ETS NORD NORDcanopy Bedienungsanleitung

NORDcanopy
UV-C Cleaning System Installation Guide

www.etsnord.com
2RDM-064-0722
®NORDcanopy |UV 1.0 installation guide
Table of contents
General 3
Product safety instructions 5
Check your product 5
WARNINGS! 6
System overview 6
1. Installation of the Control Unit 7
2. Installation of UV-C lamps 10
3. Remote Access Device connection 12
4. Installation of the Control Panel 13
5. Electrical connections of Control Unit 15
6. Maintenance 19
Facts about UV and ozone 21

Images are for illustrative purposes.
We reserve the right to make changes. RDT-064-0722 3
®NORDcanopy |UV 1.0 installation guide
General
This guide contains information for the safe installation of an integrated Control Unit into an ETS NORD kitchen
canopy with UV cleaning. Read the guide carefully before installing, setting up or performing maintenance!
Check that the packaged products do not have visible damage. Immediately notify the supplier and manufacturer
of the products of damage or missing components.
12
5
9 13
64
15
21
14
7
171610
83
11
1 – Supply air adjustment plate
2 – Supply air connection
3 – UV control unit
4 – Lighting
5 – Exhaust air adjustment plate
6 – Exhaust air connection
7 – UV lamps
8 – Suspension points
9 – Front panel
10 – Front panel lock
11 – Auxilliary air supply
12 – “AirGrip” air nozzle system
13 – UV shield
14 – UV shield safety switch
15 – HFK grase filters
16 – Airflow measuring nozzle
17 – Grease collection containers

www.etsnord.com
4RDM-064-0722
®NORDcanopy |UV 1.0 installation guide
The UV cleaning system consists of three separate components:
- One or more Control Unit(s)
- UV-C lamp(s) to support the exhaust airflow
- LCD Control Panel
- Remote Access Device*
* Allows the user to access and manage the UV cleaning system remotely, from the LAN or Internet.
The Control Unit packaging includes:
- Control Unit
- Pressure measurement hose (2x30cm)
- Pressure measurement hose (1x1.5m)
- Power cable IEC C13 with plug (3m)
The LCD Control Panel packaging includes:
- Control Panel
- Device address identification stickers
Each kitchen is equipped with one Control Panel, which can provide access to and oversight over up to ten UV
cleaning systems.

Images are for illustrative purposes.
We reserve the right to make changes. RDT-064-0722 5
®NORDcanopy |UV 1.0 installation guide
Product safety instructions
Failure to comply with these instructions or incorrect use of this device may cause serious bodily injury.
The UV cleaning system is designed to treat kitchen exhaust air with UV light and ozone only as described in
this manual.
Use of this UV technology reduces odors and reduces fat, mold and bacteria to water vapor and dry minerals.
ETS NORD AS assumes no liability if the product is not used in accordance with the manufacturer’s instructions
in this guide.
The installation of the Control Unit may only be carried out by persons trained and authorized by ETS NORD in
accordance with international standards and regulations.
It is forbidden to use replacement lamps or any other spare parts that are not supplied by ETS NORD Customer
Service.
Ultraviolet radiation and ozone are harmful to health. Prolonged exposure can cause the following damage:
• Skin rashes and burns
• Eye irritation, retinal burn and loss of vision
• Respiratory irritation and breathing problems
When removing grease filters from a UV-canopy, ensure that the UV system is powered o at the main
electrical closet or safety breaker.
When installing servicing or servicing the lamps, always wear goggles and protective gloves to protect against
quartz fragments in case of UV-C lamp breakage.
Check your product
Make sure that all components are received, matching both the order and delivery confirmation letters. Incorrect
delivery and transport damage must be immediately reported to both the cargo carrier and ETS NORD Customer
Service.
The time for filing a complaint or shipment discrepancy is 5 days after delivery. ETS NORD is not responsible
for defects that have occurred after goods have been handed over to the buyer.
If goods purchased from ETS NORD have defects for which ETS NORD is responsible, ETS NORD will repair
or replace the defective goods. If the goods cannot be repaired or replaced, ETS NORD will refund to the buyer
all fees for such items resulting from the sales contract.
If you have any problems, please contact ETS NORD Customer Service!

