Drive Pure Expressions RTLBP2000 Bedienungsanleitung

Item # RTLBP2000/2200
INSTRUCTION
MANUAL
ELECTRIC BREAST PUMP
P
ure ™
DUAL CHANNEL
expressions
ADJUSTABLE SUCTION LEVELS
and suction cycles


1
Congratulations on your new
bundle of joy!
Thank you for choosing Pure Expressions Double Electric Breast
Pump RTLBP2000/RTLBP2200. It has been known that the breast
milk is the best natural food for your baby. With our collaboration
with the breastfeeding experts and research with the lovely
breastfeeding mothers who are determined to give the best to
their babies, just like you, our products fulfills the breastfeeding
mother’s needs when circumstances do not make breastfeeding
possible.
Indications For Use
The electric breast pump RTLBP2000/RTLBP2200 is to
express and collect milk from the mother’s breast, to alleviate
engorgement of the breast, maintain the ability of lactation, and
provide mother’s milk for future feedings when separation of
mother and baby occurs.
The device is intended for a single user only, not for hospital use.
All parts that have direct contact with the milk and breast are
BPA free.
Features of Electric Breast Pump
RTLBP2000/RTLBP2200
• Easy to use and ease of assembly, simple button operation and
clear LCD screen
• A real double pump with 2 independent motors.
• Left, right or double expression with individual control.
Dierent suction strength can be set on the left and right breast
independent of each other for your maximum comfort.
• 2 Phase Expression-Stimulation Phase & Expression Phase;
the pumping rhythm mimics a baby’s sucking, for maximum

2
comfort and stimulation.
• 9 Steps Suction Control
• Last used setting memory
* External battery pack; requires 4 new alkaline batteries; not included
• Compact and light weight for maximum portability.
• Silent operation.
• Closed System with Anti-backflow
• All parts that have direct contact with the milk and breast are
BPA free.
Warnings and Precautions
Basic safety precautions should be taken when using electrical
products, especially around children.
WARNING: If you are a mother who is infected with Hepatitis B,
Hepatitis C or Human Immunodeficiency Virus (HIV), pumping
breast milk will not reduce or remove the risk of transmitting the
virus to your baby through your breast milk.
Read all instructions before using. When using any electrical
appliance, basic safety precautions should always be followed,
including the following:
WARNING:
• The power adaptor is a part of the breast pump.
• Always unplug electrical device immediately after use.
• Do not use while bathing.
• Do not place or store device where it can be submerged in water.
• Do not reach for device if it has fallen into water. Immediately
unplug from the electrical outlet.
• Do not leave device unattended when plugged into electrical outlet.
• Do not position the breast pump such that it is dicult to
disconnect the adapter plug from the main power supply.
• Close supervision is necessary when used near children or

3
people with disabilities.
• Use product only for its intended use. Do not use attachments
not recommended by the manufacturer.
• Keep cord away from heated surface.
• Never use while sleepy or drowsy.
• Never drop or insert objects into any opening or tubing.
• Do not use outdoors or operate where aerosol products are
being used, or where oxygen is being administered.
• Always inspect power adapter and batteries prior to use for
damage and exposed wires. If damage is found, immediately
discontinue use of power adapter.
• Do not operate during transportation.
WARNING: To avoid health risk and reduce the risk of injury:
• This device is intended for single user only and should not be
shared between users.
• Do not drive while pumping.
• Never use while pregnant, as pumping can induce labor.
• Clean and sanitize all parts that come in contact with your breast
and breast milk prior to first use. Wash all parts that come in
contact with your breast and breast milk after every use.
• Inspect all appropriate pump components before each use.
• Do NOT continue pumping for more than 2 consecutive
pumping sessions if no results are achieved.
• Do not thaw frozen breast milk in a microwave or in a pan of
boiling water.
• If tubing becomes moldy, discontinue use and replace tubing.
• If breast milk backup occurs, clean the tubing before your next
pumping session.
WARNING: Avoid the following, which could lead to minor injury:
• DO NOT wrap cord around the adapter body.

