ELTEX ES60 Series Bedienungsanleitung

Operating Instructions
BASE IONIZER
Series ES60 vario Power Supply
for AC operation
BA-en-2088-2207
F01089y

2BA-en-2088-2207_ES60

BA-en-2088-2207_ES60 3
List of contents
1 Outline of appliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Identification of risks and hazards . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.3 Work and operational safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.4 Technical advance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Installation and assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.1 Assembling the power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 Ground connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.3 Discharging bars, ion blower nozzles, ion blower pistols and
distributors suitable for connection. . . . . . . . . . . . . . . . . . . . . . . . . 10
3.4 Connecting the high voltage cable . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.5 Maximum active bar length and length of the high voltage cable . 11
3.6 Connecting the supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.7 Conneting the function signal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.2 Operating mode with conductive substrates . . . . . . . . . . . . . . . . . . 13
5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.2 Discharging bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6 Trouble-shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7 Technical specifications ES60 . . . . . . . . . . . . . . . . . . . . . . . . . . 16
8 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9 Spare parts and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

4BA-en-2088-2207_ES60
Dear Customer,
The ES60 high voltage power supplies are power supply units for AC
operation discharging bars.
The discharging bars and the ES60 power supply are used mainly in
cases where disruptive static charges impair production processes and
need to be eliminated.
The ES60 power supply features the following characteristics:
• 5 plug-type high voltage outputs
• stable 5 kV AC output voltage
• optional function monitoring
• small dimensions
• easy installation
• protection class IP54 design
Please read the operating instructions carefully before starting the instru-
ment. This will help you prevent personal injuries and damage to property.
Please give us a call if you have any suggestions, proposals or ideas for
improvements. We greatly appreciate the feedback from the users of our
appliances.

BA-en-2088-2207_ES60 5
1. Outline of appliance
1 Power supply lead
2 High voltage terminals (5 pcs)
3 Fuse (type: see name plate)
4 ON/OFF switch (ON = illuminated)
5 Plug for functional signal (only for functional monitoring, optional)
6 Grounding terminal
7 Mounting bracket
Fig. 1:
ES60 high voltage
power supply for
AC operation
Z-118094y

6BA-en-2088-2207_ES60
2. Safety
The ES60 Power Supplies have been designed, built and tested using
state-of-the-art engineering, and have left the factory in a technically and
operationally safe condition. If used improperly, the units may neverthe-
less be hazardous to personnel and may cause injury or damage. Read
the operating instructions carefully and observe the safety instructions.
For warranty conditions, please refer to the General Terms and Conditions
(GTC), see www.eltex.de.
2.1 Proper use
The ES60 Power Supplies may be operated only in connection with the
appropriate Eltex discharging bars for AC operation as well as the ion
blower nozzles, ion blower pistols and distributors, , each with a perma-
nently connected high voltage cable.
Modifications or changes made to the power supplies are not permitted.
Use only original Eltex spare parts and equipment.
The manufacturers will not assume any liability and warranty if the units
are used improperly or used outside the intended purpose.
2.2 Identification of risks and hazards
Possible risks and hazards resulting from the use of the power supplies
are referred to in these operating instructions by the following symbols:
Warning!
This symbol appearing in the operating instructions refers to operations
which, if carried out improperly, may result in serious personal injuries.
Caution!
This symbol appearing in the operating instructions refers to operations
which, if carried out improperly, may result in damage to property.
2.3 Work and operational safety
Warning!
Carefully observe the following notes and the complete chapter 2 "Safety”,
page 6!
Always observe the rules and regulations applying in your country with re-
ference to electrical appliances.
• Before carrying out repairs, cleaning or maintenance work involving the
power supplies and the discharging bars, switch off the power supply
and disconnect the mains power supply (see chapter 5 "Maintenance”,
page 14, chapter 6 "Trouble-shooting”, page 15).

BA-en-2088-2207_ES60 7
• If electrically conductive substrates or substrates coated with conduc-
tive material (e.g. metal foil or metal composites) are used, the mains
supply must be interrupted (see chapter 4.2 "Operating mode with con-
ductive substrats”, page 13).
•Before carrying out any work involving the units, the machine which has
the units fitted must not be in operation (see chapter 5 "Maintenance”,
page 14, chapter 6 "Trouble-shooting”, page 15).
• Any work involving the units must be carried out by qualified electrici-
ans (see chapter 5 "Maintenance”, page 14, chapter 6 "Trouble-shoo-
ting”, page 15).
• Before starting the unit make sure that the appliance is permanently
grounded via the grounding terminal (5, Fig. 1). The ground cable
should have a minimum cross section of 1.5 mm2(see chapter 3.2
"Ground connection”, page 10).
• Check the power supplies and the discharging bars at regular intervals
for any damage to the electrical wiring and the high voltage cables. Any
damaged components must be repaired or replaced before continuing
to operate the units.
• If the housing cover is removed and the supply voltage is switched on
at the same time, contact protection is no longer effective. Always dis-
connect the power before opening the power supply units.
• The protection class IP54 only applies if the housing cover is closed
and the cable connections are shrouded.
• Connect/disconnect the discharging bars only if the power supply unit is
switched off (see chapter 3.4 "Connecting the high voltage cable”,
page 10).
• In applications involving moving bars, the high voltage cable must be
attached such that there is no cable movement near the connection
zone of the power supply unit (see chapter 3.4 "Connecting the high
voltage cable”, page 10).
• Both the lengths of the high voltage cable and of the active bars are
limited, observe maximum lengths (see chapter 3.5 "Maximum active
bar length and length of the high voltage cable”, page 11).
•To ensure that no voltage is supplied to the bars when the material web
is at rest, enabling the supply voltage to the power supply via machine
contact is recommended. If the material web is at rest, or if the machine
is not in operation, no high voltage is supplied to the bars in this case
(see chapter 3.6 "Connecting the supply voltage”, page 12).
•Before starting up the power supply the user must make sure that the
power supply and the bars have been installed and assembled cor-
rectly. The supply voltage can then be switched on (see chapter 4.1
"Startup”, page 13).

