DEVI DEVIreg 535 Bedienungsanleitung

DeviregTM 535
Installation manual
Warning!
This manual is only to be used by a
professional installer to install and
set up the thermostat properly.
It is not intended for the end-user!
INT

2
... your DEVI floor heating system
Your property has been installed with a DEVI electric floor
heating system. DEVI is Europe’s leading floor heating manu-
facturer, with over 45 years experience. We are confident that
you will be satisfied with your new system.
DEVI brings you…
An Invisible heating solution - A concealed heat source opens
up greater opportunities for decorating and furnishing.
Optimum comfort - DEVI brings you the luxury and comfort
of a warm floor as well as a pleasant room temperature.
Floor heating is the most comfortable type of heating
because it is based on the fact that warmth travels upwards;
pleasant warmth for your feet, body and head.
Low running costs – Thanks to the precise DEVI thermostat
and the placement of the heating elements right under the
floor surface the heat can be controlled optimally in order for
you to have the comfort you desire with minimal energy use.
Moreover electric floor heating is practically maintenance
free, in total keeping down the running costs.
A long lasting solution - We back-up our floor heating solu-
tions with a ten year guarantee on all our mats and cables,
and a two year warranty on our thermostats. Practically
speaking you can count on DEVI heating cables and mats
lasting as long as the house in which they are installed – and
that is without having to maintain them.
Hygiene - As DEVI produce floor heating systems, only very
gentle air is circulating, and the amount of travelling dust
particles is reduced considerably; a great relief for people
with allergies or asthma. There are also no dangerous fumes
such as carbon monoxide generated by the system.
Congratulations with…

INT
3
Table of content
Table of content
Install & configure the thermostat . . . . . . . . . . . . . . . . . . . . . .4
Placement of DeviregTM 535 ........................4
Installation of DeviregTM 535 .......................5
User’s guide to DeviregTM 535 . . . . . . . . . . . . . . . . . . . . . . . . 10
Introduction .................................... 10
Display, icons and buttons . . . . . . . . . . . . . . . . . . . . . . . 10
Increase / decrease preferred temperature. ....... 11
Using the timer function ......................... 12
Settings ......................................... 14
Setting the time .............................. 16
Setting the weekday.......................... 17
Setting the timer periods ..................... 18
Setting the comfort temperature ............. 19
Setting the savings temperature .............. 19
Setting the minimum floor temperature limit.. 19
Special features.................................. 20
Childproof mode ............................. 20
Frost protection mode........................ 20
OFF mode.................................... 21
Restore timer default settings................. 21
Switching displayed temperature ............. 22
Trouble shooting ................................ 23
Technical Specifications ............................. 24
Disposal Instruction.................................. 25
The DEVITM Guarantee ............................... 26

4
Placement of DeviregTM 535
When DeviregTM 535 is used as a room
sensor, installation height should typically be
between 80-150 cm.
At least 50 cm away from windows/doors that
will be left open occasionally.
In wet rooms it should be installed on an even
surface, according to local building regula-
tions.
Not on a wall where it will be subjected to
direct sunlight.
Not on the inner side of a wall facing the
outside.
Install & configure the thermostat

INT
5
N L
Installation of DeviregTM 535
1. To remove the front cover, gently press the release tabs
under the bottom of the thermostat with a screwdriver.
Then remove the front.
2. Connect the thermostat according to the connection
diagram
The screen of the heating cable must be connected via a
terminal strip to the earth wire of the supply cable.
Installation and connection
Max.
Load
15 A
Sensor
NO
CONNECT
Mains
180-250V~
Removing the front cover and
pushing the installation button,
is not intended to be done by
anyone else but a qualified
installer!
NL NTC
L
Load
N
Load

6
3. Choose sensor combination
When installing the Devireg™ 535 you need to choose
the type of heating and thus which sensors should be
used. You have three options:
Comfort heating: Constant temperature on the floor in
bathrooms and other rooms where a comfortable warm
surface is required.
Install the Floor sensor and choose only the Floor sensor.
Total heating: Control of room temperature in living
rooms etc. Install the Floor sensor and choose both
Floor sensor and Room sensor.
No floor sensor: A floor sensor is not present, and
cannot be installed. Choose Room sensor. (Not
recommended).
Be aware that without a floor sensor, the temperature
control can be less accurate, and overheating of the
floor is of higher risk.
DEVI recommends that a floor sensor is always
installed.
When the thermostat is used to control a floor heating
element according to EN/IEC 60335-1 and
EN/IEC 60335-2-96, always use the floor sensor
and never set the temperature limit above 35°C.
Choose sensor combination