4
• Use only the power adapter that comes with the Double
Electric Pure Expressions breast pump.
• Pump only with the breast pump in the upright position.
• DO NOT shorten the tubing.
• Make sure the voltage of the power adapter is compatible with
the power source.
• Plug the adapter into the breast pump first, then into the power
source.
• DO NOT use antibacterial or abrasive cleaners/detergents when
cleaning breast pump or breast pump parts.
• Never put the breast pump motor in water or sterilizer, as
permanent damage can result to the device.
• DO NOT attempt to remove the breast shield from your breast
while pumping. Turn the breast pump o and break the seal
between your breast and the breast shield with your finger,
then remove the breast shield from your breast.
• If pumping is uncomfortable or causing pain, turn the unit o,
break the seal between the breast and breast shield with your
finger and remove the breast shield from your breast.
NOTES:
Plastic bottles and component parts become brittle when frozen
and may break when dropped.
Take appropriate care in handling bottles and components.
Do not use the breast milk if bottles or components become
damaged.
When the breast pump is working, it won’t cause any electrical
problems on household appliances. But, high power household
appliances (such as food processing machines) and kitchen
appliances (such as microwave ovens) may aect the breast
pump’s normal working.
SAVE THIS INSTRUCTION MANUAL

5
Parts Guide
01 Dust Cover x 2
02 Silicone Cushion x 2
03 Breast Shield body x 2
04 Cap Plug x 2
05 Cap x 2
06 Seal Ring x 2
07 Damper x 2
08 Grid x 2
09 Tubing Connector x 4
10 Adapter x1
11 Tubing x 2
12 Pump unit x1
13 Membrane x 2
14 Valve Body x 2
15 Bottle Stand x 2
16 Wide Neck Bottle 4oz x 2
17 Bottle Adapter x 2
18 Nipple x 2
19 Disc Collar x 2
20 Nipple Dust cover x 2
21 Bottle Lid x 2
Additional parts:
Membrane x 4 Pump carry tote bag x 1
External battery pack x 1 Insulated cooler bag
(available with RTLBP2200)
(requires 4 new AA alkaline batteries, not included)

6
BP001 Breast Pump Carry Bag
BP002 Insulated Cooler Bag
BP004 6oz wide neck storage bole with cap
BP005 27MM Pump Kit w/out Insert
BP006 24MM Silicone Insert
BP007 Valve Set - pair w/membrane
BP008 Membrane (4pcs per bag)
BP009 Tubing set (2pcs)
BP0011 6V Power Adaptor for RTLBP2000/RTLBP2200
BP0012 6V External baery pack for RTLBP2000/RTLBP2200
BP0013 31MM Pump Kit w/out Insert
BP0014 27MM Silicone Insert
BP0015 Feeding Nipple Set
BP0016 Base (base to hold boles)
Additional Accessories sold separately:

7
How to assemble the Expression
collection Kit
The electric breast pump comes pre-assembled, however you
need to re-assemble it after each cleaning. Before assembling, the
parts that come in contact with breast milk directly, including milk
bottle, silicone cushion, breast shield body, membrane, valve, grid,
damper, bottle cap, disc collar (if use standard bottle), should be
cleaned and sterilized each time.
1. Assembling the Expression collection combo kit
Slot in the (02) Silicone Cushion into (03) breast shield body
and then slot in the (01) Dust Cover to form the complete (a)
Expression collection combo kit.

8
2. Assembling the Cap Combo
Make sure the Cap Plug 04 is plugged into the hole of the Cap 05
and ensure it is tightened securely.
Place the Damper 07 onto the Grid 08 and then place the Cap 05
onto it to form a complete (b) Cap Combo.
Put the Seal Ring 06 on the head of (a), then screw (b) onto the
breast shield body 03, and make sure it is tightened and secure to
avoid air leakage.
3. Assembling the Valve
Place the Membrane onto the Valve
Body by pressing the Membrane into
the installation holes as illustrated.
Make sure the Membrane is completely
flat and tight with no visible gap. Mount
the Valve Body to the Breast Shield
Body securely as illustrated.
a
03 06