Ex-Sight.Com EX-CT Bedienungsanleitung

Ex-Sight.Com Ex-CT Compact Thermal Camera
EX-CT
USER MANUAL
Compact Rugged Dual-Sensor PTZ Camera
(CCD & Un-Cooled Thermal IR)

Ex-Sight.Com Ex-CT Compact Thermal Camera
Modification History
Revision
Date of Release
Modified Contents
Ver 1.0
Mar 1st 2012
Official release of first version

Ex-Sight.Com Ex-CT Compact Thermal Camera
i / ii
Thank You for Choosing Our Portable All-Condition Rugged PTZ
Camera!
When you open the box:
Check that the packing and the contents are not visibly damaged. Contact the
retailer immediately if any parts are either missing or damaged.
Make sure if the contents are all included as per the packing list.
Do not attempt to use the device with missing or damaged parts. Send the product
back in its original packing if it is damaged.
The information contained in the document is subject to change without notice.

Ex-Sight.Com Ex-CT Compact Thermal Camera
ii / ii
Contents
SAFETY NOTES 1
ABOUT THE PRODUCT 2
TECHNICAL DATA 6
PREPARATION 8
INSTALLATION 11
OPERATION 15
ANNEX: DIP SWITCH –CAMERA ADDRESS 19

Ex-CT (Compact Thermal) User Manual
1
Safety Notes
The following important notes must be followed carefully to run the camera and
respective accessories in total safety. The camera and relative accessories are called
video system in this section.
Before installing the camera, please read this manual carefully; when installing
please follow instructions of installation indicated in this manual. Please keep this
manual for future use.
The following installation should be performed by qualified service personnel or
system installers in accordance with all local rules.
Before powering on the camera, please check the power voltage carefully. Make
sure that you are using the right power source.
Please put the power cable, video cable and control cable in safe place.
Do not operate the camera beyond the specified temperature and humidity. The
camera’s working temperature range is between -45℃~+65℃. The ambient
humidity range is less than 95﹪.
When transporting, avoid violent shake or force to the camera.
To prevent electric shock, do not remove screws or covers of the camera. There are
no self-serviceable parts inside. Refer to qualified service personnel for servicing.
Video cable and RS485 cable should be far away from other cables. Shielded and
independent wiring is necessary for video and control cables.
Never aim the lens of the camera at the sun or other extremely bright objects.
Otherwise, it may cause damage.
When cleaning the camera, please use soft cloth. If the camera is very dirty, wipe it
off gently with a soft cloth moistened with a weak solution of water and a neutral
kitchen detergent. Wring all liquid from the cloth before wiping the camera, then
wipe off all remaining dirt with a soft, dry cloth. Use lens cleaning paper to clean the
lens.
Do not move the camera module manually. In doing so would result in malfunction
of the camera. Do not hold the camera module when carrying the video camera.
Make sure the camera is far away from area where radiation, X-rays, strong electric
waves, or magnetism is generated

Ex-CT (Compact Thermal) User Manual
2
About The Product
EX-CT series Thermal imaging system camera is designed for important video
surveillance application such as Police, Rescue, Border Patrol, Marine, etc. (fixed and
mobile video surveillance application.) It consists of: thermal imaging sensor, high
resolution zoom module, precise PTZ system, optional damping systems. It ensures
clear view of details under total dark or foggy environment.
Thermal Imaging Sensor
Built-in Un-Cooled αSi thermal imaging sensor, 384×288, provide clear view in total
darkness.
ExView HAD CCD Modules
The 18X/28X/36X SONY ExView HAD CCD modules provide high resolution quality
video effect.
Full Aluminum PTZ Case
The case with high strength is full weather proof, suitable for various tough applications
such as rugged roads, sea, storm weather etc.
New Drive Mechanism
The PTZ camera employs new drive system with high precision and higher holding
torque. It does not generate offset during positioning of Pan and Tilt.
Easy Installation Mounts
The new vacuum and magnetic vacuum can easily fix the PTZ camera firmly onto a
metal surface. Meanwhile user can easily carry the PTZ camera with the handle at the
back side.
1.1. FEATURES
Built-in 382*288 full time high sensitive thermal imager, provider clear view under
total darkness;
Integrated HAD 28X zoom module, 550 TVL, 0.0015 LUX
Aluminum PTZ case with high strength, special Fabrication Processing, full
weather proof;
Fully sealed design, IP index up to IP67, built-in surge and lighting strike protection
device;
Built-in integrated heating and defogging device, working temperature rang -45oC ~

