EHS XDry Bedienungsanleitung

USER MANUAL
Please read this instruction manual in FULL before
operating and keep in a safe place for future reference
DEHUMIDIFIER

Important Safety Instructions
1. DO NOT use this unit for functions other than those described in
this instruction manual.
2. The dehumidifier works within the room temperature range of
1~40oC.
3. Do not operate the unit with a damaged cord or plug, after it
malfunctions or has been dropped or damaged in any way.
Return to an authorised service facility for examination and repair.
4. This product is intended for domestic and light office use ONLY
and not for commercial, industrial or outdoor use.
5. Close supervision is necessary when any appliance is used by or
near by children and pets.
6. Do not run power cord under carpeting, or cover with rugs or
runners.
7. Never operate or store the unit in direct sunlight.
8. Transport & store the unit in an upright position only.
9. Always place the unit on an even, level surface.
10. Ensure the unit is connected to an earthed power supply of the
correct rating. (Refer to the rating label located at the back of the
unit).
11. DO NOT cover or obstruct the appliance’s inlet and outlet grilles.
12. Never unplug the appliance while it is working, this could damage
the electronic circuits.
13. DO NOT use the appliance in a wet room, such as a bathroom to
avoid the risk of electrical shocks.
14. DO NOT use the appliance with wet or damp hands.
15. DO NOT sit or place articles on the appliance.
16. DO NOT let chemical substances come into contact with the
appliance.
17. DO NOT use the appliance in the presence of flammable
substances or vapours such as alcohol, insecticides, petrol..
18. The use of an extension cable is not recommended.
19. Keep a safe operating distance around the dehumidifier of at least
50cm.
20. Always empty the water tank before storing the unit away.
1

Parts Description
Control panel
Air outlet
Water tank
Hand grip to pull out
the water tank
Handle
Air inlet
Continuous drain
hole
Power cord
Cord tie
Power cord tie hole
Automatic louvre
Water level viewer
Air filter
2

Control Panel
FULL CHECK
hr
TIMER
SWING
UP
FRONT
WIDE
DRY
LAUNDRYON/
OFF
AUTO
LOW
HIGH
SAVING
TURBO
2
4
8
Power Key
Timer key
Louvre Swing Control key
Auto Dry Mode key
Laundry Mode key
Timer indicators
Function indicators
Louvre swing indicators
Water Full indicator
Indicator lights up when the water tank is full or
incorrectly installed.
Check indicator
Indicator lights up when the unit has malfunctioned.
3

Control Panel Operating Instructions
DRY mode
4
FULL CHECK
hr
TIMER
SWING
UP
FRONT
WIDE
DRY
LAUNDRYON/
OFF
AUTO
LOW
HIGH
SAVING
TURBO
2
4
8
Connect the BS three pin plug to the appropriate electrical socket
outlet
Press the ON/OFF button to turn the appliance ON.
Press the ON/OFF button again to turn the appliance OFF
Note: In the event of a power failure
Once the power is restored after a power failure, the appliance will
continue to operate at the selected settings prior to the power failure.
This includes the drying mode, swing function and time remaining in
timer mode.
Note: After turning the appliance OFF
After turning the appliance OFF using the ON/OFF button, the fan
will continue to run for a two minute period. This is a normal
procedure and helps to cool & protect the internal components.
During this two minutes DO NOT remove the BS three pin plug from
the electrical socket outlet; wait for the fan to stop running.

5
Control Panel Operating Instructions
DRY mode
AUTO LOW HIGH
MODE
Press the DRY button through the sequence below:
DESCRIPTION
AUTO
LOW
HIGH
The dehumidifier operates to achieve room conditions between
55 & 60% Relative Humidity
The fan speed & heater power are adjusted automatically
The dehumidifier operates in LOW fan speed & low heater power
The dehumidifier operates to achieve room conditions between
40 & 45% Relative Humidity
Fan speed is always high & the heater power is adjusted
automatically
MODES
Heater
Under 35oC Over 40oC
Over 60oC High Low Low OFF
OFF OFF OFF
Low Low OFF
OFF OFF OFF
High Low OFF
OFF OFF OFF
High
High
Low
Low
Low
Under 55oC
Over 60oC
Under 55oC
Over 50oC
Under 45oC
35~40oC
Room Temperature
Fan Speed
Room
Humidity
(%RH)
AUTO
LOW
DRY
HIGH

6
Control Panel Operating Instructions
LAUNDRY mode
MODE
Press the LAUNDRY button through the sequence below:
DESCRIPTION
SAVING
TURBO
Suitable operation for Summer time power saving
Dehumidifies the air whilst ventilating the room
The fan speed is high & the heater typically operates in low power
Suitable operation for drying clothes in the Winter
The fan speed is always high & the heater typically operates at
high power. The humidity target is approximately 40% RH
MODES
Heater
Under 15oC Over 40oC
Over 40oC High High Low OFF
Low Low OFF
Low OFF OFF
Low OFF OFF
High
High
High
High
Low
High
Low
Under 35oC
Over 60oC
Under 55oC
35~40oC15~35oC
Room Temperature
Fan
Speed
Room
Humidity
(%RH)
TURBO
SAVING
L
A
U
N
D
R
Y
TURBOSAVING

Press the AUTO SWING button through the sequence below :
UP FRONT WIDE
HOLD (LED OFF)
Control Panel Operating Instructions
AUTO SWING LOUVRE
MODE DESCRIPTION
UP
FRONT
WIDE
HOLD
The automatic louvre swings in an upward direction through 90°
The automatic louvre swings in a forward direction through 60°
The automatic louvre swings in a wide angle through 150°
The automatic louvre stops swinging and is held at that position at
the moment the button is pressed
7

8
Control Panel Operating Instructions
TIMER mode
2hrs 4hrs 8hrs
continuous (LED OFF)
Press the TIMER button to set running hours (2, 4 or 8 hours).
When the timer is set the corresponding LED(s) will be illuminated
displaying the time remaining.
When no TIMER is set the LED(s) will be OFF.

Emptying the Water Tank
Lift by the handle
Pull tank out Remove the cover Pour the water contents
Refit the cover Restore the tank
9
1. When the tank is FULL the ‘FULL’ LED on the control panel will
illuminate and the dehumidifier will stop operating after several
minutes.
2. DO NOT move the appliance while the tank is full, as this can lead
to water spillage and create a potential hazard.
3. To remove the tank, grip the tank firmly by the bottom edge and
pull it out. Any spillage should be dried immediately to avoid a
potential hazard.
NOTE:
Clean the tank using warm water with a mild detergent. Do not use
solvents or abrasive materials.
When handling the tank, due care is required to prevent damaging the
float. Do not attempt to remove the float. An incorrectly fitted or
damaged float will prevent the dehumidifier from working.
The ‘FULL’ LED will illuminate if the tank is not fitted correctly or the
float is damaged.
Dieses Handbuch passt für folgende Modelle
1