CyberPower RMCARD205 Bedienungsanleitung

Copyright © 2017 Cyber Power Systems, Inc. All rights reserved.
QUICK START GUIDE
Remote Management CardRemote Management Card
RMCARD205
RMCARD305
SAVE THESE INSTRUCTIONS
Please read this guide and follow the instructions for installation and use.
K01-0000449-02
Tx/Rx
Link
Universal
RMCARD205
CyberPower
RMCARD305
Tx/Rx
Link
Universal
CyberPower

Table of Contenets
INTRODUCTION.......................................................... 1
Overview ............................................................................ 1
System Requirements ................................................... 1
Unpacking.......................................................................... 1
Front Panel .........................................................................2
LED Status Indicator.......................................................2
INSTALLATION ...........................................................3
Step 1. Hardware Installation .................................... 3
Step 2. Configure the IP Address ............................ 4
WEB INTERFACE ........................................................6
Login User Account ...................................................... 6
FIRMWARE UPGRADE ...............................................6
Using Upgrade and Configuration Utility Tool ....7
RESET TO FACTORY DEFAULT SETTING/
RECOVER FROM A LOST PASSWORD .................10
RMCARD ADAPTER GUIDE ..................................... 11
SOFTWARE SUPPORT ............................................. 13
TROUBLESHOOTING ............................................... 14
CONFORMANCE APPROVALS ............................... 15
i

1
INTRODUCTION
Overview
The CyberPower Remote Management Card allows a UPS/ATS
PDU system and environmental sensor to be managed, monitored,
and configured. After installing the hardware and configuring an IP
address, the user can access, monitor, and control the UPS/ATS
PDU from anywhere in the world! Simply use a web browser or SSH
client to access your UPS/ATS PDU. Servers and workstations can
be protected by the UPS utilizing PowerPanel® Business Edition
Client to gracefully shutdown when signaled by the Remote
Management Card.
System Requirements
● A 10/100Mbps Ethernet connection to an existing network
● Web Browser or SSH client
● (Optional) NMS (Network Management System) compliant with
SNMP
Unpacking
Inspect the Remote Management Card upon receipt. The package
should contain the following:
● CyberPower Remote Management Card
● RJ45/DB9 Serial Port Connection Cable
● Quick Start Guide
● Spare Jumper
● RMCARD205 Front Panel (with RMCARD305 only)

LED Status Indicators
Link LED
O
On (Yellow)
Tx/Rx LED
O
On (Green)
Flashing (Green)
Condition
The Remote Management Card is not
connected to the Network / or the Remote
Management Card power is o
The Remote Management Card is
connected to the Network
The Remote Management Card power is o
The Remote Management Card power is on
- Receiving/transmitting data packet
- Reset finished
1 2
4
3
1
3
1. Universal Port
2. Ethernet Port
3. Tx/Rx Indicator
4. Link Indicator
RMCARD205
RMCARD305
2
Universal
RMCARD205
Link Tx/Rx
Universal Link Tx/Rx
RMCARD305
Front Panel
2
4

INSTALLATION
5. (Optional) To connect an
environmental sensor, use a
RJ45 Ethernet cable. Connect
one end to the Universal port
on the RMCARD and the other
end into the sensor. For more
information, please see the
ENVIROSENOR user’s manual.
NOTE: The CyberPower Remote Management Card is hot-swappable, so you
do not need to turn o the device to install it.
4. Connect an Ethernet cable to
the Ethernet port of the
CyberPower Remote
Management Card.
3. Insert and tighten the
retaining screws.
2. Install the CyberPower
Remote Management Card
into the expansion slot.
1. Remove the two retaining
screws of the expansion
slot, and then remove the
cover.
Step 1. Hardware Installation
RMCARD205 RMCARD305
3
RMCARD305
Tx/Rx
Universal
CyberPower
2
R0
C
RMAD5
Universal
x
Tx/R
CyberPower
ARD205
salTx/Rx
CyberPower
Tx/Rx
sal
RMCARD305
CyberPower
2
R0
C
RMAD5
Universal
Linkx
Tx/R
CyberPower
RMCARD305
Tx/Rx
Link
Universal
CyberPower

Figure 1. The main window of the “Power Device Network Utility” program
4. Select the Remote Management Card you are setting up. Click
on the Tools menu and select “Device Setup” or double click
the Remote Management Card you want to configure.
5. You can modify the IP
Address, Subnet Mask, and
Gateway address for the
Device MAC Address listed in
the Device Network Settings
window, as shown in Figure
2. The factory default IP
Address is 192.168.20.177
and the default Subnet Mask
is 255.255.255.0.
6. Modify the IP, subnet mask or
gateway address. Enter the
new addresses into the
corresponding fields and then
click “Save”.
Figure 2. The Device Network setting window
4
Step 2. Configure the IP Address for the CyberPower
Remote Management Card
Method 1: Using the Power Device Network Utility
1. Install the Power Device Network Utility available for
download at www.CyberPower.com.
2. After installation completes, run the “Power Device Network
Utility”.
3. The main window of the Power Device Network Utility
program is shown in Figure 1. The configuration tool will
display all CyberPower Remote Management devices present
on the local network subnet. The "Refresh" button is used to
search the local network subnet again.