Ex-CT (Compact Thermal) User Manual
3
75oC
3 video outputs: thermal video, zoom module video and complex video;
Precise PTZ system with high precision and higher holding torque, PTZ positioning
precision up to +/-0.050
Detect protocol & Baud rate automatically, soft address supported, convenient for
use;
Optional damping system, for tough applications;
Hidden seamless window wiper with adjustable speed;
Digital image stabilization;
Image flip for stand / ceiling mount;
Video freeze;
Wide Dynamic Range (WDR);
Day/night (ICR);
10.8~28V voltage input;
Auto power-off with low power supply.
1.2. FUNCTIONS
Day/Night Function
The IR cut filter of camera module inside the camera can be removed by sending
special command, so that the camera can change from color to mono. The picture is
clear even if the illumination is as low as 0.01Lux.
Save/Call Preset
Preset function is that dome saves current horizontal angle and title angle of pan/tilt,
zoom and position parameters into memory. When necessary dome calls these
parameters and adjusts Pan/Tilt and camera to that position. User can save and call
presets easily and promptly by using keyboard controller or infrared controller. The
camera supports up to 256 presets.
Zoom control
User can adjust zoom wide or tele by controller and get desired image.
Focus control
System defaults Auto Focus mode, that is, the lens and camera will automatically
adjust the focus to get the best image.
Focus can also be controlled manually from the controller if required. Press Focus Near
or Focus Far key to manually focus. Focus can be manual via keyboard or other

Ex-CT (Compact Thermal) User Manual
4
controller, please refer to control keyboard or other controller operation manual for
detailed operation.
The camera will NOT auto focus in the following status.
Target is not in the center of image.
Targets are in near and far at the same time.
Target is of strong light object. Such as spotlight etc.
Target is behind the glass with water drop or dust.
Target moves too fast.
Large area target such as wall.
Target is too dark or vague.
IRIS control
System defaults Auto IRIS. Camera can adjust immediately according to the alteration
of back ground illumination so that a lightness steady image can be achieved.
You may adjust IRIS by controller to get required image brightness, and call back Auto
IRIS by controlling the joystick.
Auto White Balance
Camera can automatically adjust white balance (WB) according to the alteration of
background lightness to give a true color image.
Back Light Compensation (BLC)
If a bright backlight presents, the subjects in the picture may appear dark or as a
silhouette. Backlight compensation enhances objects in the center of the picture. The
camera uses the center of the picture to adjust the IRIS. If there is a bright light source
outside this area, it will wash out to white. The camera will adjust the IRIS so that the
object in the sensitive area is properly exposed.
Auto Cruise
The preset position is programmed to be recalled in sequence. This feature is called
auto cruise.
Auto, Random and Frame Scan
Auto Scan: Make the camera scan 360° ranging from the current position.
Random Scan: Make the camera scan 360º ranging from the current position, pause at
every 108 º.
Frame Scan: Make the camera scan between two set positions.
For Frame Scan: The zoom at two limits shall be programed the same.

Ex-CT (Compact Thermal) User Manual
5
Image Flip
Enable you to view image easily when PTZ is either installed on roof of a car or is
mounted on the ceiling.

Ex-CT (Compact Thermal) User Manual
6
Technical Data
Digital Zoom
1X, 2X, 4X
Video Display
White / Black
Display Mode
Image Enhanced, Image Flip
Alarm Display
Cursor Display on Over-radiation of IR
Daylight Imaging Camera
Video Sensor
1/4" SONY EXView HAD CCD
Effective Pixel
PAL:752(H)×582(V);NTSC:768(H)×494(V)
Resolution
550 TVL
Video System
PAL/NTSC
Min
Illumination
Color:
0.25 lux (F1.35, 50IRE);
0.16 lux (1/4 sec (NTSC);
1/3 sec (PAL),F1.35, 50IRE);
Mono:
0.0015 lux(1/4 sec (NTSC);
WB
Auto / Manual / ATW / Indoor / Outdoor
Focus
Auto / Manual
IRIS
Auto / Manual / IRIS Priority / Shutter Priority / Brightness
S/N Ratio
Not less than 50 dB
BLC
On / Off
Image
Stabilization
On / Off
DNR
1-5 Steps / Off
Day / Night
Auto / Manual
Optical Zoom
28X
Digital Zoom
12X
Lens
f=3.5 mm (wide) to 98 mm(tele)
F1.35 to F3.7
View Angle
55.8º (wide) to 2.1º (tele)
PTZ
Pan Range
360° Continuous
Inhaltsverzeichnis