Datalogic Controller SC6000 Bedienungsanleitung

SC6000 CONTROLLER
QUICK REFERENCE GUIDE
821001135 (Rev. F)

SC6000 QUICK GUIDE
2
UPDATES AND LANGUAGE AVAILABILITY
UK/US The latest drivers and documentation updates for this product are available on Internet.
Log on to: www.automation.datalogic.com
ISu Internet sono disponibili le versioni aggiornate di driver e documentazione di questo
prodotto. Questo manuale è disponibile anche nella versione italiana.
Collegarsi a: www.automation.datalogic.com
FLes versions mises à jour de drivers et documentation de ce produit sont disponibles sur
Internet. Ce manuel est aussi disponible en version française.
Cliquez sur : www.automation.datalogic.com
DIm Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem
Produkt. Die deutschsprachige Version dieses Handbuches ist auch verfügbar.
Adresse : www.automation.datalogic.com
EEn Internet están disponibles las versiones actualizadas de los drivers y documentación de
este producto. También está disponible la versión en español de este manual.
Dirección Internet : www.automation.datalogic.com
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its website. Log on to
www.automation.datalogic.com and click on the links indicated for further information:
PRODUCTS
Search through the links to arrive at your product page which describes specific Info, Features, Applications,
Models, Accessories, and Downloads including the Genius™ utility program, which allows device
configuration using a PC. It provides RS232 and Ethernet interface configuration.
SERVICE
- Overview - Warranty Extensions and Maintenance Agreements
- Sales Network-Listing of Subsidiaries, Repair Centers, Partners
- Helpdesk
- Material Return Authorization
LEGAL NOTICES
© 2003 - 2010 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest extent under
U.S. and international laws. Copying, or altering of this document is prohibited without express written consent
from Datalogic Automation S.r.l.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the
U.S.A. and the E.U.
Genius, PackTrack and DARP are trademarks of Datalogic Automation S.r.l. All other brand and product names
mentioned herein are for identification purposes only and may be trademarks or registered trademarks of their
respective owners.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or
consequential damages resulting from the use of this material.

SC6000 QUICK GUIDE
3
GENERAL VIEW
Figure A
Connector Panel1
Figure B
Power ON and Communication LEDs
1
Status LEDs
3
LCD Display
2
Programming Keypad
4
Connector Panel Legend5
SC6000-1200 Standard Model
Figure C
Modem Connector
1
Power/Net Connector
2
Main Interface Connector
3
Ethernet Connector
4
Extended I/O Connector
5
A
uxiliary Interface Connector
6
3
4
2
1
5
1
234
56
1

SC6000 QUICK GUIDE
4
SC6000-1211 Profibus Model
Figure D
Modem Connector
1
Power/Net Connector
2
Main Interface Connector
3
Ethernet Connector
4
Extended I/O Connector
5
A
uxiliary Interface Connector
6
Profibus Connector
7
SC6000-1215 DeviceNet Model
Figure E
Modem Connector
1
Power/Net Connector
2
Main Interface Connector
3
Ethernet Connector
4
Extended I/O Connector
5
A
uxiliary Interface Connecto
r
6
DeviceNet Connecto
r
7
SC6000-1230 Dual Ethernet Model
Figure F
Modem Connector
1
Power/Net Connector
2
Main Interface Connector
3
Ethernet Connector
4
Extended I/O Connector
5
A
uxiliary Interface Connector
6
Second Ethernet Connecto
r
7
234
56
1
7
234
56
1
7
234
56
1
7

SC6000 QUICK GUIDE
5
NOTE
For further details on product installation, see the complete Reference Manual available on
the configuration CD-ROM included with this product.
ELECTRICAL CONNECTIONS
The SC6000 is designed to easily connect to the PWO power supply through two standard accessory cables. All
system cabling is concentrated at the PWO except for some Host connections and the Auxiliary interface for
SC6000 configuration using a laptop PC.
The following connector pinouts are given for reference.
MAIN INTERFACE
Pin RS232 RS485 Full Duplex
2 TX TX485 +
3 RX RX485 +
5 GND_ISO GND_ISO
7 CTS RX485 -
8 RTS TX485 -
51
96
9-pin D-sub Female Connector
CAUTION
Do not connect GND and GND_ISO to different (external) ground references. GND and
GND_ISO are internally connected through filtering circuitry which can be permanently
damaged if subjected to voltage drops over 0.8 Vdc.
AUXILIARY INTERFACE
Pin Name Function
2 TX Transmit
3 RX Receive
5 GND Ground
51
96
9-pin D-sub Female Connector
MODEM CONNECTOR
Pin Name Function
1 CD Carrier detect
2 RX Receive
3 TX Transmit
4 DTR Data terminal ready
5 GND Ground
6 DSR Data set ready
7 RTS Request to send
8 CTS Clear to send
9 RI Ring indicator
15
69
9-pin D-sub Male Connector

