DirectOut Technologies ANDIAMO.MC Montageanleitung

ANDIAMO.MC
Hardware Guide
Version 2.0

page 2 of 72
ANDIAMO.MC Hardware Guide - Version 2.0
Copyright
All rights reserved. Permission to reprint or electronically reproduce any document or
graphic in whole or in part for any reason is expressly prohibited, unless prior written
consent is obtained from the DirectOut GmbH.
All trademarks and registered trademarks belong to their respective owners. It cannot
be guaranteed that all product names, products, trademarks, requisitions, regulations,
guidelines, specifications and norms are free from trade mark rights of third parties.
All entries in this document have been thoroughly checked; however no guarantee for
correctness can be given.
DirectOut GmbH cannot be held responsible for any misleading or incorrect
information provided throughout this manual.
DirectOut GmbH reserves the right to change specifications at any time without notice.
DirectOut Technologies® is a registered trademark of the DirectOut GmbH.
© DirectOut GmbH, 2017

page 3 of 72
ANDIAMO.MC Hardware Guide - Version 2.0
Table of contents
About This Document 5
How to Use This Document.......................................................................... 5
Conventions .................................................................................................. 5
CHAPTER 1: Overview 6
Introduction ................................................................................................... 6
Feature Summary.......................................................................................... 7
Applications................................................................................................... 7
CHAPTER 2: Legal issues & facts 8
Before Installing This Device......................................................................... 8
Defective Parts/Modules ............................................................................. 8
First Aid (in case of electric shock)................................................................ 9
Updates ....................................................................................................... 10
Conditions of Warranty ............................................................................... 10
Intended Operation .................................................................................... 10
Conformity & Certificates ........................................................................... 11
Contact........................................................................................................ 11
Contents...................................................................................................... 12
Accessories................................................................................................. 13
CHAPTER 3: Installation 15
Installing the Device .................................................................................... 15
CHAPTER 4: Operation 20
Introduction ................................................................................................. 20
Global Control.............................................................................................. 21
Menu Control .............................................................................................. 22
Clocking....................................................................................................... 24
Sample Rates .............................................................................................. 26
Output Format............................................................................................. 27
Level Settings.............................................................................................. 28
Level Meters - analog input......................................................................... 29
Display - input channel settings................................................................... 30
Level Meters - analog output ...................................................................... 31
Remote protocol.......................................................................................... 32
Signal Routing ............................................................................................. 34
Connecting MADI ....................................................................................... 37
Connecting Word clock ............................................................................... 38
Connecting GPO ......................................................................................... 38
Connecting USB.......................................................................................... 39
Connecting Analog ...................................................................................... 40

page 4 of 72
ANDIAMO.MC Hardware Guide - Version 2.0
CHAPTER 5: Menu Navigation 42
System Settings .......................................................................................... 42
Input sensitivity (Gain setting)..................................................................... 44
CHAPTER 6: Troubleshooting and Maintenance 47
Troubleshooting........................................................................................... 47
Maintenance................................................................................................ 47
CHAPTER 7: Technical Data 48
Appendix A - DSUB-25 Pin assignment 50
Appendix B - DSUB-9 Pin assignment 51
Appendix C - Sensitivity <> Gain 52
Appendix D - Remote Protocols 55
Overview..................................................................................................... 55
Remote Protocol B - PRE™ (AVID) ............................................................. 56
Remote Protocol C - Yamaha AD8HR ......................................................... 61
Remote Protocol D - SSL ............................................................................ 65
Remote Protocol AB - Lawo Dallis .............................................................. 66
Index 68

page 5 of 72
ANDIAMO.MC Hardware Guide - Version 2.0
About This Manual
About This Manual
How to Use This Manual
This manual guides you through the installation and operation of the device.
Use the Table of Contents at the beginning of the manual or Index Directory at the
end of the document to locate help on a particular topic. You can access more
information and latest news by visiting on the DirectOut website at
www.directout.eu.
Conventions
The following symbols are used to draw your attention to:
TIPS!
indicate useful hints and shortcuts.
NOTES!
are used for important points of clarification or cross references.
WARNINGS!
alert you when an action should always be observed.
This document relates to:
• ANDIAMO.MC - firmware version 4.6

page 6 of 72 ANDIAMO.MC Hardware Guide - Version 2.0
CHAPTER 1: Overview
CHAPTER 1: Overview
Introduction
The ANDIAMO.MC is a high-end 32-channel mic preamp and AD/DA MADI
converter. It provides two MADI inputs and outputs and 32 channels analog
microphone inputs and 32 channels line outputs.
With two RU height, two redundant power supplies and excellent sounding
converters the device offers best and safe audio quality at a minimal need of
rackspace.

