METRO 70 - INSTRUCTION FOR INSTALLATION
English
1. Introduction
The appliance is available in two models, the Metro 70 and the Metro 70 Tunnel. This version of the Metro 70 and
the Metro 70 Tunnel is suitable for natural gas. It is not possible to make the appliance suitable for a different type of
gas by using a so-called conversion set. The Metro 70 is a ‘standard’ gas fire and should always be installed against
a wall. The Metro 70 Tunnel is just that, a ‘tunnel fire’ with both a front and back window.
The Metro 70 and the Metro 70 Tunnel are closed decorative fires. A closed tunnel draws its combustion air from
outside and not from the living area. This is done by way of a combined system that discharges the flue gases and sup-
plies the combustion air. In this concentric system the outer pipe serves as air supply and the inner pipe as the flue.
This system can be installed through either the outer wall or the roof.
The appliances are built into a chimney breast. The DRU product range includes several chimney breasts.
The chimney breast must be well ventilated to ensure a good heat distribution. DRU can supply various ventilation
elements. The appliances are supplied with a wireless, battery-operated remote control.
2. EC Declaration of Conformity
We hereby declare that the design and construction of the decorative gas heating appliance marketed by DRU con-
forms with the essential requirements of the Gas Appliance Directive.
This declaration will be rendered invalid should the appliance be altered in any way without the written consent of
DRU.
Product: Decorative gas heating appliance
Type: Metro 70
Metro 70 Tunnel
Applicable EC Directives: 90/396/EEC
Applicable harmonised standards: NEN-EN-613
NEN-EN-613/A1
In-house measures guarantee that serially produced appliances always conform with the essential requirements of
the current EC Directives and the applicable standards.
R. Gelten
DRU VERWARMING B.V.
Postbus 1021, 6920 BA Duiven
Ratio 8, 6921 RW Duiven
www.dru.nl
3. SAFETY
3.1 General
N.B. - Please read this chapter on safety carefully before commencing installation or maintenance
- Always observe universal regulations and the precautionary measures / safety instructions in this manual.
3.2 Regulations
The appliance should be installed in compliance with current national, local and constructional (installation) regulations.
3.3 Precautionary measures / safety instructions regarding installation
Observe the following precautions / safety regulations precisely:
➠
You may only install and/or service this appliance if your are a qualied installer skilled in installing decorative gas res;
➠
do not adjust the appliance in any way;
➠
Use inammable and heat-resistant materials for building a chimney breast, including the back wall, the inside and the
top of the chimney breast;
➠
the minimum internal dimensions required for the chimney breast must be taken into account;
➠
the chimney breast should be ventilated by vents with total free vent area of 200 cm2;
➠
only use the ue /combustion air supply systems supplied by DRU;
➠
use the wall brackets supplied to mount the appliance;
➠
do not install the appliance at against the back wall;
➠
leave the space between the feet free;
➠
do not cover and/or pack the appliance with an insulating blanket or any other material;
➠
make sure combustible objects and / or materials have a minimum distance from the appliance of 500 mm;
➠
only use the log/pebble set supplied;
➠
arrange the logs/pebbles exactly as described;
➠
leave a space around the pilot burner;
UK