PMT2 Panel Mount Power
Supply
PMT2 75 W series
/ PMT-
□
□□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
www.DeltaPSU.com (July 2022, Rev. 07)
Safety Standards / Directives
Safety Entry Low Voltage SELV
Electrical Safety TUV Bauart
UL/cUL
CB scheme
KC
EAC
EN 62368-1, EN 60335-1, EN 61558-1/-2-16
UL 62368-1, and CAN/CSA C22.2 No. 62368-1
IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16
K 60950-1
TP TC 004/2011
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive
2014/35/EU
UKCA In conformance with Electromagnetic Compatibility Regulations 2016 and
Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation Input to Output 4.0 KVac
Input to Ground 2.0 KVac
Output to Ground 1.25 KVac
EMC
Emissions (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS
CISPR32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN
Immunity EN/BS EN 55035, KN 35, EN/BS EN 61000-6-2
Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1
Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1)
Air Discharge: 15 kV
Contact Discharge: 8 kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A1)
80 MHz – 1 GHz, 10 V/M with 1 kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1)
Surge IEC 61000-4-5 Level 4 Criteria A1)
Common Mode4): 4 kV
Differential Mode5): 2 kV
Conducted IEC 61000-4-6 Level 3 Criteria A1)
150 kHz – 80 MHz, 10 Vrms
Power Frequency Magnetic Fields IEC 61000-4-8 Level 4 Criteria A1)
Voltage Dips and Interruptions IEC 61000-4-11 0% residual; 1 cycle, Criteria B
40% residual; 10 cycle, Criteria C3)
70% residual; 25 cycle, Criteria C
3)
Harmonic Current Emission
IEC/EN/BS EN
61000-3-2
Voltage Sag Immunity SEMI F47 –
0706
80% of 200 Vac
70% of 200 Vac
50% of 200 Vac
160 Vac, 1000 ms
140 Vac, 500 ms
100 Vac, 200 ms
Criteria A1)
Criteria A1)
Criteria A1)
1) Criteria A: Normal performance within the specification limits
2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test.
3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test)
4) Asymmetrical: Common mode (Line to earth)
5) Symmetrical: Differential mode (Line to line)