8BA-en-2088-2207_ES60
• The power supply must be checked regularly to ensure its proper func-
tioning. The connections of the high voltage cables must be free of dirt
and other foreign matter (see chapter 5.1 "Power supply”, page 14).
• Make sure that the bars are clean at all times. Dirt results in malfunc-
tions and in premature wear of the units.
• When cleaning do not soak the bars and the high voltage cable in sol-
vent and do not damage the emission tips; allow the solvent to evapo-
rate completely before restarting the unit (see chapter 5 "Maintenance”,
page 14, chapter 6 "Trouble-shooting”, page 15).
• Potential risk for wearers of cardiac pacemakers:
Moving the chest closer than 3.5 cm to the emission tips of the
discharging bars or making surface contact with several emission tips
(touching a single tip is not critical) can result in a temporary switchover
of the cardiac pacemaker into the fault mode. Permanent proximity or
contact can therefore cause severe problems.
If it is likely that the chest of such a person comes closer than 3.5 cm to
the emission tips of the discharging bar, or if several emission tips are
touched at the same time, the appropriate warning notices must be
displayed.
• The operation of the bars can generate ozone. The ozone concentra-
tion levels developing near the bars depend on many different factors
such as site of installation, bar current and voltage, air circulation, etc.,
and can therefore not be specified in general terms. If the maximum
allowable concentration of ozone must be observed at the site of instal-
lation of the bar, the concentration must be measured on site.
The AGW value (maximum admissible concentration) serves to assess
the ozone concentration at the workplace. The user must make sure
that the appropriate national AGW value is at no times exceeded, e.g.
in Germany the ozone concentration occurring during the operation of
the system must not exceed the recommended value based on interna-
tional limits of 0.06 ml/m³ (0.12 mg/m³).
2.4 Technical advance
The manufacturer reserves the right to make changes to the technical
specifications without prior notice in order to adapt the units to state-of-
the-art engineering. Eltex will provide the latest information on any
changes or modifications in the operating instructions on request.

BA-en-2088-2207_ES60 9
3. Installation and assembly
3.1 Assembling the power supply
The power supply is designed for wall mounting. Attach using the brackets
provided (installation dimensions, see Fig. 2). The operating elements of
the power supply and the terminals must be freely accessible at all times
and the display LEDs must be visible.
Z-118094y_2
Fig. 2:
Dimensions, ES60 Power Supply

10 BA-en-2088-2207_ES60
3.2 Ground connection
A permanent ground connection must be made via the grounding terminal
(5, Fig. 1). The ground cable should have a minimum cross section of
1.5 mm2.
3.3 Discharging bars, ion blower nozzles, ion blower pistols and
distributors suitable for connection
Eltex discharging bars for AC operation as well as the ion blower nozzles,
ion blower pistols and distributors can be connected to the ES60 power
supplies, each with a permanently connected high voltage cable.
3.4 Connecting the high voltage cable
Warning!
Connect or disconnect the high voltage cables only with the power supply
switched off!
Connect the discharging bars to the power supply using the prefabricated
high voltage cable. Push the high voltage cables into the sockets up to the
stop. Then secure the adapter in the socket with the clip provided (see
Fig. 3).
Cables without flexible tube and cables with plug-type adapters are
plugged in flush and secured with the clip.
Warning!
In applications involving moving bars, the high voltage cable must be
attached such that there is no cable movement near the connection zone
of the power supply unit.
Fig. 3:
Connecting the
high voltage cable
Z00004y
Inhaltsverzeichnis
Beliebte Luftionisator Handbücher anderer Marken

Phonocar
Phonocar 04971 Bedienungsanleitung

Klarstein
Klarstein ST. OBERHOLZ OFFICE Bedienungsanleitung

Life Ionizers
Life Ionizers Fuzion Bedienungsanleitung

ITW
ITW Simco-Ion IQ Power Fantom Bedienungsanleitung

LIFE Ionizer
LIFE Ionizer M7 X NG Bedienungsanleitung

Meech
Meech Hyperion 971IPS Bedienungsanleitung