SC6000 QUICK GUIDE
6
ETHERNET CONNECTOR
Pin Name Function
1 TX + Transmitted data (+)
2 TX - Transmitted data (-)
3 RX + Received data (+)
6 RX - Received data (-)
4, 5, 7, 8 N.C. Not connected
1 8
Harting RJ Industrial Female Connector
NOTE
For Ethernet connections, always use the Harting RJ Industrial® Push Pull Ethernet
connector (included in the package). This connector assures a robust connection and full IP
rated protection.
PROFIBUS CONNECTOR
Pin Name Function
1 Shield* Shield, protective ground resp.
2 N.C. Not connected
3 B-LINE (RxD/TxD-P) Received/Transmitted data-P
4 CNTR-P** Repeater control signal
5 DGND Data ground (M5V)
6 +5 V Voltage plus (P5V)
7 N.C. Not connected
8 A-LINE (RxD/TxD-N) Received/Transmitted data
9 CNTR-N** Repeater control signal
51
96
9-pin D-sub Female Connector
* signal is optional
** signal is optional; RS485 level
DEVICENET CONNECTOR
Pin Name Function
2 V+ Supply voltage – positive pin
5 CAN_L CAN bus data line – L
1 SHIELD Shield
4 CAN_H CAN bus data line – H
3 V- Supply voltage – negative pin
1
3
2
4
5
5-
p
in male DeviceNet Connector

SC6000 QUICK GUIDE
7
TYPICAL LAYOUTS
Ethernet Connection
Main Connection
Modem Connection
CAB-SC6003
Extended I/O
SC6000
CAB-SC6013
Power/Net
NULL-MODEM
Cable
ETHERNET
VAC INPUT
PWO
A
U
X
HUB
Host
CAB-SC6003
Extended I/O
SC6000
Main
CAB-SC6103
NULL-MODEM
Cable
ETHERNET
VAC INPUT
PWO
A
U
X
HUB
Host
Main
CAB-SC6013
Power/Net
CAB-SC6003
Extended I/O
SC6000
Power/Net
CAB-SC6013
NULL-MODEM
Cable
ETHERNET
VAC INPUT
PWO
A
U
X
HUB
to Remote Host
Telephone line
CAB-SC6103
Modem

SC6000 QUICK GUIDE
8
Fieldbus Network
Dual Ethernet Connection
CAB-SC6003
Extended I/O
SC6000
CAB-SC6013
Power/Net
NULL-MODEM
Cable
FIELDBUS
VAC INPUT
PWO
A
U
X
Host PLC
CAB-SC6003
Extended I/O
SC6000
CAB-SC6013
Power/Net
NULL-MODEM
Cable
ETHERNET
VAC INPUT
PWO
A
U
X
HUB
Host 1
ETHERNET
HUB
Host 2

SC6000 QUICK GUIDE
9
APPENDIX
MECHANICAL DIMENSIONS
319.5
[12.58]
248.7
[9.79]
80.2
[3.16]
99.7
[3.93]
124.4
[4.90]
39.7
[1.56]
MØ8
39.7
[1.56]
124.4
[4.90]
298
[11.73]
SC6000 Overall Dimensions
180
[7.09]
309
[12.17]
5
[0.20]
N°2R15
[R0.59]
15
[0.59]
50
[1.97]
48
[1.89]
N°6 8
[0.32]
80
[3.15]
95
[3.74]
40
[1.57]
85
[3.35]
50
[1.97]
85
[3.35]
48
[1.89]
300
[11.80]
40
[1.57]
40
[1.57]
8
[0.33]
N°2R10
[R0.39]
N°2Ø56
[Ø2.22]
M8
16
[0.63]
16
[0.63]
30
[1.18]
15
[0.59]
N°2Ø8
[Ø0.33]
20
[0.79]
ST-222 Bracket Overall Dimensions
mm
inch
mm
inch

SC6000 QUICK GUIDE
10
MECHANICAL INSTALLATION
To mount the SC6000 Controller on the reading station frame proceed as follows:
1 Mount the bracket on the reading station frame: the slots on the bracket will help obtain the best positioning.
When working in environments characterized by strong vibrations, set the screws as close as possible to the
bracket edges, see the figure below.
2 Tighten the ST-222 bracket to the reading station frame using the screws and washers.
Mounting the bracket on the conveyor
3 Position the SC6000 Controller at the top of the bracket: make sure the two large round openings coincide to
the ones located at the edges of the SC6000 Controller.
4 While supporting the SC6000 Controller, rotate the whole device until it is aligned for the best viewing
position, then insert the set pin screw with locking washer until it inserts into one of the small positioning
holes located on the terminal bracket.
SC6000 Controller Side View with Punched Steel Ring and Relative Set Pin Screw
The specially punched steel ring has been designed to obtain the most precise rotation possible in terms of
angle calibration, steadiness and consequent absence of torque between both sides of device.
Set pin screw
Andere Handbücher für Controller SC6000
4
Inhaltsverzeichnis
Andere Datalogic Controller Handbücher

Datalogic
Datalogic Controller SC6000 Bedienungsanleitung

Datalogic
Datalogic VS Series Bedienungsanleitung

Datalogic
Datalogic Controller SC6000 Bedienungsanleitung

Datalogic
Datalogic SC4000 Bedienungsanleitung

Datalogic
Datalogic COBALT C0405-USB-01 Bedienungsanleitung

Datalogic
Datalogic DX8200 Bedienungsanleitung

Datalogic
Datalogic HF-CNTL-IND-02 Bedienungsanleitung

Datalogic
Datalogic Controller SC6000 Bedienungsanleitung