Digitroll DMS 08 LCD Bedienungsanleitung

2019. 09. 10. – rev. C
DMS 08 LCD
(version 1.x)
DMS 08 LCD
seeding control system for
PLANTERS
USER’S MANUAL
DIGITROLL

SYSTEM DRAFT
2
SYSTEM DRAFT
Seeding control system for planters 1-8 rows with area counter
DS 1000 -custom designed for seeder type, placed in seed tube
DS 2000 - custom designed for seeder type, placed in coulter
RED
BLUE

3
CONTENT
SYSTEM DRAFT ........................................................................................................... 2
GENERAL DESCRIPTION ........................................................................................... 4
MOUNTING ................................................................................................................... 5
MONITOR FRONT ........................................................................................................ 6
SWITCH ON ................................................................................................................... 6
SYSTEM TEST .............................................................................................................. 7
MENU ............................................................................................................................. 8
SEEDING CONTROL .................................................................................................... 9
SETTING BASIC DATA ............................................................................................. 10
TROUBLESHOOTING ................................................................................................ 12
MAINTENANCE, STORAGE ..................................................................................... 15
WARRANTY PROVIDED .......................................................................................... 15
MISSING SEED TIME/SPEED/SEED SPACING TABLE ........................................ 16

GENERAL DESCRIPTION
4
GENERAL DESCRIPTION
DMS 08 LCD MONITOR
· illuminated LCD display
· massive aluminium housing
· audible and visual alarms
· 5 selectable languages
· nonvolatile memory for safe storage of measured and adjusted data
· auto off
SYSTEM CONSTRUCTION
· infrared sensation
· connected in linear string system up to 8 rows
· modules are exchangeable, their sequence is determined automatically
when connected
· harness-free network - easy cabling and mounting
SYSTEM TEST
Sensordiagnostics.
· automatic recognition and readiness test of photosensors
· dusty or blockaged sensor display
SEEDING CONTROL
· Simultaneously detected seeding continuity on all rows
· Selectable seed dize and shape
· Adjustable missing seed time interval for error signal
· Easy to use seeding blockage control mode. Unnecessary any settings.
HECTARE COUNTING
· Measure and store total and partial seeded area to 999,99 ha
· Start/stop measuring by signal of photosensors
SYMBOLS APPLIED
*
Seed
C
Recognized photosensor
O
Dusty photosensor
X
Fully endusted, clogged or defected photosensor

MOUNTING
5
MOUNTING
MONITOR
Place the monitor on a clearly visible place in the tractor cabine and fix it with
the U-bracket and bolts, up or bottom position to avoid direct sunlight on LCD.
The display is illuminated which enables nighttime use with superb visibility
• The monitor is connected optimally after a fuse (max. 3A) on 12 VDC,
taking care of the right polarity.
• Connect the extension cable of modules to the monitor.
• Do not connect in line with other disturbing signal emitter
devices.
• Welding works are allowed only when both power cables of
the monitor are disconnected from the tractor’s electronic
system.
SPEED SENSOR FOR HECTARE COUNT
Mount speed sensor in front of a non-slipping wheel.
The best is a freewheel which sized to give at lest 1
signal in a distance traveled between 0,2 – 0,99 m.
The speed sensor gives you information about the
distance traveled.
Speed sensors are inductive sensors, in proximity of an iron part e.g. bolt heads
give a signal. If distance between sensing bolt heads would be more than 1
meter, additional bolt signallers has to be mounted. This way, during calibration
the distance traveled in 100 bolt signals remains under 100 meters.
Checking operation:
• red LED at the end of speed sensor
• a symbol of speed sensor is blinking on monitor front
Important: when planning the placement of speed sensor regard the risk
of straw residues or pebbles, they may hurt the sensor.
4-6 mm
Útjeladó
Csavarfej
Very important to adjust speed
sensor within the sensing distance,
generally between 4-6 mm from bolt
head.

MONITOR FRONT
6
MONITOR FRONT
Spin up in settings options.
One touch: spin up
Pushed continuously: spin up in quick time
SWITCH ON
Following switch on appear the system test, which is followed by the display
of test results.
system test
settings
horn
wheel-LED
functions, modes
On, 12V out - light
Shorted cable - dark
Off - dark
backlighted LCD
display
Switch indicator
(red LED)

SYSTEM TEST
7
SYSTEM TEST
The system test is executed:
• every switch on,
• by pressed button on screen of seed control mode
• automatically by change settings of seed sensors.
During test process the monitor detects:
• which modules are connected to the system (seed sensors, speed
module),
• what is the readiness for operation of connected seed sensors
(operability, dust level check),
• Sends data to adjustable modules (DS2000).
Having the test finished, the ‘found’ modules are presented on display:
TEST ........
No photosensors!
Cx COCC
COperating sensor
Odusty sensor
x seeding blockage
unsuccessful test result
TEST function may be used when there is
no seeding in progress!

MENU
8
MENU
Control of Seedong
Blockage
Setting Missing Seed Time
Reset Hectare
Settings
Entry pf Distance Traveled in
100 Speed Signals
Entry of Working Width
100 Speed Signal Count
Setting Seed Size
Language Selection

SEEDING CONTROL
9
SEEDING CONTROL
The monitor simultaneously detects seeding continuity in all rows. Where seed
drop is missing for longer time than preset limit value, seed symbol of that row
(*) will disappear from display and alarm sounds in according length.
During the turnings at landmarks alarm is disabled automatically.
Example of display at a 6-row planter:
Missing seed time: 1.5 sec.
nnnnnnn 015.26
seed sensors
hectare
Rows 1,3,5 and 6 are continuously
seeding within preset limit value.
In rows 2 and 4 seeds are missing within
the 1.5 seconds preset limit value.
nCnCnn 018.48

SETTING BASIC DATA
10
SETTING BASIC DATA
MISSING TIME INTERVAL ADJUSTMENT
See also table on page 16.
CANCEL HECTARE DATA
OTHER SETTINGS
SELECTION OF SEED SIZE
Q*: 1.50 sec
You can set missing seed time interval between
0.25 – 2.00 seconds in 6 steps.
QReset area
push button for at least 2 seconds
2 sec.
QSettings
return to the seeding control mode
to next options
Q*: 6Ý9mm
change size
In order to reach more precise seed detection
when using DS 2000 seed sensors, main seed
characteristics like size shape must be entered.
It brings more efficiency in recognition of
double or triple seed drops.
Inhaltsverzeichnis
Andere Digitroll Steuerungssystem Handbücher