PMT2 Panel Mount Power
Supply
PMT2 150 W series
/ PMT-
□
□□
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
www.DeltaPSU.com (April 2023, Rev. 12)
Reliability Data
MTBF > 700,000 hrs as per Telcordia SR-332
I/P: 230Vac, O/P: 100% Load, Ta: 25°C)
Expected Cap Life Time 10 years (230Vac, 50% load @ 40°C)
Safety Standards / Directives
Safety Entry Low Voltage SELV
Electrical Safety TUV Bauart
cULus
CB scheme
CCC
KC
EAC
EN 62368-1, EN60335-1, EN 61558-1/-2-16
UL 62368-1, and CAN/CSA C22.2 No. 62368-1
IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16
GB 4943.1
K 60950-1
TP TC 004/2011
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive
2014/35/EU
UKCA In conformance with Electromagnetic Compatibility Regulations 2016 and
Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation Input to Output 4.0 KVac
Input to Ground 2.0 KVac
Output to Ground 1.25 KVac
EMC
Emissions (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS
CISPR32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN
61000-6-3 : Class B
Immunity EN/BS EN 55035, KN35, EN/BS EN 61000-6-2
Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1
Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1)
Air Discharge: 15 kV
Contact Discharge: 8 kV
Radiated Field IEC 61000-4-3 Level 3 Criteria A1)
80 MHz – 1 GHz, 10 V/M with 1 kHz tone / 80% modulation
Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1)
Surge IEC 61000-4-5 Level 4 Criteria A1)
Common Mode4): 4 kV
Differential Mode5): 2 kV
Conducted IEC 61000-4-6 Level 3 Criteria A1)
150 kHz – 80 MHz, 10 Vrms
Power Frequency Magnetic Fields IEC 61000-4-8 Level 4 Criteria A1)
30 A/Meter
Voltage Dips and Interruptions IEC 61000-4-11 0% residual; 1 cycle, Criteria B
40% residual; 10 cycle, Criteria C3)
70% residual; 25 cycle, Criteria C
3)
Harmonic Current Emission IEC/EN/BS EN
Class A
1) Criteria A: Normal performance within the specification limits
2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test.
3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test)
4) Asymmetrical: Common mode (Line to earth)
5) Symmetrical: Differential mode (Line to line)