Ⅰ: DB01 parameters
•Model: DB01
•Communication method: BLE 5.0
•Recording capacity: 4MB. About 100,000 groups of data can be
recorded.
•Broadcasting interval: 1000ms (can be modified, recommended
not to exceed 5000ms)
•Storage interval: 5 minutes (can be modified, 30s~1 hour)
•Broadcast power: +8dbm (can be modified, -8~+8dbm, the greater
the power leads to the greater the power consumption).
•Broadcasting range: The maximum open area can reach 500
meters.
•Temperature range: -20℃~60℃
•Humidity measurement range: 0%RH~100%RH
•Storage conditions: +5 C ~ +35 C, 45%RH~85%RH
•Measurement accuracy: 0.2℃(0℃~60℃), 0.5℃(other)
2%RH(20RH~80%RH), 3%RH(other)
•Light perception: photoresistor. 0mv~3V
•Gravity sensor: support vibration alarm, tilt alarm.
ShenZhen Eelink Communication Technology Co., Ltd. 2
•Data communication: Connect to a computer via APP or
USB to obtain historical data of the recorder. APP
synchronization can be uploaded to the cloud.
•Data format: PDF/CSV file
•Working mode: cycle overwrite storage
•Alarm condition: single type
•Alarm mode: display the alarm symbol on the LCD screen
and the indicator light flashes
•Protocol: custom broadcast protocol, Eddystone,iBeacon;
•Support windows 7/8/10 operation system
•Battery: Button battery. Use 1-2 years.
•Waterproof level: IP65
Note:
•The battery life of the device is closely related to the
device power, collection interval, storage interval, screen
status, alarm status, data transmission times, and
ambient temperature and humidity.
•Used for about 30 days under the condition that the
screen is always on, the alarm indicator keeps flashing,
store data every 5 minutes.
•Used about 2 years under the condition that the screen is
off, collect/store data every 5 minutes.

Ⅱ: Menu Functions
The menu interface has 4 pages: main menu, maximum/minimum menu, alarm upper and lower limit menu, historical data curve;
•Main menu: The main menu displays the current working status of the device which includes alarm information, current temperature,
current humidity, average temperature, average humidity, number of records, and battery power.
ShenZhen Eelink Communication Technology Co., Ltd. 3
Not Started Status Started Status Alarm Status
①The current temperature and
humidity in the environment.
②The average temperature and
humidity from the beginning to
the present.
③The recording status.
④The number of records that the
device has stored.
⑤Battery power level.
⑥Bluetooth status: broadcast
status/connection status.
⑦Device time.
Alarm icon from top to bottom:
1. Light alarm icon
2. Temperature alarm icon
3. Humidity alarm icon
4. Vibration alarm/tilt alarm icon

•Maximum/Minimum Menu:Maximum and minimum temperature/humidity.
ShenZhen Eelink Communication Technology Co., Ltd. 4
Started Status
Not Started Status
MAX:
The maximum value of temperature and humidity
from the start record to the current time
MIN:
The minimum value of temperature and humidity
from the start record to the current time
No Maximum and minimum value when device is
not started.
•Upper and lower limit menu:Set the upper and lower limits of the temperature and humidity alarm of the device
through APP. When it exceeds the set range, the indicator will flash quickly.
↑The up arrow indicates the upper limit. The alarm will be triggered
immediately if the upper limit is exceeded.
↓The down arrow indicates the lower limit.The alarm will be
triggered immediately if the lower limit is exceeded
The alarm recovery period is 3 minutes.

•Historical Data Curve
ShenZhen Eelink Communication Technology Co., Ltd. 5
1)The screen can only display the temperature history curve
of the latest 120pcs data.
2)The upper left corner shows the upper limits of the temperature.
The lower left corner shows the lower limits of the temperature.
3)The upper right corner is the date.The lower right corner is the time.

Ⅲ: Hardware function
ShenZhen Eelink Communication Technology Co., Ltd. 6
Indicator:
The battery level is displayed on the screen:
Screen Status:
1.After being lighted for 5 seconds by default, the screen goes
to sleep again.
•When the Bluetooth status changes, the screen will light up.
•Tap the button and the screen will light up.
When device start, long press the left
button, the indicator light flashes once
to indicate successful mark.
Please replace the battery in time when the
battery voltage is lower than 2800mV.
2.The screen is always on:
•Not recommend to use this mode because it
consumes a lot of power.

Key Function:
ShenZhen Eelink Communication Technology Co., Ltd. 7
Left key + right key: turn on/off Bluetooth broadcast
On: Bluetooth icon in the Screen status bar. Off: No Bluetooth icon in the Screen status bar.
ON OFF
Not started Started
Short Press
Long press 3seconds
Short Press
Long press
3seconds
Left Key
Menu page flip
Start to record
Menu page flip
Mark data
Right Key
Back to main menu
View device QR code
Back to main menu
Stop record

Ⅳ:USB tool introduction
ShenZhen Eelink Communication Technology Co., Ltd. 8
Connect the device with the computer via USB. Use the E2L USB HID reading tool to obtain the cached data in the device. The tool
language changes with the computer system language.
First, Run E2L USB HID setup.exe,Install the reading tool.
After the software is installed, an icon will be generated on the desktop.
Double-click to open the software.

•Export data
Open the E2L USB HID data management system and plug the device directly into the USB port of the computer. Click "Connect
Device". Select the query period or directly click QueryAll to import the historical data
The queried data can be viewed in the form of a table/curve to
view the historical data of temperature and humidity.
Table page: Present temperature and humidity historical data in
the form of a list.
Curve page: Presents historical temperature and humidity data.
Alarm page: Covers the light perception, vibration, and tilt
alarms during the period.
Marker page: the time stamp covering the period.
Click Export, you can save it locally on your computer in
PDF/CSV format.
ShenZhen Eelink Communication Technology Co., Ltd. 9

•Device Parameters
Click the device parameters to know the configuration of the device.
Current time: the device time when the device
parameter is clicked.
Temperature and humidity information: The
device's temperature and humidity alarm
conditions, Exceed the upper limit or lower
limit to trigger the alarm.
In subsequent versions, you can configure the
configurable items of the device on this
interface.
10ShenZhen Eelink Communication Technology Co., Ltd.