INT
7
Selection of sensor type
Power on the thermostat.
With the front off, with a small screw-
driver, pencil, or needle press the
installation button.
Select the sensors to be used for the
heating system:
DeviregTM 535 is able to use two
sensors:
- a built-in room sensor
- an external sensor to be placed
in the floor.
This gives 3 options:
floor sensor.
room sensor.
both room and floor sensor.
The default is
To change this setting, press •and
use the arrow buttons ▲▼ to select
your choice. Press •to accept your
choice.
If you have selected room sensor
only, the installation procedure is
complete. Press installation button
to accept. (Go to page 9).
If you have selected floor sensor or a
combination of room- and floor sen-
sor press ▲▼ for the next setting.
Configuration - sensor
Always use floor sensor or a room
+ floor sensor combination when
used to control floor heating

8
Notice:
The floor temperature is measured where the sensor is
placed. The temperature of the bottom of a wooden floor
can be up to 10 degrees higher than the top. Floor manu-
factures often specify the max. temperature on the top
surface of the floor.
Please contact your floor supplier for maximum surface
temperature.
Maximum floor temperature.
When selecting either floor
sensor or floor and room
sensors, next screen is maximum
floor temperature.
Default setting is 35°C.
To change this setting, press •and
use the arrow buttons ▲▼ to select
your choice. Press •to accept your
choice.
If you have selected a combination of
room and floor sensor, the installa-
tion procedure is complete.
Press installation button to accept.
(Go to page 9)
If you have selected floor sensor only
press ▲▼ for the next setting.
Configuration - Max. floor temp.
When the thermostat is used to control a floor heating
element according to EN/IEC 60335-1 and
EN/IEC 60335-2-96, always use the floor sensor
and never set the temperature limit above 35°C.

INT
9
Scale
If you select DeviregTM 535 to only
use a floor sensor, mode , you
have to select the display type. The
choice is either numerical scale 1-6
or Celcius scale 5° to 45°.
Default is Celcius scale. When select-
ing Celcius, the display will show
the actual temperature at the floor
sensor.
To change this setting, press •and
use the arrow buttons ▲▼ to select
your choice.
Press •to accept your choice.
The installation procedure is now
finished.
You can use the ▲▼ for going back or
forward through the settings.
Otherwise:
Press the installation pinhole to exit
installation mode.
4. Put the frame and front back on.
Initially mains supply the thermostat for 15 hours to
fully charge the battery. The current time and day
is then kept for 80 days if mains supply is off.
All other settings are stored permanently.
Configuration - Scale

10
DeviregTM 535 is an electronic timer temperature controller,
specially designed for floor heating systems.
The DeviregTM 535, once set, automatically adjusts the
heating to meet your comfort levels, regardless of changing
weather conditions by measuring the floor temperature and
combining it with the air temperature.
Even the programming of economy temperatures (i.e. lower-
ing of temperature during the night and when you are out
of the house) is very simple. Just tell the DeviregTM 535 your
daily rhythm and choose your program.
It also features a minimum floor temp. setting, eg. for
keeping your tile floors warm in summer as well.
DeviregTM 535 Introduction
This is the standard display. The
currently measured temperature is
shown.
is shown to symbolize that current
temperature is displayed, i.e. unit
working as a thermometer.
The thermostat is operated with the
3 buttons below the display.
▼down
▲up
• select
Two pinhole buttons are available for
dedicated features
Childproof. Locks all buttons.
Settings.
Display, icons and buttons
This is a safety
switch, meaing all
electrical supply to
the thermostat is
disconnected when
turned off.
User’s guide to DeviregTM 535
Andere Handbücher für DEVIreg 535
6
Inhaltsverzeichnis
Andere DEVI Fußbodenheizungssystem Handbücher
Beliebte Fußbodenheizungssystem Handbücher anderer Marken

Powerblanket
Powerblanket Summerstep series Bedienungsanleitung

Flextherm
Flextherm FLP35-120GA Bedienungsanleitung

Flextherm
Flextherm GreenCable Mat Series Bedienungsanleitung

Penrod
Penrod Warmset Bedienungsanleitung

HandyHeat
HandyHeat Carbon Film Bedienungsanleitung

Elements
Elements eRibbon Bedienungsanleitung