Equalizer HP350SD Montageanleitung

HP350SD, HP550SD
HP1000SD
DOUBLE ACTING
HYDRAULIC SEALED
HAND PUMPS
Operator Instruction Manual
www.equalizerinternational.com
INNOVATION IN ITS MOST FUNCTIONAL FORM


HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL PAGE 1
SECTION CONTENTS PAGE NO.
1 INTRODUCTION 1
2 SAFETY INFORMATION 2-3
3 KIT COMPONENTS 4
4 TECHNICAL DATA 5
5 HOW THE HAND PUMPS WORK 6
6 INSTALLATION AND OPERATION 7-9
6.1 HP350SD, HP550SD, HP1000SD 7-9
7 EXAMINATION, MAINTENANCE AND STORAGE 10
8 PARTS LISTS 11-13
9 WEIGHTS AND DIMENSIONS 14
10 TROUBLESHOOTING 15-16
The HP350SD, HP550SD and HP1000SD Hydraulic Hand Pumps output is regulated to 700
bar (10,000 psi) and is delivered from an output port threaded ⅜” NPT. The HP350SD,
HP550SD and HP1000SD can be used with any double acting 700 bar (10,000 psi) rated
hydraulic equipment.
The diaphragm oil reservoir means that, unlike conventional hand pump units, the HP350SD,
HP550SD and HP1000SD are operable at all angles and are highly resistant to accidental
spillage of hydraulic uid.
Pressure rating:
●1st stage: 13.8 bar (197 psi)
●2nd stage: 700 bar (10,000 psi)
INDEX
1. INTRODUCTION
HPSD_IM_REV_04
06/06/14

HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL PAGE 2
2. SAFETY INFORMATION
The operator MUST read this manual prior to using the tools.
Failure to comply with the following cautions and warnings could cause equipment
damage and personal injury; read the manual fully!
Read all the following instructions, warnings and cautions carefully. Follow all safety
precautions to avoid personal injury or property damage during system operation.
Equalizer International Ltd cannot be responsible for damage or injury resulting from unsafe
product use, lack of maintenance or incorrect product and/or system operation. Contact
Equalizer International Ltd when in doubt as to the safety precautions and applications. To
protect your warranty, use only good quality hydraulic oil of the grade 15cSt.
Only people competent in the use of hydraulic equipment should use these tools.
In all installations the site safety requirements must be adhered to. ALSO the safety of the
operator, and when present, any assisting personnel, is of paramount importance along with
the safety of others including, when present, the general public.
These instructions are only to cover the safe operation of THE EQUALIZER HP350SD, HP550SD
AND HP1000SD HYDRAULIC SEALED HAND PUMPS during normal maintenance/installation
operations. All other safety aspects must be controlled by the operation supervisor.

HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL PAGE 3
A CAUTION is used to indicate correct operating or maintenance procedures and practices to
prevent damage to, or destruction of equipment or other property.
A WARNING indicates a potential danger that requires correct procedures or practices to avoid
personal injury.
A DANGER is only used when your action or lack of action may cause serious injury or even
death.
IMPORTANT: Operator must be competent in
the use of hydraulic equipment. The operator
must have read and understood all instructions,
safety issues, cautions and warnings before
starting to operate the Equalizer equipment.
WARNING: To avoid personal injury and
possible equipment damage, make sure all
hydraulic components are rated to a safe
working pressure of 700 bar (10,000 psi)
WARNING: Do not overload equipment. Over-
loading causes equipment failure and possible
personal injury.
CAUTION: Make sure that all system compo-
nents are protected from external sources of
damage, such as excessive heat, ame, mov-
ing machine parts, sharp edges and corrosive
chemicals.
CAUTION: Avoid sharp bends and kinks that
will cause severe back-up pressure in hoses.
Bends and kinks lead to premature hose failure.
Do not drop heavy objects onto hoses. A sharp
impact may cause internal damage to hose wire
strands; applying pressure to a damaged hose
may cause it to rupture. Do not place heavy
weights on the hoses, or allow vehicles to roll
over the hoses; crush damage will lead to pre-
mature hose failure.
WARNING: Immediately replace worn
or damaged parts with genuine Equalizer
parts. Equalizer parts are designed to t
properly and withstand rated loads. For
repair or maintenance service contact your
Equalizer distributor or service centre.
DANGER: To avoid personal injury keep
hands and feet away from the tool and
workpiece during operation.
WARNING: Always wear suitable clothing
and Personal Protective Equipment (PPE).
DANGER: Do not handle pressurised hos-
es. Escaping oil under pressure can pen-
etrate the skin, causing serious injury. If
oil is injected under the skin, seek medical
attention immediately.
WARNING: Never pressurize unconnected
couplers. Only use hydraulic equipment in
a connected system.
IMPORTANT: Do not lift hydraulic equip-
ment by the hoses or couplers. Use the car-
rying handle or other means of safe trans-
port.
CAUTION: Do not operate the equipment
without lubricating all moving parts. Use
only high pressure molybdenum disulphide
grease.

HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL PAGE 4
3. KIT COMPONENTS
HP350SD KIT COMPONENTS
1 x HP350SD Pump Unit
1 x Pressure Gauge
1 x ⅜” Port Gauge Adaptor
1 x Instruction Manual
1 x Cardboard Packaging
Product Code: HP350SDMIN
HP550SD KIT COMPONENTS
1 x HP550SD Pump Unit
1 x Pressure Gauge
1 x ⅜” Port Gauge Adaptor
1 x Instruction Manual
1 x Cardboard Packaging
Product Code: HP550SDMIN
HP1000SD KIT COMPONENTS
1 x HP1000SD Pump Unit
1 x Pressure Gauge
1 x ⅜” Port Gauge Adaptor
1 x Instruction Manual
1 x Cardboard Packaging
Product Code: HP1000SDMIN

HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL PAGE 5
4. TECHNICAL DATA
STAGE HP350SD HP550SD HP1000SD
PUMP TYPE TWO SPEED TWO SPEED TWO SPEED
PRESSURE RATING 1st 13.8bar (197psi) 13.8bar (197psi) 13.8bar (197psi)
2nd 700bar (10,000psi) 700bar (10,000psi) 700bar (10,000psi)
NOMINAL OIL CAPACITY 350cc (21.4in3) 550cc (33.6in3) 1000cc (61.0in3)
USABLE OIL CAPACITY 300.0cc (18.3in3) 580.0cc (35.4in3) 1110.0cc (67.7in3)
OIL VOLUME PER
STROKE
1st 3.62cc (0.221in3) 3.62cc (0.221in3) 3.62cc (0.221in3)
2nd 0.77cc (0.046in3) 0.77cc (0.046in3) 0.77cc (0.046in3)
MAX HANDLE EFFORT 33kgf (72.75lbf) 25kgf (55.12lbf) 21kgf (46.30lbf)
PISTON STROKE 18.0mm (0.71”) 18.0mm (0.71”) 18.0mm (0.71”)

HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL PAGE 6
5. HOW THE HAND PUMPS WORK
1. The control lever is moved to the
advance position to pressurise the
lower/advance port or to the retract
position to pressurise the upper/
retract port.
2. The pump handle is raised, which
creates a vacuum in the piston
chamber which sucks oil from the
reservoir into the chamber.
3. The pump handle is depressed,
which pumps the oil from the
chamber through the outlet port
and into the system to which the
pump is connected.
4. Steps 2 & 3 are repeated, which will
pump oil into the system until the
maximum pressure of
10,000 psi (700 bar) is achieved, at
which point the safety release valve
will open and the oil will cycle back
to the reservoir.
Control lever
Advance
Retract
Advance
Retract

HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL PAGE 7
6. INSTALLATION AND OPERATION
WARNING:
Never attempt to pressurise the pump when the pressure gauge is not
connected or the pump is not connected to a system!
DANGER:
Always check the hydraulic system in which the pump is to be used is rated
for 10,000 psi (700 bar). Over pressurising a hydraulic system will result in
component failure and personal injury!
2. Ensure the hydraulic system you
wish to pressurise has been bled
and is free from air and leaks.
Connect the pump into the system
using the screw connector supplied
with the pump, push the male and
female connectors together fully and
rotate the locking ring clockwise
until fully tight.
WARNING:
Never disconnect the pump
or other components when
the system is pressurised
6.1 HP350SD, HP550SD & HP1000SD
MALE AND FEMALE
CONNECTORS
LOCKING
RING
LOCKING
RING
1. Prior to using the pump the hydraulic
gauge must be tted.
push the male connector on the gauge
and female connector on the gauge
adaptor together fully and rotate the
locking ring counterclockwise until fully
tight.

HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL PAGE 8
3. The HP350SD, HP550SD &
HP1000SD is tted with a control
lever. This enables the operator to
pressurise the advance or retract
hoses.
Pushing the control lever forward
to activate the advance port.
4. Pressurise the advance hose by
raising and depressing the pump
handle until the desired pressure is
indicated on the pressure gauge
N.B. max. pressure 10,000 psi (700
bar)
5. To depressurise the advance hose
move the control lever to the retract
position this will redirect the ow
to the retract hose.
6. Pressurise the retract hose by raising
and depressing the pump handle
with the control lever in the retract
position until the desired pressure is
indicated on the pressure gauge
N.B. max. pressure 10,000 psi (700
bar)
Control lever
Advance
Retract
Advance
Retract
Andere Handbücher für HP350SD
1
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere Equalizer Wasserpumpe Handbücher
Beliebte Wasserpumpe Handbücher anderer Marken

Sykes AmeriPumps
Sykes AmeriPumps GP100M Fehlerbehebungshandbuch

DUROMAX
DUROMAX XP WX Series Bedienungsanleitung

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Bedienungsanleitung

Franklin Electric
Franklin Electric IPS Bedienungsanleitung

Xylem
Xylem e-1532 Series Bedienungsanleitung

Milton Roy
Milton Roy PRIMEROYAL Bedienungsanleitung