of different chemistries could damage the RegulatoR resulting
in lock failure.
To power up RegulatoR, remove the red tag. Lock is now ready for use.
A T-15 pin in head Torx
®
(6-lobe) will be required to remove the battery cover.
(Not Included)
To change batteries:
1. Loosen the retaining
screw.
2. Remove battery cover.
3. Press CLEAR 5 times.
4. Insert new batteries as
shown in the illustration.
5. Reinstall battery cover,
tighten retaining screw.

RegulatoR
®
, Keyless Locking 6
Programming – Introduction
CompX
®
RegulatoR
®
is easy to program and operate. Type the user code
(factory default 1234) and press ENTER to lock or unlock the cabinet.
The supervisor can change operating codes, modes and restore lock settings.
While RegulatoR is easy to program, we highly recommend reading the
complete programming instructions prior to making any changes. Remember to
keep track of any programming changes.
Button locations, indicator lights and knob referenced in the programming
instructions are shown below.
CLEAR button erases any key input made in error
Indicator Lights
Green – Indicates button
input and valid code
Yellow - Indicates low
battery or program mode.
Red – Indicates incorrect
entry
Knob is always rotated
clockwise to unlock ENTER button is used to complete code
and counter clockwise to lock and begin programming

RegulatoR
®
, Keyless Locking 7
CompX
®
RegulatoR
®
is offered with Self Lock featuring SlamCAM. If your
lock is the Self Lock version, follow the directions below to unlock and lock the
RegulatoR:
To operate the standard Self Lock version of
RegulatoR:
Type a valid code, press ENTER and rotate knob
clockwise 90°, hold knob until door or drawer is
open. Release knob, RegulatoR knob will return
to the locked position. Door or drawer can be
closed at any time.

RegulatoR
®
, Keyless Locking 8
CompX
®
RegulatoR
®
is offered in a Manual Lock version. If your lock is the
Manual Lock version follow the directions below to unlock and lock the
RegulatoR.
To operate the standard Manual Lock
version of RegulatoR:
To unlock, type a valid code, press
ENTER and rotate knob clockwise 90°.
To lock, rotate knob 90° counter
clockwise.

RegulatoR
®
, Keyless Locking 9
RegulatoR Programming Mode
To enter programming mode you must know the supervisor code. The default
supervisor code is 12345. Once in programming mode, multiple changes can be
made prior to exiting programming.
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Lock must be in the locked position prior to entering programming
mode.
2. Type supervisor code and press ENTER.
Rotate the knob to the unlocked position and press and hold ENTER
for 3seconds (yellow indicator light will illuminate).
•If product is Self Lock with the SlamCAM feature you can
now let go of the knob.
3. With the yellow indicator light illuminated, programming can begin.

RegulatoR
®
, Keyless Locking 10
Changing the User Code
To change the user code, follow the steps on page 9to enter programming mode.
The factory default user code is 1234 (User codes must be 4 to 8 digits in
length.)
There is a 10 second programming time limit between each step. If RegulatoR
times out or an error is made, programming will end and you will need to enter
programming mode again.
1. Place RegulatoR into programming mode (see page 9).
2. Press 1and then press ENTER.
3. Type the current user code and press ENTER.
4. Type the new user code and press ENTER.
5. Retype the new user code and press ENTER.
6. If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9and then ENTER to exit programming.
Andere Handbücher für RegulatoR
1
Inhaltsverzeichnis

