www.etsnord.com
6RDM-064-0722
®NORDcanopy |UV 1.0 installation guide
WARNINGS!
System overview
This device emits ultraviolet radiation and ozone!
Prolonged exposure to ozone and ultraviolet radiation can cause bodily injury.
When removing grease filters, always make sure that the UV system is powered o at
the main electrical closet or safety breaker.
Risk of falling!
Make sure installation and service personnel have stable work platforms when installing
the device.
When removing grease filters, always make sure that the UV system is powered o at
the main electrical closet or safety breaker.
Risk of electric shock!
Electrical connections to the system may only be made by an authorized electrician.
Always power o the system before any maintenance work!
Always make sure that the UV system is powered o at the main electrical closet or safety
breaker.
Only original spare parts and UV-C lamps purchased from ETS NORD may be used in
the UV 1.0 Control Unit!
UV-C lamps can be ordered from ETS NORD Customer Service.
7
4
6
5
3
2
1
1 – Control Unit
2 – Light
3 – UV-C lamp
4 – UV shield
5 – UV shield switch
6 – HFK grease filters
7 – LCD Control Panel

Images are for illustrative purposes.
We reserve the right to make changes. RDT-064-0722 7
®NORDcanopy |UV 1.0 installation guide
1. Installation of the Control Unit
*Depending on the size of the kitchen canopy, there may be 1-4 “L” lamp power sockets.
1.1 Opening the front panel
To install the Control Unit, the right supply air panel of the canopy must be removed using a small screwdriver
or Allen wrench, as shown in the picture. Press upward to release the internal latch.
6
2
3
4
1
5
8
9
10
7
1 – UV-C lamp “L” power sockets*
2 – Control Unit fastening clamps
3 – On/O switch
4 – Power socket with automatic circuit breaker for
IEC C13 plug
5 – Control Panel RJ45 socket
6 – Indicator LED
7 – Exhaust pressure measurement nozzle
8 – Ambient pressure measurement nozzle
9 – Remote Access Device RJ45 socket
10 – Input socket (ModBus, building automation I/O)

www.etsnord.com
8RDM-064-0722
®NORDcanopy |UV 1.0 installation guide
1.2 Mounting the Control Unit to the supply chamber
Next, fasten the Control Unit up against the ceiling of the supply chamber using its four fastening clamps.
4x

Images are for illustrative purposes.
We reserve the right to make changes. RDT-064-0722 9
®NORDcanopy |UV 1.0 installation guide
1.3 Installation of pressure measurement hoses
Next, two pressure measurement hoses shall be connected between the nipples protruding from the Control Unit
to their respective nipples on the ceiling of the supply chamber. Connect the rightmost hose to the rightmost
nipple (picture 1). This hose provides the system with the static pressure of the surrounding environment. Attach
the left hose to the left pressure nipple (picture 2). Ensure that these connections are made correctly and that
the hoses are firmly attached to each nipple.
Next, the long exhaust pressure measurement hose must be connected above the canopy. Connect the hose
from the nipple closest to the center of the canopy to the nipple above the exhaust chamber. Ensure that the
hose is firmly attached to each nipple.
NOTE! To prevent dirt or debris from entering the Control Unit or pressure measurement hoses, cap
them o until installation is ready to be performed.
1. 2.

www.etsnord.com
10 RDM-064-0722
®NORDcanopy |UV 1.0 installation guide
2. Installation of UV-C lamps
2.1 Removing UV shield and grease filters
2.2 Mounting UV-C lamps to the exhaust chamber
Carefully attach each UV-C lamp to the ceiling of the exhaust chamber so that the blue plastic part at the ends
of the lamp, not the glass portion, remains between the clamps. Tighten the clamp with its fixing screw.
NOTE! Before installing UV-C lamps, make sure that the system is turned o.
2x
Andere Handbücher für NORDcanopy
5
Inhaltsverzeichnis
Andere ETS NORD Lüfter Handbücher