page 7 of 72
ANDIAMO.MC Hardware Guide - Version 2.0
CHAPTER 1: Overview
Feature Summary
MADI Ports 2 x SC-Socket multi/single-mode (SC/SC)
or
1 x SC-Socket multi/single-mode &
1 x coaxial BNC connector, 75 Ω (BNC/SC)
MADI Formats 56/64 channel, 48k/96k Frame, S/MUX 2/4
Mic / Line Inputs 32 channels, balanced via DSUB-25,
AES59 compliant
phantom power switchable (+ 48 V)
PAD switchable (30 dB)
Line Outputs 32 channels, balanced via DSUB-25,
AES59 compliant
Sample Rates 44.1, 48, 88.2, 96, 176.4, 192 kHz ±12.5%
Clock Inputs 1 x Word clock, coaxial BNC,
75 Ω termination switchable,
This input also accepts an AES3 frame (AES11).
Clock Outputs 1 x Word clock, coaxial BNC
GPO 2 x MOSFET switch
USB Port USB 2.0 port for firmware updates and remote
control
Routing Matrix Signal routing on a per channel basis
160x160 routing matrix.
Remote Control Software Remote control via USB, Serial over MADI,
MIDI over MADI or DO.Net
support of particular 3rd party protocols:
Yamaha, SSL, Avid PRE, Eucon, Lawo Dallis
Power Supply This device is equipped with two wide range power
supplies (84 V to 264 V AC / 47 Hz to 63 Hz / safety
class 1)
Applications
ANDIAMO.MC can be used for conversion, amplification, monitoring and recording
of analog and digital signals.
Typical applications include:
• recording mic / line signals (32 inputs)
• redundant recording using both MADI I/Os
• 1:2 splitting of analog input signals (input to MADI & D/A line out)
• monitoring a MADI signal (32 line outputs)
• signal distribution (routing matrix)
• format conversion of MADI signals
• ...

page 8 of 72
ANDIAMO.MC Hardware Guide - Version 2.0
CHAPTER 2: Legal issues & facts
CHAPTER 2: Legal issues & facts
Before Installing This Device
WARNING!
Please read and observe all of the following notes before installing
this product:
• Check the hardware device for transport damage.
• Any devices showing signs of mechanical damage or damage from the
spillage of liquids must not be connected to the mains supply, or
disconnected from the mains immediately by pulling out the power lead.
• All devices must be grounded. The device is grounded through its
IEC power connections.
• All devices must be connected to the mains using the three-cord power
leads supplied with the system. Only supply electrical interfaces with the
voltages and signals described in these instructions.
• Do not use the device at extreme temperatures. Proper operation can
only be guaranteed between temperatures of 5ºC and 45ºC and a
maximum relative humidity of 80%, non-condensing.
• The cabinet of the device will heat up. Do not place the device close
to heating sources (e.g. heaters). Observe the environmental conditions.
Defective Parts/Modules
WARNING!
This device contains no user-serviceable parts. Therefore do not open the device.
In the event of a hardware defect, please send the device to your DirectOut
representative together with a detailed description of the fault.
We would like to remind you to please check carefully whether the failure is
caused by erroneous configuration, operation or connection before sending parts
for repair.

page 9 of 72
ANDIAMO.MC Hardware Guide - Version 2.0
CHAPTER 2: Legal issues & facts
First Aid (in case of electric shock)
WARNING!
• Do not touch the person or his/her clothing before power is turned off,
otherwise you risk sustaining an electric shock yourself.
• Separate the person as quickly as possible from the electric power source
as follows:
- Switch off the equipment.
- Unplug or disconnect the mains cable.
• Move the person away from the power source by using dry insulating
material (such as wood or plastic).
• If the person is unconscious:
- Check their pulse and reanimate if their respiration is poor.
- Lay the body down and turn it to one side. Call for a doctor immediately.
• Having sustained an electric shock, always consult a doctor.

page 10 of 72
ANDIAMO.MC Hardware Guide - Version 2.0
CHAPTER 2: Legal issues & facts
Updates
DirectOut products are continually in development, and therefore the information
in this manual may be superseded by new releases. To access the latest
documentation, please visit the DirectOut website:
www.directout.eu.
WARNING!
No compensation can be claimed for damages caused by operation of this unit
other than for the intended use described above. Consecutive damages are also
excluded explicitly. The general terms and conditions of business of DirectOut
GmbH are applied.
Conditions of Warranty
This unit has been designed and examined carefully by the manufacturer and
complies with actual norms and directives.
Warranty is granted by DirectOut GmbH over the period of two years for all
components that are essential for proper and intended operation of the device. The
date of purchase is applied for this period.
Consumable parts (e.g. battery) are excluded from warranty claims.
WARNING!
All claims of warranty will expire once the device has been opened or modified, or
if instructions and warnings were ignored.
For warranty claims please contact the dealer where your device was acquired.
This guide refers to firmware version 4.6
Intended Operation
The ANDIAMO.MC is designed for conversion of audio signals from analog to
digital and vice versa. In this context digital audio refers to a MADI signal (AES10).
Andere Handbücher für ANDIAMO.MC
1
Inhaltsverzeichnis
Andere DirectOut Technologies Verstärker Handbücher