December 14, 2007 D-OC-UM07C.14100 Firmware Version 1.0D
“Your Partners in Network Alarm Management ”
Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs.

© 2007 DPS Telecom
This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this
document may be photocopied without prior written consent of DPS Telecom.
All software and manuals are copyrighted by DPS Telecom. Said software and manuals may not be reproduced, copied,
transmitted or used to make a derivative work, by either mechanical, electronic or any other means in whole or in part,
without prior written consent from DPS Telecom, except as required by United States copyright laws.
The material in this manual is for information purposes and is subject to change without notice. DPS Telecom shall not be
liable for errors contained herein or consequential damages in connection with the furnishing, performance, or use of this
manual.
Notice
5/5/04
Revision History
FSK Converter User Manual released. Supports firmware version 1.0B.
12/14/07 Renamed from FSK Converter to L-Series Protocol Converter.

Contents
Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs
Introduction1.....................................................................1
Shipping List2.....................................................................2
Specifications3 .....................................................................3
Installation4.....................................................................4
Tools Needed4.1 .....................................................................4
Mounting4.2 .....................................................................4
Power Connection4.3 .....................................................................5
Network Connections4.4 .....................................................................6
Craft Port5 .....................................................................7
Tuning the FSK Modem6.....................................................................8
Jumper Options7.....................................................................9
Front Panel Operation8.....................................................................10
Updating Firmware9.....................................................................10
Preparing the L-Series Protocol Converter for Firmware Update9.1 .....................................................................11
Updating Firmware with ComloaderW9.2 .....................................................................11
Updating Firmware with DPSLoad9.3 .....................................................................11
Rebooting the L-Series Protocol Converter9.4 .....................................................................12
Technical Support10 .....................................................................13

1
Introduction1
Fig. 1 - The L-Series Protocol Converter
The DPS Telecom L-Series Protocol Converter interfaces an RS-232 data port to a 20-bit protocol network. The
20-bit hardware interface is either 1200 baud RS-232, or Frequency Shift Keyed (FSK) at 1200 baud with a
center frequency of either 1877 Hz or 9838 Hz.
Note: Hardware interfaces may be sold separately.
The L-Series Protocol Converter with Firmware Version 1.0D is designed to support only one application:
mediating alarm data between the T/Mon or IAM and the Larse Series 1200 remote telemetry units. Each
L-Series Protocol Converter mediates a polling leg of up to 253 Larse Series 1200 remotes.
Note: This device provides a hardware interface to your Larse/Badger RTU network. To poll the network with
an T/Mon or IAM, the Larse Interrogator software module must be installed on your T/MonXM system.
Fig. 1.2 - The L-Series Protocol Converter mediates alarm data between the T/Mon or IAM and Larse/Badger
Series 1200 remotes
Note: Larse and Badger Series 1200 remotes are assets purchased by Badger Alarm and Control, LLC.

2
Shipping List2
While unpacking the L-Series Protocol Converter, please make sure that all of the following items are included.
If some parts are missing, or if you ever need to order new parts, please refer to the part numbers listed and call
DPS Telecom at (800) 693-0351.
L-Series Protocol Converter
D-PK-LS20B-12002- RS-232 User Manual
D-PK-LS20B-12003- FSK 0-4 kHz D-OC-UM07C.14100
D-PK-LS20B-12005- FSK 8-12 kHz
DB9M-DB9F Download Cable 6 ft. Two ½ Amp GMT Fuses
D-PR-045-10A-04
23" Rack Ears 19" Rack Ears
Eight 3/8" Ear Screws and Eight Lock Washers Four Rack Screws
Pads

3
Specifications3
Dimensions: 1¾"H x 17"W x 6"D (4.45 cm x 43.18 cm x 15.24cm)
Mounting: 19" or 23" rack
Power Input: –48VDC (–40 to –70 VDC)
Current Draw: 65 mA
Fuse: ½ amp GMT
Interfaces: 1 female DB25 RS-232 port
1 male DB25/RTU port (FSK or RS-232)
1 female DB9/RS-232 craft port
FSK Frequency Range: D-PK-LS20B-12003 (0-4kHz) D-PK-LS20B-12005 (8-12kHz)
Center = 1877 Hz Center = 9838 Hz
Mark = 2096 Hz Mark = 10416 Hz
Space = 1658 Hz Space = 9259 Hz
Visual Interface: 6 bi-color LEDs
Operating Temperature: 32°–140° F (0°–60° C)
Operating Humidity: 0%–95% noncondensing