Method 2: Using a Command Prompt
NOTE: These instructions are for Windows OS. For other OS please refer
to RMCARD User’s Manual available for download at CyberPower
Systems ocal website: www.CyberPower.com.
1. Obtain the MAC address from the label on the Remote
Management Card. Each Management Card has a unique MAC
address.
2. Use the ARP command to set the IP address.
Example:
To assign the IP Address 192.168.10.134 for the Remote
Management Card, which has a MAC address of
00-0C-15-00-FF-99 you will type in the following in the
command prompt from a PC connected to the same network
as the Remote Management Card.
(1) Type in “arp -s192.168.10.134 00-0C-15-00-FF-99”then
press Enter.
3. Use the Ping command to assign a size of 123 bytes to the IP.
(1) Type in “ping 192.168.10.134 -l 123”then press Enter.
(2) If the replies are received, your computer can
communicate with the IP address.
7. You will need to enter a User
Name and Password for the
Remote Management Card in
the authentication window, as
shown in Figure 3.
- Default user name: cyber
- Default password: cyber
8. If the IP address change is
successful, you will see a
message confirming the IP set
up, as shown in Figure 4.
Figure 3. Authentication window
Figure 4. Setup IP Address successfully message
5

WEB INTERFACE
Login User Account
You will need to enter a User Name and Password to login to the
interface, and can select a preferred language after login. There are
two user account types.
1. Administrator
- Default username: cyber
- Default password: cyber
2. View only
- Default username: device
- Default password: cyber
You will be asked to reset a username and password upon the first
login. The administrator can access all functions, including
enable/disable the view only account. The viewer can access read
only features but cannot change any settings. For detailed
descriptions and explanations of the Web UI, please refer to
RMCARD User’s Manual.
FIRMWARE UPGRADE
By upgrading the firmware, you can obtain both the new features
and updates/improvements to existing functionality. To ensure the
RMCARD firmware is kept up to date, please visit our website
every 3 months to see if there is any updated firmware version
available. You can check the “Firmware version” on the
[System->About] page on the web user interface of the RMCARD.
There are two files to update in order to upgrade the firmware
version.
- A. cpsrm2scfw_XXX.bin
- B. cpsrm2scdata_XXX.bin
NOTE: Please do not turn the UPS/ATS PDU o when processing the
Firmware upgrade.
6

Using Upgrade and Configuration Utility Tool
(Bulk Firmware Upgrade Tool)
1. Install the CyberPower Upgrade and Configuration Utility tool
available for download at www.CyberPower.com.
2. After installation completes, run the “Upgrade and Configuration
Utility”.
3. The main window of the Upgrade and Configuration Utility tool
program is shown in Figure 5. The configuration tool will display
all CyberPower Remote Management devices present on the
local network subnet. The "Discover" button is used to search
the local network subnet again.
NOTE: You can click “View” to select the items you want to view.
Figure 5. The main window of the “Upgrade and Configuration Utility” program
4. Check the boxes to select the devices you wish to upgrade, and
select “Update” on the right to update the device user account
and password. Once the update is confirmed, the status icon
next to the IP Address will change from orange to green.
NOTE: You must update the device user account and password credentials
before firmware upgrade.
7

5. Select the devices you wish to upgrade by checking their
respective checkbox and select “Upgrade Firmware”.
NOTE: You can upgrade the firmware of multiple devices that use the same
firmware files (Bulk firmware upgrade).
6. Select the Firmware and Data files and click “OK”, as shown in
Figure 6.
Figure 7. Confirm Upgrade Firmware message window
Figure 6. The File Locations of Firmware & Data window
7. Click “Yes” to start firmware upgrade on selected devices, as
shown in Figure 7.
8
Andere Handbücher für RMCARD205
4
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere CyberPower Netzwerk-Hardware Handbücher
Beliebte Netzwerk-Hardware Handbücher anderer Marken

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Bedienungsanleitung

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Bedienungsanleitung

Yudor
Yudor YDS-16 Bedienungsanleitung

D-Link
D-Link ShareCenter DNS-320L Bedienungsanleitung

Samsung
Samsung ES1642dc Gebrauchsanweisung

Honeywell Home
Honeywell Home LTEM-PV Montageanleitung