4
Installation4
Tools Needed4.1
To install the L-Series Protocol Converter, you'll need the following tools:
Phillips No. 2 Screwdriver Small Standard Screwdriver
Computer
Note: You may also need cable-building equipment to make a connector for connecting your Larse/Badger
Series 1200 remote to the L-Series Protocol Converter.
Mounting4.2
Fig. 4.1 - The L-Series Protocol Converter can be flush or rear-mounted
The L-Series Protocol Converter can be mounted in a 19" rack or a 23" rack by using different rack ears for each
size. Two rack ear locations are provided. Attach the appropriate rack ears in the flush-mount or rear-mount
locations shown in Figure 4.1.

5
Power Connection4.3
POWER BARRIER STRIP
GND
-BATT
FRM
GND
20-24 AWG, 18 AWG maximum
RED WIRE
TO –48 VDC
ALWAYS A
NEGATIVE
POWER
SUPPLY
BLACK
WIRE TO
GND GROUNDS
DEVICE TO
MAKE NEUTRAL
Fig. 4.2 - L-Series Protocol Converter Power Connection
To connect the L-Series Protocol Converter to a power source, follow these steps:
NOTE: Do not apply –48V Power to the L-Series Protocol Converter until all power connections in Step
1 through Step 6 have been completed.
NOTE: Use proper lug terminations on all power and frame ground connections to the L-Series Protocol
Converter power input terminal strips.
1. Remove the fuse from the front panel and turn off the power supply when connecting the power from the
power lead.
2. Connect a –48 VDC line to the –BATT terminal and the ground to the GND terminal.
3. For earth/frame grounding, connect a copper wire to the FRM GND terminal. (DPS Telecom recommends at
least a 14 gauge wire.) Connect the other end of the wire to an earth/frame ground.
4. Turn on main power with the L-Series Protocol Converter fuse still removed.
5. Connect the black common lead of a volt meter to ground and the red lead to –BATT. The meter should read
the battery level (–43 to –53 VDC). If not, check your power supply.
6. Do not reinsert the L-Series Protocol Converter's fuse (powering up the unit) until all other connections have
been made.

6
Network Connections4.4
Fig. 4.3 - L-Series Protocol Converter rear panel connections
The L-Series Protocol Converter's two DB25 network connectors are located on the back panel, as shown in
Figure 4.3.
Connect the LarScan Series 1200 RTU to the male DB25 connector labeled "RTU." Pinouts for the L-Series
Protocol Converter are shown in Figure 4.4.
13121110987654321
252423222120191817161514
TX+ TX–
RX–RX+
Fig. 4.4 - FSK connector pinout
Fig. 4.5 - RS-232 connector pinout

7
Connect the T/Mon or IAM to the female DB25 connector labeled "NOC." Pinouts for the RS-232 connector are
shown in Figure 4.6.
Fig. 4.6- RS-232 connector pinout
Craft Port5
Fig. 5.1 - L-Series Protocol Converter Craft Port.
The L-Series Protocol Converter's DB9 craft port is located on the front panel. The craft port is used to connect a
PC to the L-Series Protocol Converter for modem tuning and firmware downloads. To connect to the craft port,
use the included DB9M-to-DB9F download cable.
Note: The craft port and the RS-232 port use the same circuit. Connecting to the craft port disables all RS-232
polling on the leg connected to the L-Series Protocol Converter. Before connecting a PC to the craft port,
disconnect the RS-232 connection on the back panel.
Pinouts for the craft port are shown in Figure 5.2.
12345
TX
RX
GND
6789
RTS CTS
DSR
Fig. 5.2 - L-Series Protocol Converter craft port pinout.